linux_dsm_epyc7002/Documentation/hwmon/max6639.rst
Mauro Carvalho Chehab 7ebd8b66dd docs: hwmon: Add an index file and rename docs to *.rst
Now that all files were converted to ReST format, rename them
and add an index.

Signed-off-by: Mauro Carvalho Chehab <mchehab+samsung@kernel.org>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2019-04-17 10:37:23 -07:00

56 lines
2.3 KiB
ReStructuredText

Kernel driver max6639
=====================
Supported chips:
* Maxim MAX6639
Prefix: 'max6639'
Addresses scanned: I2C 0x2c, 0x2e, 0x2f
Datasheet: http://pdfserv.maxim-ic.com/en/ds/MAX6639.pdf
Authors:
- He Changqing <hechangqing@semptian.com>
- Roland Stigge <stigge@antcom.de>
Description
-----------
This driver implements support for the Maxim MAX6639. This chip is a 2-channel
temperature monitor with dual PWM fan speed controller. It can monitor its own
temperature and one external diode-connected transistor or two external
diode-connected transistors.
The following device attributes are implemented via sysfs:
====================== ==== ===================================================
Attribute R/W Contents
====================== ==== ===================================================
temp1_input R Temperature channel 1 input (0..150 C)
temp2_input R Temperature channel 2 input (0..150 C)
temp1_fault R Temperature channel 1 diode fault
temp2_fault R Temperature channel 2 diode fault
temp1_max RW Set THERM temperature for input 1
(in C, see datasheet)
temp2_max RW Set THERM temperature for input 2
temp1_crit RW Set ALERT temperature for input 1
temp2_crit RW Set ALERT temperature for input 2
temp1_emergency RW Set OT temperature for input 1
(in C, see datasheet)
temp2_emergency RW Set OT temperature for input 2
pwm1 RW Fan 1 target duty cycle (0..255)
pwm2 RW Fan 2 target duty cycle (0..255)
fan1_input R TACH1 fan tachometer input (in RPM)
fan2_input R TACH2 fan tachometer input (in RPM)
fan1_fault R Fan 1 fault
fan2_fault R Fan 2 fault
temp1_max_alarm R Alarm on THERM temperature on channel 1
temp2_max_alarm R Alarm on THERM temperature on channel 2
temp1_crit_alarm R Alarm on ALERT temperature on channel 1
temp2_crit_alarm R Alarm on ALERT temperature on channel 2
temp1_emergency_alarm R Alarm on OT temperature on channel 1
temp2_emergency_alarm R Alarm on OT temperature on channel 2
====================== ==== ===================================================