mirror of
https://github.com/AuxXxilium/linux_dsm_epyc7002.git
synced 2024-12-02 13:36:41 +07:00
a71dc65d30
This patch performs the switch to the new template mechanism by modifying the functions ima_alloc_init_template(), ima_measurements_show() and ima_ascii_measurements_show(). The old function ima_template_show() was removed as it is no longer needed. Also, if the template descriptor used to generate a measurement entry is not 'ima', the whole length of field data stored for an entry is provided before the data itself through the binary_runtime_measurement interface. Changelog: - unnecessary to use strncmp() (Mimi Zohar) - create new variable 'field' in ima_alloc_init_template() (Roberto Sassu) - use GFP_NOFS flag in ima_alloc_init_template() (Roberto Sassu) - new variable 'num_fields' in ima_store_template() (Roberto Sassu, proposed by Mimi Zohar) - rename ima_calc_buffer_hash/template_hash() to ima_calc_field_array_hash(), something more generic (Mimi, requested by Dmitry) - sparse error fix - Fengguang Wu - fix lindent warnings - always include the field length in the template data length - include the template field length variable size in the template data length - include both the template field data and field length in the template digest calculation. Simplifies verifying the template digest. (Mimi) Signed-off-by: Roberto Sassu <roberto.sassu@polito.it> Signed-off-by: Mimi Zohar <zohar@linux.vnet.ibm.com> |
||
---|---|---|
.. | ||
evm | ||
ima | ||
digsig_asymmetric.c | ||
digsig.c | ||
iint.c | ||
integrity_audit.c | ||
integrity.h | ||
Kconfig | ||
Makefile |