mirror of
https://github.com/AuxXxilium/linux_dsm_epyc7002.git
synced 2024-12-19 09:36:49 +07:00
ca2618b5d5
During a short period when the bus voltage is switched from 3.3v to 1.8v, (to enumerate UHS mode), the mmc module is disabled and the mmc IO lines are kept in a state according to the programmed pad mux pull type. According to 4.2.4.2 Timing to Switch Signal Voltage in "SD Specifications Part 1 Physical Layer Specification Version 5.00 February 22, 2016", the host should hold CLK low for at least 5ms. In order to keep the card line low during voltage switch, the pad mux of mmc1_clk line should be configured to pull down. Add a new pinctrl group for clock line without pullup to be used in boards where mmc1_clk line is not connected to an external pullup. Signed-off-by: Kishon Vijay Abraham I <kishon@ti.com> Signed-off-by: Tony Lindgren <tony@atomide.com>
20 lines
771 B
Plaintext
20 lines
771 B
Plaintext
// SPDX-License-Identifier: GPL-2.0
|
|
/*
|
|
* MMC IOdelay values for TI's DRA7xx SoCs.
|
|
* Copyright (C) 2018 Texas Instruments
|
|
* Author: Kishon Vijay Abraham I <kishon@ti.com>
|
|
*/
|
|
|
|
&dra7_pmx_core {
|
|
mmc1_pins_default_no_clk_pu: mmc1_pins_default_no_clk_pu {
|
|
pinctrl-single,pins = <
|
|
DRA7XX_CORE_IOPAD(0x3754, PIN_INPUT_PULLDOWN | MUX_MODE0) /* mmc1_clk.clk */
|
|
DRA7XX_CORE_IOPAD(0x3758, PIN_INPUT_PULLUP | MUX_MODE0) /* mmc1_cmd.cmd */
|
|
DRA7XX_CORE_IOPAD(0x375c, PIN_INPUT_PULLUP | MUX_MODE0) /* mmc1_dat0.dat0 */
|
|
DRA7XX_CORE_IOPAD(0x3760, PIN_INPUT_PULLUP | MUX_MODE0) /* mmc1_dat1.dat1 */
|
|
DRA7XX_CORE_IOPAD(0x3764, PIN_INPUT_PULLUP | MUX_MODE0) /* mmc1_dat2.dat2 */
|
|
DRA7XX_CORE_IOPAD(0x3768, PIN_INPUT_PULLUP | MUX_MODE0) /* mmc1_dat3.dat3 */
|
|
>;
|
|
};
|
|
};
|