mirror of
https://github.com/AuxXxilium/linux_dsm_epyc7002.git
synced 2025-02-06 05:55:21 +07:00
e995163cdc
MAC filters for VFs were being programmed with 0 for the VLAN value when there was no VLAN assigned. This is incorrect and actually assigns the VF to VLAN 0. Instead, we must use -1 to indicate that no VLAN is in use. This change programs the filters correctly and gets rid of a bogus error message when setting a port VLAN on an active VF. Change-ID: Ica9a9906d768405377ff3308e27f7d0b5b2ea96e Signed-off-by: Mitch Williams <mitch.a.williams@intel.com> Tested-by: Jim Young <james.m.young@intel.com> Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com> |
||
---|---|---|
.. | ||
e1000 | ||
e1000e | ||
fm10k | ||
i40e | ||
i40evf | ||
igb | ||
igbvf | ||
ixgb | ||
ixgbe | ||
ixgbevf | ||
e100.c | ||
Kconfig | ||
Makefile |