Enable operation of the TI OPT3001 light sensor without having an interrupt line available to connect the INT pin to. In this operation mode, we issue a conversion request and simply wait for the conversion time available as timeout value, determined from integration time configuration and the worst-case time given in the data sheet (sect. 6.5, table on p. 5): short integration time (100ms): 110ms + 3ms = 113ms long integration time (800ms): 880ms + 3ms = 883ms This change is transparent as behaviour defaults to using the interrupt method if an interrupt no. is configured via device tree. Interrupt-less operation mode is performed when no valid interrupt no. is given. Signed-off-by: Alexander Koch <mail@alexanderkoch.net> Signed-off-by: Michael Hornung <mhornung.linux@gmail.com> Tested-by: Andreas Dannenberg <dannenberg@ti.com> Signed-off-by: Jonathan Cameron <jic23@kernel.org> |
||
---|---|---|
.. | ||