When testing CAN write floods on Altera's CycloneV, the first 2 bytes are sometimes 0x00, 0x00 or corrupted instead of the values sent. Also observed bytes 4 & 5 were corrupted in some cases. The D_CAN Data registers are 32 bits and changing from 16 bit writes to 32 bit writes fixes the problem. Testing performed on Altera CycloneV (D_CAN). Requesting tests on other C_CAN & D_CAN platforms. Reported-by: Richard Andrysek <richard.andrysek@gomtec.de> Signed-off-by: Thor Thayer <tthayer@opensource.altera.com> Cc: <stable@vger.kernel.org> Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de> |
||
---|---|---|
.. | ||