mirror of
https://github.com/AuxXxilium/linux_dsm_epyc7002.git
synced 2024-12-15 08:26:40 +07:00
ARM64: dts: marvell: armada-cp110: Add registers clock for the trng node
This extra clock is needed to access the registers of the harware RNG used on CP110 component of the Armada 7K/8K SoCs. This follow the changes already made in the binding documentation (as well as in the driver): "hwrng: omap - Fix clock resource by adding a register clock" Signed-off-by: Gregory CLEMENT <gregory.clement@bootlin.com>
This commit is contained in:
parent
f1ebfab99d
commit
cc4d5aed82
@ -375,7 +375,9 @@ CP110_LABEL(trng): trng@760000 {
|
||||
"inside-secure,safexcel-eip76";
|
||||
reg = <0x760000 0x7d>;
|
||||
interrupts = <ICU_GRP_NSR 95 IRQ_TYPE_LEVEL_HIGH>;
|
||||
clocks = <&CP110_LABEL(clk) 1 25>;
|
||||
clock-names = "core", "reg";
|
||||
clocks = <&CP110_LABEL(clk) 1 25>,
|
||||
<&CP110_LABEL(clk) 1 17>;
|
||||
status = "okay";
|
||||
};
|
||||
|
||||
|