mirror of
https://github.com/AuxXxilium/linux_dsm_epyc7002.git
synced 2024-12-16 10:48:17 +07:00
7717cbec17
i2400mu_bus_bm_wait_for_ack() invokes usb_get_urb(), which increases the refcount of the "notif_urb". When i2400mu_bus_bm_wait_for_ack() returns, local variable "notif_urb" becomes invalid, so the refcount should be decreased to keep refcount balanced. The issue happens in all paths of i2400mu_bus_bm_wait_for_ack(), which forget to decrease the refcnt increased by usb_get_urb(), causing a refcnt leak. Fix this issue by calling usb_put_urb() before the i2400mu_bus_bm_wait_for_ack() returns. Signed-off-by: Xiyu Yang <xiyuyang19@fudan.edu.cn> Signed-off-by: Xin Tan <tanxin.ctf@gmail.com> Signed-off-by: David S. Miller <davem@davemloft.net> |
||
---|---|---|
.. | ||
i2400m | ||
Kconfig | ||
Makefile |