This typo is quite common. Fix it and add it to the spelling file so
that checkpatch catches it earlier.
Link: http://lkml.kernel.org/r/20170317011131.6881-2-sboyd@codeaurora.org
Signed-off-by: Stephen Boyd <sboyd@codeaurora.org>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
napi_complete_done() allows to opt-in for gro_flush_timeout,
added back in linux-3.19, commit 3b47d30396
("net: gro: add a per device gro flush timer")
This allows for more efficient GRO aggregation without
sacrifying latencies.
Signed-off-by: Eric Dumazet <edumazet@google.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
As per Wolfgang G, all new drivers should support decreasing state
transition(back-to-error-active). This patch adds this support.
This driver configures the controller to halt on bus-off entry. Hence,
when in error states less than bus off state, the TEC/REC counters
are checked for lower state transition eligibility and action.
Signed-off-by: Ramesh Shanmugasundaram <ramesh.shanmugasundaram@bp.renesas.com>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
The controller can operate in one of the two global modes
- CAN FD only mode (default)
- Classical CAN (CAN2.0) only mode
This patch adds support for Classical CAN only mode. It can be enabled
by defining the optional device tree property "renesas,no-can-fd" of this
node.
Note: R-Car Gen3 h/w manual v0.51E shows bit6 of RSCFDnCFDGCFG as
reserved, which is incorrect. This bit is same as RSCFDnGCFG.
Signed-off-by: Ramesh Shanmugasundaram <ramesh.shanmugasundaram@bp.renesas.com>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
This patch adds support for the CAN FD controller found in Renesas R-Car
SoCs. The controller operates in CAN FD only mode by default.
CAN FD mode supports both Classical CAN & CAN FD frame formats. The
controller supports ISO 11898-1:2015 CAN FD format only.
This controller supports two channels and the driver can enable either
or both of the channels.
Driver uses Rx FIFOs (one per channel) for reception & Common FIFOs (one
per channel) for transmission. Rx filter rules are configured to the
minimum (one per channel) and it accepts Standard, Extended, Data &
Remote Frame combinations.
Note: There are few documentation errors in R-Car Gen3 Hardware User
Manual v0.5E with respect to CAN FD controller. They are listed below:
1. CAN FD interrupt numbers 29 & 30 are listed as per channel
interrupts. However, they are common to both channels (i.e.) they are
global and channel interrupts respectively.
2. CANFD clock is derived from PLL1. This is not documented.
3. CANFD clock is further divided by (1/2) within the CAN FD controller.
This is not documented.
4. The minimum value of NTSEG1 in RSCFDnCFDCmNCFG register is 2 Tq. It
is specified 4 Tq in the manual.
5. The maximum number of message RAM area the controller can use is 3584
bytes. It is specified 10752 bytes in the manual.
Signed-off-by: Ramesh Shanmugasundaram <ramesh.shanmugasundaram@bp.renesas.com>
Acked-by: Rob Herring <robh@kernel.org>
Reviewed-by: Ulrich Hecht <ulrich.hecht+renesas@gmail.com>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>