Major cleanup of all s390 inline assemblies. They now have a common coding style. Quite a few have been shortened, mainly by using register asm variables. Use of the EX_TABLE macro helps as well. The atomic ops, bit ops and locking inlines new use the Q-constraint if a newer gcc is used. That results in slightly better code. Thanks to Christian Borntraeger for proof reading the changes. Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
91 lines
2.2 KiB
C
91 lines
2.2 KiB
C
/*
|
|
* include/asm-s390/appldata.h
|
|
*
|
|
* Copyright (C) IBM Corp. 2006
|
|
*
|
|
* Author(s): Melissa Howland <melissah@us.ibm.com>
|
|
*/
|
|
|
|
#ifndef _ASM_S390_APPLDATA_H
|
|
#define _ASM_S390_APPLDATA_H
|
|
|
|
#include <asm/io.h>
|
|
|
|
#ifndef CONFIG_64BIT
|
|
|
|
#define APPLDATA_START_INTERVAL_REC 0x00 /* Function codes for */
|
|
#define APPLDATA_STOP_REC 0x01 /* DIAG 0xDC */
|
|
#define APPLDATA_GEN_EVENT_REC 0x02
|
|
#define APPLDATA_START_CONFIG_REC 0x03
|
|
|
|
/*
|
|
* Parameter list for DIAGNOSE X'DC'
|
|
*/
|
|
struct appldata_parameter_list {
|
|
u16 diag; /* The DIAGNOSE code X'00DC' */
|
|
u8 function; /* The function code for the DIAGNOSE */
|
|
u8 parlist_length; /* Length of the parameter list */
|
|
u32 product_id_addr; /* Address of the 16-byte product ID */
|
|
u16 reserved;
|
|
u16 buffer_length; /* Length of the application data buffer */
|
|
u32 buffer_addr; /* Address of the application data buffer */
|
|
} __attribute__ ((packed));
|
|
|
|
#else /* CONFIG_64BIT */
|
|
|
|
#define APPLDATA_START_INTERVAL_REC 0x80
|
|
#define APPLDATA_STOP_REC 0x81
|
|
#define APPLDATA_GEN_EVENT_REC 0x82
|
|
#define APPLDATA_START_CONFIG_REC 0x83
|
|
|
|
/*
|
|
* Parameter list for DIAGNOSE X'DC'
|
|
*/
|
|
struct appldata_parameter_list {
|
|
u16 diag;
|
|
u8 function;
|
|
u8 parlist_length;
|
|
u32 unused01;
|
|
u16 reserved;
|
|
u16 buffer_length;
|
|
u32 unused02;
|
|
u64 product_id_addr;
|
|
u64 buffer_addr;
|
|
} __attribute__ ((packed));
|
|
|
|
#endif /* CONFIG_64BIT */
|
|
|
|
struct appldata_product_id {
|
|
char prod_nr[7]; /* product number */
|
|
u16 prod_fn; /* product function */
|
|
u8 record_nr; /* record number */
|
|
u16 version_nr; /* version */
|
|
u16 release_nr; /* release */
|
|
u16 mod_lvl; /* modification level */
|
|
} __attribute__ ((packed));
|
|
|
|
static inline int appldata_asm(struct appldata_product_id *id,
|
|
unsigned short fn, void *buffer,
|
|
unsigned short length)
|
|
{
|
|
struct appldata_parameter_list parm_list;
|
|
int ry;
|
|
|
|
if (!MACHINE_IS_VM)
|
|
return -ENOSYS;
|
|
parm_list.diag = 0xdc;
|
|
parm_list.function = fn;
|
|
parm_list.parlist_length = sizeof(parm_list);
|
|
parm_list.buffer_length = length;
|
|
parm_list.product_id_addr = (unsigned long) id;
|
|
parm_list.buffer_addr = virt_to_phys(buffer);
|
|
asm volatile(
|
|
" diag %1,%0,0xdc"
|
|
: "=d" (ry)
|
|
: "d" (&parm_list), "m" (parm_list), "m" (*id)
|
|
: "cc");
|
|
return ry;
|
|
}
|
|
|
|