Binding for the axi-clkgen clock generator
This binding uses the common clock binding[1].
[1] Documentation/devicetree/bindings/clock/clock-bindings.txt
Required properties:
- compatible : shall be "adi,axi-clkgen-1.00.a" or "adi,axi-clkgen-2.00.a".
- #clock-cells : from common clock binding; Should always be set to 0.
- reg : Address and length of the axi-clkgen register set.
- clocks : Phandle and clock specifier for the parent clock(s). This must
either reference one clock if only the first clock input is connected or two
if both clock inputs are connected. For the later case the clock connected
to the first input must be specified first.
Optional properties:
- clock-output-names : From common clock binding.
Example:
clock@ff000000 {
compatible = "adi,axi-clkgen";
#clock-cells = <0>;
reg = <0xff000000 0x1000>;
clocks = <&osc 1>;
};