.. SPDX-License-Identifier: GPL-2.0-only
|
|
|
|
Broadcom BCM54140 Quad SGMII/QSGMII PHY
|
|
=======================================
|
|
|
|
Supported chips:
|
|
|
|
* Broadcom BCM54140
|
|
|
|
Datasheet: not public
|
|
|
|
Author: Michael Walle <michael@walle.cc>
|
|
|
|
Description
|
|
-----------
|
|
|
|
The Broadcom BCM54140 is a Quad SGMII/QSGMII PHY which supports monitoring
|
|
its die temperature as well as two analog voltages.
|
|
|
|
The AVDDL is a 1.0V analogue voltage, the AVDDH is a 3.3V analogue voltage.
|
|
Both voltages and the temperature are measured in a round-robin fashion.
|
|
|
|
Sysfs entries
|
|
-------------
|
|
|
|
The following attributes are supported.
|
|
|
|
======================= ========================================================
|
|
in0_label "AVDDL"
|
|
in0_input Measured AVDDL voltage.
|
|
in0_min Minimum AVDDL voltage.
|
|
in0_max Maximum AVDDL voltage.
|
|
in0_alarm AVDDL voltage alarm.
|
|
|
|
in1_label "AVDDH"
|
|
in1_input Measured AVDDH voltage.
|
|
in1_min Minimum AVDDH voltage.
|
|
in1_max Maximum AVDDH voltage.
|
|
in1_alarm AVDDH voltage alarm.
|
|
|
|
temp1_input Die temperature.
|
|
temp1_min Minimum die temperature.
|
|
temp1_max Maximum die temperature.
|
|