Set the bridge status of physical ports in the appropriate functions, to
be consistent with LAG join/leave and vPorts joining/leaving bridge.
Also, remove the error messages in these two functions, as we already
emit errors in both the single functions they call.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
It is possible for us to fail when joining or leaving a bridge, so let
the user know about that by returning NOTIFY_BAD, as already done for
LAG join/leave and 802.1D bridges.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
We set PVID to 1 in mlxsw_sp_port_vlan_init(), so we can remove this
statement.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
KASan reported use-after-free for the hwmon structure. So fix this by
using devm_kzalloc and let the core take care about freeing the memory
during device dettach.
Reported-by: Ido Schimmel <idosch@mellanox.com>
Fixes: 89309da39 ("mlxsw: core: Implement temperature hwmon interface")
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Add another sysfs hwmon attribute to expose possibility to reset
temperature sensors history.
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
When creating a VLAN device on top of LAG, we are basically creating a
vPort on top of each of the port netdevs member in the LAG. Therefore,
these vPorts should inherit both the LAG status and LAG ID from the
underlying port netdevs.
In addition, when the VLAN device joins or leaves a bridge each of the
underlying vPorts should know about it and act accordingly. This is
achieved by propagating the VLAN event down to the lower devices.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
When adding or removing FDB records of VLAN devices on top of LAG we
should set the lag_vid parameter to the VLAN ID of the VLAN device. It
is reserved otherwise.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Unicast LAG records in the Switch Filtering Database (SFD) register have
a lag_vid field indicating the VLAN ID in case of vFIDs. This field is
no longer reserved since we are going to add support for VLAN devices on
top of LAG.
Add the lag_vid field to be used by VLAN devies on top of LAG.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
All the member VLAN devices in a bridge need to share the same vFID.
To achieve that, expand the vFID struct to include the associated bridge
device (or lack of) and allow one to lookup a vFID based on a bridge
device.
When joining a bridge, lookup the relevant vFID or create one if none
exists. Next, make the VLAN device use the vFID.
Leaving a bridge can either occur because a user removed the VLAN device
from a bridge or because the VLAN device was deleted by the user. In the
latter case the bridge's teardown sequence is invoked after the hardware
vPort is already gone. Therefore, when unlinking the VLAN device from
the real device, check if the associated vPort is bridged and act
accordingly. The bridge's notification will be ignored in this case.
Note that bridging a VLAN interface with an ordinary port netdev is
currently not supported, but not forbidden. This will be addressed in a
follow-up patchset.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
When a VLAN interface is configured on top of a physical port we should
associate the VLAN device with the matching vPort. Likewise, when it's
removed, we should revert back to the underlying port netdev.
While not a must, this is consistent with port netdevs and also provides
a more accurate error printing via netdev_err() and friends.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
FDB notifications contain the FID and port (or LAG ID) on which the MAC
was learned. In the case of the 802.1Q bridge one can easily derive the
matching VID - as FID equals VID - and generate the appropriate
notification for the software bridge. With VLAN devices this is no
longer the case, as these are associated with a vFID.
Solve that by converting the FID to a vFID and lookup the matching VLAN
device. From that derive the VID and whether learning (and learning
sync) should occur.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
switchdev ops can now be called for VLAN devices and we need to be
prepared for it. Until now they were only called for the port netdev.
Use the newly propagated orig_dev passed as part of the switchdev
attr/obj and determine whether the original device is a VLAN device. If
so, act accordingly, otherwise continue as usual.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
In the Spectrum ASIC - unlike SwitchX-2 - FDB access is done by
specifying FID as parameter and not VID.
Change the relevant variables and parameters names to reflect that.
Note that this was OK up until now, since FID was always equal to VID,
but with the introduction of VLAN interfaces this is no longer the case.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
We previously used only one flood table for packets classified to vFIDs.
However, since we are going to add support for bridges between VLAN
interfaces (mapped to vFIDs) we need to add one more flood table.
That way we can separate the flooding domain of unknown unicast traffic
from all the rest and support flood control (as we do with the 802.1Q
bridge).
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The __mlxsw_sp_port_flood_set function is now used to configure flooding
for both FIDs and vFIDs, so change the parameter name to 'idx' instead
of 'fid'. This is also consistent with hardware documentation.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Up until now we used a 1:1 mapping - based on VID - to map a VLAN
interface to a vFID. However, a different scheme is needed in order to
support bridges between VLAN interfaces, as all the member interfaces -
which can have different VIDs - need to share the same vFID.
Solve that by splitting the vFID range in two:
1. Non-bridged VLAN interfaces
2. Bridged VLAN interfaces
When a VLAN interface is created, assign it the next available vFID in
the first range, unless one already exists for that VID or number of
vFIDs in the range was exceeded. When interface is removed, free the
vFID, unless other interfaces are mapped to it.
To accomplish the above:
1. Store the VID to vFID mapping in a new struct (mlxsw_sp_vfid), which
has a global context and holds a reference count.
2. Create a vPort (dummy in case of bridge SELF invocation) on top of
of the physical port and hold a reference to the associated vFID.
vfid vfid
+-------------+ +-------------+
| vfid | | vfid |
| vid +---> ... | vid |
| nr_vports | | nr_vports |
+------+------+ +------+------+
|
+-----------------------+-------+
| |
vport vport
+-------------+ +-------------+
| ... | | ... |
| *vfid +---> ... | *vfid +---> ...
| ... | | ... |
+------+------+ +------+------+
| |
port port
+-------------+ +-------------+
| ... | | ... |
| vports_list | | vports_list |
| ... | | ... |
+-------------+ +-------------+
swXpY swXpZ
Next patches in the series will add the missing infrastructure for the
second range and transfer vPorts between the two ranges according to the
received notifications.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
When adding support for bridges between VLAN interfaces, we'll introduce
a new entity called a vPort, which is a represntation of the VLAN
interface in the hardware.
The main difference between a vPort and a physical port is that several
FIDs can be bound to the latter, whereas only one (called a vFID) can be
bound to the first.
Therefore, it makes sense to use the same struct to represent the two,
but to only allocate the 'active_vlans' bitmap in case of a physical
port.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Sensor index should be passed instead of 0. For now, this does not make
a difference, since there is so far only one temperature sensor
exposed by HW.
Fixes: 89309da39 ("mlxsw: core: Implement temperature hwmon interface")
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Fix copy & paste error in MTPM unpack helper.
Fixes: 85926f8770 ("mlxsw: reg: Add definition of temperature management registers")
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
We already know "err" is zero so there is no need to check.
Signed-off-by: Dan Carpenter <dan.carpenter@oracle.com>
Acked-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The "err = " assignment is missing here.
Fixes: 0d65fc1304 ('mlxsw: spectrum: Implement LAG port join/leave')
Signed-off-by: Dan Carpenter <dan.carpenter@oracle.com>
Acked-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Better to just warn the user that something really odd is going on and
continue to run.
Suggested-by: Or Gerlitz <gerlitz.or@gmail.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Enabling/disabling TX on a LAG port means enabling/disabling distribution
in our HW.
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Implement FDB offloading for lagged ports, including learning LAG FDB
entries, adding/removing static FDB entries and dumping existing LAG FDB
entries.
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Implement basic procedures for joining/leaving port to/from LAG. That
includes HW setup of collector, core LAG mapping setup.
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
LAG-related records have specific format in SFN register.
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
LAG-related records have specific format in SFD register.
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Add definitions of SLDR, SLCR2, SLCOR registers that are used to
configure LAG.
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Completion queue element for receive queue provides information if the
packet was received via LAG port. Extract this info and pass it along
to core.
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Lower layer (pci) has information if the packet is received via LAG port.
If that is the case, it fills up rx_info accordingly. However upper
layer does not care about lag_id/port_index for received packets so
convert it to local_port before passing it up. For that conversion, lag
mapping array is introduced. Upper layer is responsible for setting up
the mapping according to what is set in HW.
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Add just a stub for now. This allows to pass check in dev_ifsioc,
SIOCADDMULTI and SIOCDELMULTI cases. Teamd is using these to add LACP
slow MAC.
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
ASIC provides access to fans. Implement their exposure to userspace
using hwmon.
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Add definition of MFCR, MFSC and MFSM which provide possibility to
control and monitor fans.
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
ASIC provides access to temperature sensors. Implement their exposure to
userspace using hwmon.
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Add definition of MTCAP and MTMP registers which provide access to
temperature sensors.
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Allow a user to flash the port's LED in order to identify it. This is
achieved by setting the Management LED Control Register (MLCR).
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Add the MLCR register, which controls physical port identification LEDs.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The operation of adding VLANs on a port via switchdev ops can fail and
we need to be prepared for it. If we do not rollback hardware operations
following a failure, hardware and software will remain in an
inconsistent state.
Solve that by adding suitable error paths to __mlxsw_sp_port_vlans_add.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
When adding or deleting VLANs from a bridged port, HW VLAN filters must be
set accordingly. Instead of having the same code in both add and delete
functions, just wrap it in a function and call it with the appropriate
parameters.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Elad Raz <eladr@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
When removing a range of VLANs in which PVID is a member we should use
the correct PVID value instead of some VLAN in the range.
Also, change two print statements to use 'dev' instead of
'mlxsw_sp_port->dev', as it's already used in other print statements in
the function.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Fix a place where checkpatch complains that braces should be used
on all arms of this statement.
Signed-off-by: Or Gerlitz <ogerlitz@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Fixes those places where checkpatch complains that comparisons
should place the constant on the right side of the test.
Signed-off-by: Or Gerlitz <ogerlitz@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The value passed through switchdev attr set is not in jiffies, but in
clock_t, so fix the convert.
Reported-by: Sagi Rotem <sagir@mellanox.com>
Fixes: 56ade8fe3f ("mlxsw: spectrum: Add initial support for Spectrum ASIC")
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The original description was for LAG, so fix it.
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Add or remove a bridged port from the flooding domain of unknown unicast
packets according to user configuration.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
When enabling a range of VLANs on a bridged port we can configure
flooding for these VLANs by one register access instead of calling the
same register for each VLAN. This is accomplished by using the 'range'
field of the Switch Flooding Table Register (SFTR).
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
It is a flag anyway, so move it to existing u8 flag and don't waste mem.
Fix the flags to be in single u8 on the way.
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>