mirror of
https://github.com/AuxXxilium/linux_dsm_epyc7002.git
synced 2024-12-23 06:43:06 +07:00
48536c9195
Commit f6edb53c49
converted the probe to
a CPU wide event first (pid == -1). For kernels that do not support
the PERF_FLAG_FD_CLOEXEC flag the probe fails with EINVAL. Since this
errno is not handled pid is not reset to 0 and the subsequent use of
pid = -1 as an argument brings in an additional failure path if
perf_event_paranoid > 0:
$ perf record -- sleep 1
perf_event_open(..., 0) failed unexpectedly with error 13 (Permission denied)
[ perf record: Woken up 1 times to write data ]
[ perf record: Captured and wrote 0.007 MB /tmp/perf.data (11 samples) ]
Also, ensure the fd of the confirmation check is closed and comment why
pid = -1 is used.
Needs to go to 3.18 stable tree as well.
Signed-off-by: Adrian Hunter <adrian.hunter@intel.com>
Based-on-patch-by: David Ahern <david.ahern@oracle.com>
Acked-by: David Ahern <david.ahern@oracle.com>
Cc: David Ahern <dsahern@gmail.com>
Link: http://lkml.kernel.org/r/54EC610C.8000403@intel.com
Cc: stable@vger.kernel.org # v3.18+
Signed-off-by: Arnaldo Carvalho de Melo <acme@redhat.com>
87 lines
1.7 KiB
C
87 lines
1.7 KiB
C
#include <sched.h>
|
|
#include "util.h"
|
|
#include "../perf.h"
|
|
#include "cloexec.h"
|
|
#include "asm/bug.h"
|
|
#include "debug.h"
|
|
|
|
static unsigned long flag = PERF_FLAG_FD_CLOEXEC;
|
|
|
|
static int perf_flag_probe(void)
|
|
{
|
|
/* use 'safest' configuration as used in perf_evsel__fallback() */
|
|
struct perf_event_attr attr = {
|
|
.type = PERF_TYPE_SOFTWARE,
|
|
.config = PERF_COUNT_SW_CPU_CLOCK,
|
|
.exclude_kernel = 1,
|
|
};
|
|
int fd;
|
|
int err;
|
|
int cpu;
|
|
pid_t pid = -1;
|
|
char sbuf[STRERR_BUFSIZE];
|
|
|
|
cpu = sched_getcpu();
|
|
if (cpu < 0)
|
|
cpu = 0;
|
|
|
|
/*
|
|
* Using -1 for the pid is a workaround to avoid gratuitous jump label
|
|
* changes.
|
|
*/
|
|
while (1) {
|
|
/* check cloexec flag */
|
|
fd = sys_perf_event_open(&attr, pid, cpu, -1,
|
|
PERF_FLAG_FD_CLOEXEC);
|
|
if (fd < 0 && pid == -1 && errno == EACCES) {
|
|
pid = 0;
|
|
continue;
|
|
}
|
|
break;
|
|
}
|
|
err = errno;
|
|
|
|
if (fd >= 0) {
|
|
close(fd);
|
|
return 1;
|
|
}
|
|
|
|
WARN_ONCE(err != EINVAL && err != EBUSY,
|
|
"perf_event_open(..., PERF_FLAG_FD_CLOEXEC) failed with unexpected error %d (%s)\n",
|
|
err, strerror_r(err, sbuf, sizeof(sbuf)));
|
|
|
|
/* not supported, confirm error related to PERF_FLAG_FD_CLOEXEC */
|
|
while (1) {
|
|
fd = sys_perf_event_open(&attr, pid, cpu, -1, 0);
|
|
if (fd < 0 && pid == -1 && errno == EACCES) {
|
|
pid = 0;
|
|
continue;
|
|
}
|
|
break;
|
|
}
|
|
err = errno;
|
|
|
|
if (fd >= 0)
|
|
close(fd);
|
|
|
|
if (WARN_ONCE(fd < 0 && err != EBUSY,
|
|
"perf_event_open(..., 0) failed unexpectedly with error %d (%s)\n",
|
|
err, strerror_r(err, sbuf, sizeof(sbuf))))
|
|
return -1;
|
|
|
|
return 0;
|
|
}
|
|
|
|
unsigned long perf_event_open_cloexec_flag(void)
|
|
{
|
|
static bool probed;
|
|
|
|
if (!probed) {
|
|
if (perf_flag_probe() <= 0)
|
|
flag = 0;
|
|
probed = true;
|
|
}
|
|
|
|
return flag;
|
|
}
|