mirror of
https://github.com/AuxXxilium/linux_dsm_epyc7002.git
synced 2024-11-25 07:20:53 +07:00
34aed73df3
Some sources for adc battery information provide only inaccurate results where the read value differs from the real value with positive and negative offsets. For such sources it can be more accurate to collect two or more value sample and use the average of all collected values. This patch adds pdata options volt_samples, current_samples and backup_volt_samples to specifiy the number of samples to collect, reads the specified number of samples and calculates the average of those. For unset sample-number-values a default of 1 is assumed. Signed-off-by: Heiko Stuebner <heiko@sntech.de> Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
42 lines
932 B
C
42 lines
932 B
C
#ifndef _S3C_ADC_BATTERY_H
|
|
#define _S3C_ADC_BATTERY_H
|
|
|
|
struct s3c_adc_bat_thresh {
|
|
int volt; /* mV */
|
|
int cur; /* mA */
|
|
int level; /* percent */
|
|
};
|
|
|
|
struct s3c_adc_bat_pdata {
|
|
int (*init)(void);
|
|
void (*exit)(void);
|
|
void (*enable_charger)(void);
|
|
void (*disable_charger)(void);
|
|
|
|
int gpio_charge_finished;
|
|
int gpio_inverted;
|
|
|
|
const struct s3c_adc_bat_thresh *lut_noac;
|
|
unsigned int lut_noac_cnt;
|
|
const struct s3c_adc_bat_thresh *lut_acin;
|
|
unsigned int lut_acin_cnt;
|
|
|
|
const unsigned int volt_channel;
|
|
const unsigned int current_channel;
|
|
const unsigned int backup_volt_channel;
|
|
|
|
const unsigned int volt_samples;
|
|
const unsigned int current_samples;
|
|
const unsigned int backup_volt_samples;
|
|
|
|
const unsigned int volt_mult;
|
|
const unsigned int current_mult;
|
|
const unsigned int backup_volt_mult;
|
|
const unsigned int internal_impedance;
|
|
|
|
const unsigned int backup_volt_max;
|
|
const unsigned int backup_volt_min;
|
|
};
|
|
|
|
#endif
|