Because the label is different between CPs, the full path of a node is unique. However, when referring to the end of the path only (the node name), this name is not unique anymore. The *thermal_zone_of_sensor_register() functions of the thermal core present this limitation and prevent having a thermal-zone per CP. Add a macro to make the distinction between node names to solve this situation. Signed-off-by: Miquel Raynal <miquel.raynal@bootlin.com> Signed-off-by: Gregory CLEMENT <gregory.clement@bootlin.com>
12 lines
406 B
Plaintext
12 lines
406 B
Plaintext
// SPDX-License-Identifier: (GPL-2.0+ OR MIT)
|
|
/*
|
|
* Copyright (C) 2016 Marvell Technology Group Ltd.
|
|
*/
|
|
|
|
/* Common definitions used by Armada 7K/8K DTs */
|
|
#define PASTER(x, y) x ## y
|
|
#define EVALUATOR(x, y) PASTER(x, y)
|
|
#define CP110_LABEL(name) EVALUATOR(CP110_NAME, EVALUATOR(_, name))
|
|
#define CP110_NODE_NAME(name) EVALUATOR(CP110_NAME, EVALUATOR(-, name))
|
|
#define ADDRESSIFY(addr) EVALUATOR(0x, addr)
|