mirror of
https://github.com/AuxXxilium/linux_dsm_epyc7002.git
synced 2024-12-22 00:20:15 +07:00
8ea229511e
This extends the sysfs interface for thermal cooling devices and exposes some pretty useful statistics. These statistics have proven to be quite useful specially while doing benchmarks related to the task scheduler, where we want to make sure that nothing has disrupted the test, specially the cooling device which may have put constraints on the CPUs. The information exposed here tells us to what extent the CPUs were constrained by the thermal framework. The write-only "reset" file is used to reset the statistics. The read-only "time_in_state_ms" file shows the time (in msec) spent by the device in the respective cooling states, and it prints one line per cooling state. The read-only "total_trans" file shows single positive integer value showing the total number of cooling state transitions the device has gone through since the time the cooling device is registered or the time when statistics were reset last. The read-only "trans_table" file shows a two dimensional matrix, where an entry <i,j> (row i, column j) represents the number of transitions from State_i to State_j. This is how the directory structure looks like for a single cooling device: $ ls -R /sys/class/thermal/cooling_device0/ /sys/class/thermal/cooling_device0/: cur_state max_state power stats subsystem type uevent /sys/class/thermal/cooling_device0/power: autosuspend_delay_ms runtime_active_time runtime_suspended_time control runtime_status /sys/class/thermal/cooling_device0/stats: reset time_in_state_ms total_trans trans_table This is tested on ARM 64-bit Hisilicon hikey620 board running Ubuntu and ARM 64-bit Hisilicon hikey960 board running Android. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Zhang Rui <rui.zhang@intel.com>
493 lines
16 KiB
Plaintext
493 lines
16 KiB
Plaintext
#
|
|
# Generic thermal sysfs drivers configuration
|
|
#
|
|
|
|
menuconfig THERMAL
|
|
tristate "Generic Thermal sysfs driver"
|
|
help
|
|
Generic Thermal Sysfs driver offers a generic mechanism for
|
|
thermal management. Usually it's made up of one or more thermal
|
|
zone and cooling device.
|
|
Each thermal zone contains its own temperature, trip points,
|
|
cooling devices.
|
|
All platforms with ACPI thermal support can use this driver.
|
|
If you want this support, you should say Y or M here.
|
|
|
|
if THERMAL
|
|
|
|
config THERMAL_STATISTICS
|
|
bool "Thermal state transition statistics"
|
|
help
|
|
Export thermal state transition statistics information through sysfs.
|
|
|
|
If in doubt, say N.
|
|
|
|
config THERMAL_EMERGENCY_POWEROFF_DELAY_MS
|
|
int "Emergency poweroff delay in milli-seconds"
|
|
depends on THERMAL
|
|
default 0
|
|
help
|
|
Thermal subsystem will issue a graceful shutdown when
|
|
critical temperatures are reached using orderly_poweroff(). In
|
|
case of failure of an orderly_poweroff(), the thermal emergency
|
|
poweroff kicks in after a delay has elapsed and shuts down the system.
|
|
This config is number of milliseconds to delay before emergency
|
|
poweroff kicks in. Similarly to the critical trip point,
|
|
the delay should be carefully profiled so as to give adequate
|
|
time for orderly_poweroff() to finish on regular execution.
|
|
If set to 0 emergency poweroff will not be supported.
|
|
|
|
In doubt, leave as 0.
|
|
|
|
config THERMAL_HWMON
|
|
bool
|
|
prompt "Expose thermal sensors as hwmon device"
|
|
depends on HWMON=y || HWMON=THERMAL
|
|
default y
|
|
help
|
|
In case a sensor is registered with the thermal
|
|
framework, this option will also register it
|
|
as a hwmon. The sensor will then have the common
|
|
hwmon sysfs interface.
|
|
|
|
Say 'Y' here if you want all thermal sensors to
|
|
have hwmon sysfs interface too.
|
|
|
|
config THERMAL_OF
|
|
bool
|
|
prompt "APIs to parse thermal data out of device tree"
|
|
depends on OF
|
|
default y
|
|
help
|
|
This options provides helpers to add the support to
|
|
read and parse thermal data definitions out of the
|
|
device tree blob.
|
|
|
|
Say 'Y' here if you need to build thermal infrastructure
|
|
based on device tree.
|
|
|
|
config THERMAL_WRITABLE_TRIPS
|
|
bool "Enable writable trip points"
|
|
help
|
|
This option allows the system integrator to choose whether
|
|
trip temperatures can be changed from userspace. The
|
|
writable trips need to be specified when setting up the
|
|
thermal zone but the choice here takes precedence.
|
|
|
|
Say 'Y' here if you would like to allow userspace tools to
|
|
change trip temperatures.
|
|
|
|
choice
|
|
prompt "Default Thermal governor"
|
|
default THERMAL_DEFAULT_GOV_STEP_WISE
|
|
help
|
|
This option sets which thermal governor shall be loaded at
|
|
startup. If in doubt, select 'step_wise'.
|
|
|
|
config THERMAL_DEFAULT_GOV_STEP_WISE
|
|
bool "step_wise"
|
|
select THERMAL_GOV_STEP_WISE
|
|
help
|
|
Use the step_wise governor as default. This throttles the
|
|
devices one step at a time.
|
|
|
|
config THERMAL_DEFAULT_GOV_FAIR_SHARE
|
|
bool "fair_share"
|
|
select THERMAL_GOV_FAIR_SHARE
|
|
help
|
|
Use the fair_share governor as default. This throttles the
|
|
devices based on their 'contribution' to a zone. The
|
|
contribution should be provided through platform data.
|
|
|
|
config THERMAL_DEFAULT_GOV_USER_SPACE
|
|
bool "user_space"
|
|
select THERMAL_GOV_USER_SPACE
|
|
help
|
|
Select this if you want to let the user space manage the
|
|
platform thermals.
|
|
|
|
config THERMAL_DEFAULT_GOV_POWER_ALLOCATOR
|
|
bool "power_allocator"
|
|
select THERMAL_GOV_POWER_ALLOCATOR
|
|
help
|
|
Select this if you want to control temperature based on
|
|
system and device power allocation. This governor can only
|
|
operate on cooling devices that implement the power API.
|
|
|
|
endchoice
|
|
|
|
config THERMAL_GOV_FAIR_SHARE
|
|
bool "Fair-share thermal governor"
|
|
help
|
|
Enable this to manage platform thermals using fair-share governor.
|
|
|
|
config THERMAL_GOV_STEP_WISE
|
|
bool "Step_wise thermal governor"
|
|
help
|
|
Enable this to manage platform thermals using a simple linear
|
|
governor.
|
|
|
|
config THERMAL_GOV_BANG_BANG
|
|
bool "Bang Bang thermal governor"
|
|
default n
|
|
help
|
|
Enable this to manage platform thermals using bang bang governor.
|
|
|
|
Say 'Y' here if you want to use two point temperature regulation
|
|
used for fans without throttling. Some fan drivers depend on this
|
|
governor to be enabled (e.g. acerhdf).
|
|
|
|
config THERMAL_GOV_USER_SPACE
|
|
bool "User_space thermal governor"
|
|
help
|
|
Enable this to let the user space manage the platform thermals.
|
|
|
|
config THERMAL_GOV_POWER_ALLOCATOR
|
|
bool "Power allocator thermal governor"
|
|
help
|
|
Enable this to manage platform thermals by dynamically
|
|
allocating and limiting power to devices.
|
|
|
|
config CPU_THERMAL
|
|
bool "generic cpu cooling support"
|
|
depends on CPU_FREQ
|
|
depends on THERMAL_OF
|
|
help
|
|
This implements the generic cpu cooling mechanism through frequency
|
|
reduction. An ACPI version of this already exists
|
|
(drivers/acpi/processor_thermal.c).
|
|
This will be useful for platforms using the generic thermal interface
|
|
and not the ACPI interface.
|
|
|
|
If you want this support, you should say Y here.
|
|
|
|
config CLOCK_THERMAL
|
|
bool "Generic clock cooling support"
|
|
depends on COMMON_CLK
|
|
depends on PM_OPP
|
|
help
|
|
This entry implements the generic clock cooling mechanism through
|
|
frequency clipping. Typically used to cool off co-processors. The
|
|
device that is configured to use this cooling mechanism will be
|
|
controlled to reduce clock frequency whenever temperature is high.
|
|
|
|
config DEVFREQ_THERMAL
|
|
bool "Generic device cooling support"
|
|
depends on PM_DEVFREQ
|
|
depends on PM_OPP
|
|
help
|
|
This implements the generic devfreq cooling mechanism through
|
|
frequency reduction for devices using devfreq.
|
|
|
|
This will throttle the device by limiting the maximum allowed DVFS
|
|
frequency corresponding to the cooling level.
|
|
|
|
In order to use the power extensions of the cooling device,
|
|
devfreq should use the simple_ondemand governor.
|
|
|
|
If you want this support, you should say Y here.
|
|
|
|
config THERMAL_EMULATION
|
|
bool "Thermal emulation mode support"
|
|
help
|
|
Enable this option to make a emul_temp sysfs node in thermal zone
|
|
directory to support temperature emulation. With emulation sysfs node,
|
|
user can manually input temperature and test the different trip
|
|
threshold behaviour for simulation purpose.
|
|
|
|
WARNING: Be careful while enabling this option on production systems,
|
|
because userland can easily disable the thermal policy by simply
|
|
flooding this sysfs node with low temperature values.
|
|
|
|
config HISI_THERMAL
|
|
tristate "Hisilicon thermal driver"
|
|
depends on ARCH_HISI || COMPILE_TEST
|
|
depends on HAS_IOMEM
|
|
depends on OF
|
|
default y
|
|
help
|
|
Enable this to plug hisilicon's thermal sensor driver into the Linux
|
|
thermal framework. cpufreq is used as the cooling device to throttle
|
|
CPUs when the passive trip is crossed.
|
|
|
|
config IMX_THERMAL
|
|
tristate "Temperature sensor driver for Freescale i.MX SoCs"
|
|
depends on (ARCH_MXC && CPU_THERMAL) || COMPILE_TEST
|
|
depends on NVMEM || !NVMEM
|
|
depends on MFD_SYSCON
|
|
depends on OF
|
|
help
|
|
Support for Temperature Monitor (TEMPMON) found on Freescale i.MX SoCs.
|
|
It supports one critical trip point and one passive trip point. The
|
|
cpufreq is used as the cooling device to throttle CPUs when the
|
|
passive trip is crossed.
|
|
|
|
config MAX77620_THERMAL
|
|
tristate "Temperature sensor driver for Maxim MAX77620 PMIC"
|
|
depends on MFD_MAX77620
|
|
depends on OF
|
|
help
|
|
Support for die junction temperature warning alarm for Maxim
|
|
Semiconductor PMIC MAX77620 device. Device generates two alarm
|
|
interrupts when PMIC die temperature cross the threshold of
|
|
120 degC and 140 degC.
|
|
|
|
config QORIQ_THERMAL
|
|
tristate "QorIQ Thermal Monitoring Unit"
|
|
depends on THERMAL_OF
|
|
depends on HAS_IOMEM
|
|
help
|
|
Support for Thermal Monitoring Unit (TMU) found on QorIQ platforms.
|
|
It supports one critical trip point and one passive trip point. The
|
|
cpufreq is used as the cooling device to throttle CPUs when the
|
|
passive trip is crossed.
|
|
|
|
config SPEAR_THERMAL
|
|
tristate "SPEAr thermal sensor driver"
|
|
depends on PLAT_SPEAR || COMPILE_TEST
|
|
depends on HAS_IOMEM
|
|
depends on OF
|
|
help
|
|
Enable this to plug the SPEAr thermal sensor driver into the Linux
|
|
thermal framework.
|
|
|
|
config ROCKCHIP_THERMAL
|
|
tristate "Rockchip thermal driver"
|
|
depends on ARCH_ROCKCHIP || COMPILE_TEST
|
|
depends on RESET_CONTROLLER
|
|
depends on HAS_IOMEM
|
|
help
|
|
Rockchip thermal driver provides support for Temperature sensor
|
|
ADC (TS-ADC) found on Rockchip SoCs. It supports one critical
|
|
trip point. Cpufreq is used as the cooling device and will throttle
|
|
CPUs when the Temperature crosses the passive trip point.
|
|
|
|
config RCAR_THERMAL
|
|
tristate "Renesas R-Car thermal driver"
|
|
depends on ARCH_RENESAS || COMPILE_TEST
|
|
depends on HAS_IOMEM
|
|
help
|
|
Enable this to plug the R-Car thermal sensor driver into the Linux
|
|
thermal framework.
|
|
|
|
config RCAR_GEN3_THERMAL
|
|
tristate "Renesas R-Car Gen3 thermal driver"
|
|
depends on ARCH_RENESAS || COMPILE_TEST
|
|
depends on HAS_IOMEM
|
|
depends on OF
|
|
help
|
|
Enable this to plug the R-Car Gen3 thermal sensor driver into the Linux
|
|
thermal framework.
|
|
|
|
config KIRKWOOD_THERMAL
|
|
tristate "Temperature sensor on Marvell Kirkwood SoCs"
|
|
depends on MACH_KIRKWOOD || COMPILE_TEST
|
|
depends on HAS_IOMEM
|
|
depends on OF
|
|
help
|
|
Support for the Kirkwood thermal sensor driver into the Linux thermal
|
|
framework. Only kirkwood 88F6282 and 88F6283 have this sensor.
|
|
|
|
config DOVE_THERMAL
|
|
tristate "Temperature sensor on Marvell Dove SoCs"
|
|
depends on ARCH_DOVE || MACH_DOVE || COMPILE_TEST
|
|
depends on HAS_IOMEM
|
|
depends on OF
|
|
help
|
|
Support for the Dove thermal sensor driver in the Linux thermal
|
|
framework.
|
|
|
|
config DB8500_THERMAL
|
|
tristate "DB8500 thermal management"
|
|
depends on MFD_DB8500_PRCMU
|
|
default y
|
|
help
|
|
Adds DB8500 thermal management implementation according to the thermal
|
|
management framework. A thermal zone with several trip points will be
|
|
created. Cooling devices can be bound to the trip points to cool this
|
|
thermal zone if trip points reached.
|
|
|
|
config ARMADA_THERMAL
|
|
tristate "Marvell EBU Armada SoCs thermal management"
|
|
depends on ARCH_MVEBU || COMPILE_TEST
|
|
depends on HAS_IOMEM
|
|
depends on OF
|
|
help
|
|
Enable this option if you want to have support for thermal management
|
|
controller present in Marvell EBU Armada SoCs (370,375,XP,38x,7K,8K).
|
|
|
|
config DA9062_THERMAL
|
|
tristate "DA9062/DA9061 Dialog Semiconductor thermal driver"
|
|
depends on MFD_DA9062 || COMPILE_TEST
|
|
depends on OF
|
|
help
|
|
Enable this for the Dialog Semiconductor thermal sensor driver.
|
|
This will report PMIC junction over-temperature for one thermal trip
|
|
zone.
|
|
Compatible with the DA9062 and DA9061 PMICs.
|
|
|
|
config INTEL_POWERCLAMP
|
|
tristate "Intel PowerClamp idle injection driver"
|
|
depends on THERMAL
|
|
depends on X86
|
|
depends on CPU_SUP_INTEL
|
|
help
|
|
Enable this to enable Intel PowerClamp idle injection driver. This
|
|
enforce idle time which results in more package C-state residency. The
|
|
user interface is exposed via generic thermal framework.
|
|
|
|
config X86_PKG_TEMP_THERMAL
|
|
tristate "X86 package temperature thermal driver"
|
|
depends on X86_THERMAL_VECTOR
|
|
select THERMAL_GOV_USER_SPACE
|
|
select THERMAL_WRITABLE_TRIPS
|
|
default m
|
|
help
|
|
Enable this to register CPU digital sensor for package temperature as
|
|
thermal zone. Each package will have its own thermal zone. There are
|
|
two trip points which can be set by user to get notifications via thermal
|
|
notification methods.
|
|
|
|
config INTEL_SOC_DTS_IOSF_CORE
|
|
tristate
|
|
depends on X86 && PCI
|
|
select IOSF_MBI
|
|
help
|
|
This is becoming a common feature for Intel SoCs to expose the additional
|
|
digital temperature sensors (DTSs) using side band interface (IOSF). This
|
|
implements the common set of helper functions to register, get temperature
|
|
and get/set thresholds on DTSs.
|
|
|
|
config INTEL_SOC_DTS_THERMAL
|
|
tristate "Intel SoCs DTS thermal driver"
|
|
depends on X86 && PCI
|
|
select INTEL_SOC_DTS_IOSF_CORE
|
|
select THERMAL_WRITABLE_TRIPS
|
|
help
|
|
Enable this to register Intel SoCs (e.g. Bay Trail) platform digital
|
|
temperature sensor (DTS). These SoCs have two additional DTSs in
|
|
addition to DTSs on CPU cores. Each DTS will be registered as a
|
|
thermal zone. There are two trip points. One of the trip point can
|
|
be set by user mode programs to get notifications via Linux thermal
|
|
notification methods.The other trip is a critical trip point, which
|
|
was set by the driver based on the TJ MAX temperature.
|
|
|
|
config INTEL_QUARK_DTS_THERMAL
|
|
tristate "Intel Quark DTS thermal driver"
|
|
depends on X86_INTEL_QUARK
|
|
help
|
|
Enable this to register Intel Quark SoC (e.g. X1000) platform digital
|
|
temperature sensor (DTS). For X1000 SoC, it has one on-die DTS.
|
|
The DTS will be registered as a thermal zone. There are two trip points:
|
|
hot & critical. The critical trip point default value is set by
|
|
underlying BIOS/Firmware.
|
|
|
|
menu "ACPI INT340X thermal drivers"
|
|
source drivers/thermal/int340x_thermal/Kconfig
|
|
endmenu
|
|
|
|
config INTEL_BXT_PMIC_THERMAL
|
|
tristate "Intel Broxton PMIC thermal driver"
|
|
depends on X86 && INTEL_SOC_PMIC_BXTWC && REGMAP
|
|
help
|
|
Select this driver for Intel Broxton PMIC with ADC channels monitoring
|
|
system temperature measurements and alerts.
|
|
This driver is used for monitoring the ADC channels of PMIC and handles
|
|
the alert trip point interrupts and notifies the thermal framework with
|
|
the trip point and temperature details of the zone.
|
|
|
|
config INTEL_PCH_THERMAL
|
|
tristate "Intel PCH Thermal Reporting Driver"
|
|
depends on X86 && PCI
|
|
help
|
|
Enable this to support thermal reporting on certain intel PCHs.
|
|
Thermal reporting device will provide temperature reading,
|
|
programmable trip points and other information.
|
|
|
|
config MTK_THERMAL
|
|
tristate "Temperature sensor driver for mediatek SoCs"
|
|
depends on ARCH_MEDIATEK || COMPILE_TEST
|
|
depends on HAS_IOMEM
|
|
depends on NVMEM || NVMEM=n
|
|
depends on RESET_CONTROLLER
|
|
default y
|
|
help
|
|
Enable this option if you want to have support for thermal management
|
|
controller present in Mediatek SoCs
|
|
|
|
menu "Broadcom thermal drivers"
|
|
depends on ARCH_BCM || ARCH_BRCMSTB || ARCH_BCM2835 || COMPILE_TEST
|
|
source "drivers/thermal/broadcom/Kconfig"
|
|
endmenu
|
|
|
|
menu "Texas Instruments thermal drivers"
|
|
depends on ARCH_HAS_BANDGAP || COMPILE_TEST
|
|
depends on HAS_IOMEM
|
|
source "drivers/thermal/ti-soc-thermal/Kconfig"
|
|
endmenu
|
|
|
|
menu "Samsung thermal drivers"
|
|
depends on ARCH_EXYNOS || COMPILE_TEST
|
|
source "drivers/thermal/samsung/Kconfig"
|
|
endmenu
|
|
|
|
menu "STMicroelectronics thermal drivers"
|
|
depends on ARCH_STI && OF
|
|
source "drivers/thermal/st/Kconfig"
|
|
endmenu
|
|
|
|
config TANGO_THERMAL
|
|
tristate "Tango thermal management"
|
|
depends on ARCH_TANGO || COMPILE_TEST
|
|
help
|
|
Enable the Tango thermal driver, which supports the primitive
|
|
temperature sensor embedded in Tango chips since the SMP8758.
|
|
This sensor only generates a 1-bit signal to indicate whether
|
|
the die temperature exceeds a programmable threshold.
|
|
|
|
source "drivers/thermal/tegra/Kconfig"
|
|
|
|
config QCOM_SPMI_TEMP_ALARM
|
|
tristate "Qualcomm SPMI PMIC Temperature Alarm"
|
|
depends on OF && SPMI && IIO
|
|
select REGMAP_SPMI
|
|
help
|
|
This enables a thermal sysfs driver for Qualcomm plug-and-play (QPNP)
|
|
PMIC devices. It shows up in sysfs as a thermal sensor with multiple
|
|
trip points. The temperature reported by the thermal sensor reflects the
|
|
real time die temperature if an ADC is present or an estimate of the
|
|
temperature based upon the over temperature stage value.
|
|
|
|
config GENERIC_ADC_THERMAL
|
|
tristate "Generic ADC based thermal sensor"
|
|
depends on IIO
|
|
help
|
|
This enabled a thermal sysfs driver for the temperature sensor
|
|
which is connected to the General Purpose ADC. The ADC channel
|
|
is read via IIO framework and the channel information is provided
|
|
to this driver. This driver reports the temperature by reading ADC
|
|
channel and converts it to temperature based on lookup table.
|
|
|
|
menu "Qualcomm thermal drivers"
|
|
depends on (ARCH_QCOM && OF) || COMPILE_TEST
|
|
source "drivers/thermal/qcom/Kconfig"
|
|
endmenu
|
|
|
|
config ZX2967_THERMAL
|
|
tristate "Thermal sensors on zx2967 SoC"
|
|
depends on ARCH_ZX || COMPILE_TEST
|
|
help
|
|
Enable the zx2967 thermal sensors driver, which supports
|
|
the primitive temperature sensor embedded in zx2967 SoCs.
|
|
This sensor generates the real time die temperature.
|
|
|
|
config UNIPHIER_THERMAL
|
|
tristate "Socionext UniPhier thermal driver"
|
|
depends on ARCH_UNIPHIER || COMPILE_TEST
|
|
depends on THERMAL_OF && MFD_SYSCON
|
|
help
|
|
Enable this to plug in UniPhier on-chip PVT thermal driver into the
|
|
thermal framework. The driver supports CPU thermal zone temperature
|
|
reporting and a couple of trip points.
|
|
endif
|