linux_dsm_epyc7002/drivers/clocksource/timer-riscv.c
Christoph Hellwig 4f9bbcefa1 riscv: add support for MMIO access to the timer registers
When running in M-mode we can't use the SBI to set the timer, and
don't have access to the time CSR as that usually is emulated by
M-mode.  Instead provide code that directly accesses the MMIO for
the timer.

Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Anup Patel <anup@brainfault.org>
Acked-by: Thomas Gleixner <tglx@linutronix.de> # for drivers/clocksource
[paul.walmsley@sifive.com: updated to apply; fixed checkpatch
 issue; timex.h now includes asm/mmio.h to resolve header file
 problems]
Signed-off-by: Paul Walmsley <paul.walmsley@sifive.com>
2019-11-13 14:10:40 -08:00

139 lines
3.5 KiB
C

// SPDX-License-Identifier: GPL-2.0
/*
* Copyright (C) 2012 Regents of the University of California
* Copyright (C) 2017 SiFive
*
* All RISC-V systems have a timer attached to every hart. These timers can
* either be read from the "time" and "timeh" CSRs, and can use the SBI to
* setup events, or directly accessed using MMIO registers.
*/
#include <linux/clocksource.h>
#include <linux/clockchips.h>
#include <linux/cpu.h>
#include <linux/delay.h>
#include <linux/irq.h>
#include <linux/sched_clock.h>
#include <linux/io-64-nonatomic-lo-hi.h>
#include <asm/smp.h>
#include <asm/sbi.h>
u64 __iomem *riscv_time_cmp;
u64 __iomem *riscv_time_val;
static inline void mmio_set_timer(u64 val)
{
void __iomem *r;
r = riscv_time_cmp + cpuid_to_hartid_map(smp_processor_id());
writeq_relaxed(val, r);
}
static int riscv_clock_next_event(unsigned long delta,
struct clock_event_device *ce)
{
csr_set(CSR_IE, IE_TIE);
if (IS_ENABLED(CONFIG_RISCV_SBI))
sbi_set_timer(get_cycles64() + delta);
else
mmio_set_timer(get_cycles64() + delta);
return 0;
}
static DEFINE_PER_CPU(struct clock_event_device, riscv_clock_event) = {
.name = "riscv_timer_clockevent",
.features = CLOCK_EVT_FEAT_ONESHOT,
.rating = 100,
.set_next_event = riscv_clock_next_event,
};
/*
* It is guaranteed that all the timers across all the harts are synchronized
* within one tick of each other, so while this could technically go
* backwards when hopping between CPUs, practically it won't happen.
*/
static unsigned long long riscv_clocksource_rdtime(struct clocksource *cs)
{
return get_cycles64();
}
static u64 riscv_sched_clock(void)
{
return get_cycles64();
}
static struct clocksource riscv_clocksource = {
.name = "riscv_clocksource",
.rating = 300,
.mask = CLOCKSOURCE_MASK(64),
.flags = CLOCK_SOURCE_IS_CONTINUOUS,
.read = riscv_clocksource_rdtime,
};
static int riscv_timer_starting_cpu(unsigned int cpu)
{
struct clock_event_device *ce = per_cpu_ptr(&riscv_clock_event, cpu);
ce->cpumask = cpumask_of(cpu);
clockevents_config_and_register(ce, riscv_timebase, 100, 0x7fffffff);
csr_set(CSR_IE, IE_TIE);
return 0;
}
static int riscv_timer_dying_cpu(unsigned int cpu)
{
csr_clear(CSR_IE, IE_TIE);
return 0;
}
/* called directly from the low-level interrupt handler */
void riscv_timer_interrupt(void)
{
struct clock_event_device *evdev = this_cpu_ptr(&riscv_clock_event);
csr_clear(CSR_IE, IE_TIE);
evdev->event_handler(evdev);
}
static int __init riscv_timer_init_dt(struct device_node *n)
{
int cpuid, hartid, error;
hartid = riscv_of_processor_hartid(n);
if (hartid < 0) {
pr_warn("Not valid hartid for node [%pOF] error = [%d]\n",
n, hartid);
return hartid;
}
cpuid = riscv_hartid_to_cpuid(hartid);
if (cpuid < 0) {
pr_warn("Invalid cpuid for hartid [%d]\n", hartid);
return cpuid;
}
if (cpuid != smp_processor_id())
return 0;
pr_info("%s: Registering clocksource cpuid [%d] hartid [%d]\n",
__func__, cpuid, hartid);
error = clocksource_register_hz(&riscv_clocksource, riscv_timebase);
if (error) {
pr_err("RISCV timer register failed [%d] for cpu = [%d]\n",
error, cpuid);
return error;
}
sched_clock_register(riscv_sched_clock, 64, riscv_timebase);
error = cpuhp_setup_state(CPUHP_AP_RISCV_TIMER_STARTING,
"clockevents/riscv/timer:starting",
riscv_timer_starting_cpu, riscv_timer_dying_cpu);
if (error)
pr_err("cpu hp setup state failed for RISCV timer [%d]\n",
error);
return error;
}
TIMER_OF_DECLARE(riscv_timer, "riscv", riscv_timer_init_dt);