For TI power management chip TPS40422, READ_TEMPERATURE_2 command is supported on page 1 of the chip, but the original driver(pmbus.c) only tried to detect this command on page 0, this will lead to a result that the temperature sensor in page 1 couldn't be detected. This change is to isolate the tps40422 driver from pmbus.c into a solo front-end driver. Signed-off-by: Zhu Laiwen <richard.zhu@nsn.com> [Guenter Roeck: Dropped unnecessary license text (fixes checkpatch warning)] Signed-off-by: Guenter Roeck <linux@roeck-us.net>
134 lines
3.8 KiB
Plaintext
134 lines
3.8 KiB
Plaintext
#
|
|
# PMBus chip drivers configuration
|
|
#
|
|
|
|
menuconfig PMBUS
|
|
tristate "PMBus support"
|
|
depends on I2C
|
|
default n
|
|
help
|
|
Say yes here if you want to enable PMBus support.
|
|
|
|
This driver can also be built as a module. If so, the module will
|
|
be called pmbus_core.
|
|
|
|
if PMBUS
|
|
|
|
config SENSORS_PMBUS
|
|
tristate "Generic PMBus devices"
|
|
default y
|
|
help
|
|
If you say yes here you get hardware monitoring support for generic
|
|
PMBus devices, including but not limited to ADP4000, BMR453, BMR454,
|
|
MDT040, NCP4200, NCP4208, PDT003, PDT006, PDT012, UDT020, and TPS40400.
|
|
|
|
This driver can also be built as a module. If so, the module will
|
|
be called pmbus.
|
|
|
|
config SENSORS_ADM1275
|
|
tristate "Analog Devices ADM1275 and compatibles"
|
|
default n
|
|
help
|
|
If you say yes here you get hardware monitoring support for Analog
|
|
Devices ADM1075, ADM1275, and ADM1276 Hot-Swap Controller and Digital
|
|
Power Monitors.
|
|
|
|
This driver can also be built as a module. If so, the module will
|
|
be called adm1275.
|
|
|
|
config SENSORS_LM25066
|
|
tristate "National Semiconductor LM25066 and compatibles"
|
|
default n
|
|
help
|
|
If you say yes here you get hardware monitoring support for National
|
|
Semiconductor LM25056, LM25066, LM5064, and LM5066.
|
|
|
|
This driver can also be built as a module. If so, the module will
|
|
be called lm25066.
|
|
|
|
config SENSORS_LTC2978
|
|
tristate "Linear Technologies LTC2974, LTC2978, LTC3880, and LTC3883"
|
|
default n
|
|
help
|
|
If you say yes here you get hardware monitoring support for Linear
|
|
Technology LTC2974, LTC2978, LTC3880, and LTC3883.
|
|
|
|
This driver can also be built as a module. If so, the module will
|
|
be called ltc2978.
|
|
|
|
config SENSORS_MAX16064
|
|
tristate "Maxim MAX16064"
|
|
default n
|
|
help
|
|
If you say yes here you get hardware monitoring support for Maxim
|
|
MAX16064.
|
|
|
|
This driver can also be built as a module. If so, the module will
|
|
be called max16064.
|
|
|
|
config SENSORS_MAX34440
|
|
tristate "Maxim MAX34440 and compatibles"
|
|
default n
|
|
help
|
|
If you say yes here you get hardware monitoring support for Maxim
|
|
MAX34440, MAX34441, MAX34446, MAX34460, and MAX34461.
|
|
|
|
This driver can also be built as a module. If so, the module will
|
|
be called max34440.
|
|
|
|
config SENSORS_MAX8688
|
|
tristate "Maxim MAX8688"
|
|
default n
|
|
help
|
|
If you say yes here you get hardware monitoring support for Maxim
|
|
MAX8688.
|
|
|
|
This driver can also be built as a module. If so, the module will
|
|
be called max8688.
|
|
|
|
config SENSORS_TPS40422
|
|
tristate "TI TPS40422"
|
|
default n
|
|
help
|
|
If you say yes here you get hardware monitoring support for TI
|
|
TPS40422.
|
|
|
|
This driver can also be built as a module. If so, the module will
|
|
be called tps40422.
|
|
|
|
config SENSORS_UCD9000
|
|
tristate "TI UCD90120, UCD90124, UCD9090, UCD90910"
|
|
default n
|
|
help
|
|
If you say yes here you get hardware monitoring support for TI
|
|
UCD90120, UCD90124, UCD9090, UCD90910 Sequencer and System Health
|
|
Controllers.
|
|
|
|
This driver can also be built as a module. If so, the module will
|
|
be called ucd9000.
|
|
|
|
config SENSORS_UCD9200
|
|
tristate "TI UCD9220, UCD9222, UCD9224, UCD9240, UCD9244, UCD9246, UCD9248"
|
|
default n
|
|
help
|
|
If you say yes here you get hardware monitoring support for TI
|
|
UCD9220, UCD9222, UCD9224, UCD9240, UCD9244, UCD9246, and UCD9248
|
|
Digital PWM System Controllers.
|
|
|
|
This driver can also be built as a module. If so, the module will
|
|
be called ucd9200.
|
|
|
|
config SENSORS_ZL6100
|
|
tristate "Intersil ZL6100 and compatibles"
|
|
default n
|
|
help
|
|
If you say yes here you get hardware monitoring support for Intersil
|
|
ZL2004, ZL2005, ZL2006, ZL2008, ZL2105, ZL2106, ZL6100, ZL6105,
|
|
ZL9101M, and ZL9117M Digital DC/DC Controllers, as well as for
|
|
Ericsson BMR450, BMR451, BMR462, BMR463, and BMR464.
|
|
|
|
This driver can also be built as a module. If so, the module will
|
|
be called zl6100.
|
|
|
|
endif # PMBUS
|