mirror of
https://github.com/AuxXxilium/linux_dsm_epyc7002.git
synced 2024-11-25 05:30:54 +07:00
3bc45af81d
The hip06 D03 and hip07 D05 boards have different reference clock frequencies for the SAS controller. Register PHY_CTRL needs to be programmed differently according to this frequency, so add support for this. The default register setting in PHY_CTRL is for 50MHz, so only update this register when the refclk frequency is 66MHz. For ACPI we expect the _RST handler to set the correct value for PHY_CTRL (we're forced to take different approach for DT and ACPI as ACPI does not support fixed-clock device). Signed-off-by: John Garry <john.garry@huawei.com> Signed-off-by: Xiang Chen <chenxiang66@hisilicon.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com> |
||
---|---|---|
.. | ||
hisi_sas_main.c | ||
hisi_sas_v1_hw.c | ||
hisi_sas_v2_hw.c | ||
hisi_sas.h | ||
Kconfig | ||
Makefile |