mirror of
https://github.com/AuxXxilium/linux_dsm_epyc7002.git
synced 2024-11-26 02:20:53 +07:00
cb8011ad53
NetXen: 1G/10G Ethernet Driver updates - Temparature monitoring and device control - Memory footprint reduction - Driver changes to support newer version of firmware Signed-off-by: Amit S. Kale <amitkale@netxen.com> netxen_nic.h | 165 ++++++++++++++++++++++++++++++++-- netxen_nic_ethtool.c | 89 ++++++++++++------ netxen_nic_hdr.h | 71 +++++++++++++- netxen_nic_hw.c | 206 +++++++++++++++++++++++++++++-------------- netxen_nic_hw.h | 8 + netxen_nic_init.c | 239 +++++++++++++++++++++++++++++++++++++++++--------- netxen_nic_ioctl.h | 12 +- netxen_nic_isr.c | 54 +++++------ netxen_nic_main.c | 121 +++++++++++++++++-------- netxen_nic_niu.c | 172 +++++++++++++++++++++++++++-------- netxen_nic_phan_reg.h | 24 ++++- 11 files changed, 891 insertions(+), 270 deletions(-) Signed-off-by: Jeff Garzik <jeff@garzik.org>
895 lines
23 KiB
C
895 lines
23 KiB
C
/*
|
|
* Copyright (C) 2003 - 2006 NetXen, Inc.
|
|
* All rights reserved.
|
|
*
|
|
* This program is free software; you can redistribute it and/or
|
|
* modify it under the terms of the GNU General Public License
|
|
* as published by the Free Software Foundation; either version 2
|
|
* of the License, or (at your option) any later version.
|
|
*
|
|
* This program is distributed in the hope that it will be useful, but
|
|
* WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
* GNU General Public License for more details.
|
|
*
|
|
* You should have received a copy of the GNU General Public License
|
|
* along with this program; if not, write to the Free Software
|
|
* Foundation, Inc., 59 Temple Place - Suite 330, Boston,
|
|
* MA 02111-1307, USA.
|
|
*
|
|
* The full GNU General Public License is included in this distribution
|
|
* in the file called LICENSE.
|
|
*
|
|
* Contact Information:
|
|
* info@netxen.com
|
|
* NetXen,
|
|
* 3965 Freedom Circle, Fourth floor,
|
|
* Santa Clara, CA 95054
|
|
*
|
|
*
|
|
* Provides access to the Network Interface Unit h/w block.
|
|
*
|
|
*/
|
|
|
|
#include "netxen_nic.h"
|
|
|
|
#define NETXEN_GB_MAC_SOFT_RESET 0x80000000
|
|
#define NETXEN_GB_MAC_RESET_PROT_BLK 0x000F0000
|
|
#define NETXEN_GB_MAC_ENABLE_TX_RX 0x00000005
|
|
#define NETXEN_GB_MAC_PAUSED_FRMS 0x00000020
|
|
|
|
static long phy_lock_timeout = 100000000;
|
|
|
|
static inline int phy_lock(void)
|
|
{
|
|
int i;
|
|
int done = 0, timeout = 0;
|
|
|
|
while (!done) {
|
|
done = readl((void __iomem *)NETXEN_PCIE_REG(PCIE_SEM3_LOCK));
|
|
if (done == 1)
|
|
break;
|
|
if (timeout >= phy_lock_timeout) {
|
|
return -1;
|
|
}
|
|
timeout++;
|
|
if (!in_atomic())
|
|
schedule();
|
|
else {
|
|
for (i = 0; i < 20; i++)
|
|
cpu_relax();
|
|
}
|
|
}
|
|
|
|
writel(NETXEN_PHY_LOCK_ID, (void __iomem *)PHY_LOCK_DRIVER);
|
|
return 0;
|
|
}
|
|
|
|
static inline int phy_unlock(void)
|
|
{
|
|
readl((void __iomem *)NETXEN_PCIE_REG(PCIE_SEM3_UNLOCK));
|
|
return 0;
|
|
}
|
|
|
|
/*
|
|
* netxen_niu_gbe_phy_read - read a register from the GbE PHY via
|
|
* mii management interface.
|
|
*
|
|
* Note: The MII management interface goes through port 0.
|
|
* Individual phys are addressed as follows:
|
|
* @param phy [15:8] phy id
|
|
* @param reg [7:0] register number
|
|
*
|
|
* @returns 0 on success
|
|
* -1 on error
|
|
*
|
|
*/
|
|
int netxen_niu_gbe_phy_read(struct netxen_adapter *adapter, long phy,
|
|
long reg, __le32 * readval)
|
|
{
|
|
long timeout = 0;
|
|
long result = 0;
|
|
long restore = 0;
|
|
__le32 address;
|
|
__le32 command;
|
|
__le32 status;
|
|
__le32 mac_cfg0;
|
|
|
|
if (phy_lock() != 0) {
|
|
return -1;
|
|
}
|
|
|
|
/*
|
|
* MII mgmt all goes through port 0 MAC interface,
|
|
* so it cannot be in reset
|
|
*/
|
|
|
|
if (netxen_nic_hw_read_wx(adapter, NETXEN_NIU_GB_MAC_CONFIG_0(0),
|
|
&mac_cfg0, 4))
|
|
return -EIO;
|
|
if (netxen_gb_get_soft_reset(mac_cfg0)) {
|
|
__le32 temp;
|
|
temp = 0;
|
|
netxen_gb_tx_reset_pb(temp);
|
|
netxen_gb_rx_reset_pb(temp);
|
|
netxen_gb_tx_reset_mac(temp);
|
|
netxen_gb_rx_reset_mac(temp);
|
|
if (netxen_nic_hw_write_wx(adapter,
|
|
NETXEN_NIU_GB_MAC_CONFIG_0(0),
|
|
&temp, 4))
|
|
return -EIO;
|
|
restore = 1;
|
|
}
|
|
|
|
address = 0;
|
|
netxen_gb_mii_mgmt_reg_addr(address, reg);
|
|
netxen_gb_mii_mgmt_phy_addr(address, phy);
|
|
if (netxen_nic_hw_write_wx(adapter, NETXEN_NIU_GB_MII_MGMT_ADDR(0),
|
|
&address, 4))
|
|
return -EIO;
|
|
command = 0; /* turn off any prior activity */
|
|
if (netxen_nic_hw_write_wx(adapter, NETXEN_NIU_GB_MII_MGMT_COMMAND(0),
|
|
&command, 4))
|
|
return -EIO;
|
|
/* send read command */
|
|
netxen_gb_mii_mgmt_set_read_cycle(command);
|
|
if (netxen_nic_hw_write_wx(adapter, NETXEN_NIU_GB_MII_MGMT_COMMAND(0),
|
|
&command, 4))
|
|
return -EIO;
|
|
|
|
status = 0;
|
|
do {
|
|
if (netxen_nic_hw_read_wx(adapter,
|
|
NETXEN_NIU_GB_MII_MGMT_INDICATE(0),
|
|
&status, 4))
|
|
return -EIO;
|
|
timeout++;
|
|
} while ((netxen_get_gb_mii_mgmt_busy(status)
|
|
|| netxen_get_gb_mii_mgmt_notvalid(status))
|
|
&& (timeout++ < NETXEN_NIU_PHY_WAITMAX));
|
|
|
|
if (timeout < NETXEN_NIU_PHY_WAITMAX) {
|
|
if (netxen_nic_hw_read_wx(adapter,
|
|
NETXEN_NIU_GB_MII_MGMT_STATUS(0),
|
|
readval, 4))
|
|
return -EIO;
|
|
result = 0;
|
|
} else
|
|
result = -1;
|
|
|
|
if (restore)
|
|
if (netxen_nic_hw_write_wx(adapter,
|
|
NETXEN_NIU_GB_MAC_CONFIG_0(0),
|
|
&mac_cfg0, 4))
|
|
return -EIO;
|
|
phy_unlock();
|
|
return result;
|
|
}
|
|
|
|
/*
|
|
* netxen_niu_gbe_phy_write - write a register to the GbE PHY via
|
|
* mii management interface.
|
|
*
|
|
* Note: The MII management interface goes through port 0.
|
|
* Individual phys are addressed as follows:
|
|
* @param phy [15:8] phy id
|
|
* @param reg [7:0] register number
|
|
*
|
|
* @returns 0 on success
|
|
* -1 on error
|
|
*
|
|
*/
|
|
int netxen_niu_gbe_phy_write(struct netxen_adapter *adapter,
|
|
long phy, long reg, __le32 val)
|
|
{
|
|
long timeout = 0;
|
|
long result = 0;
|
|
long restore = 0;
|
|
__le32 address;
|
|
__le32 command;
|
|
__le32 status;
|
|
__le32 mac_cfg0;
|
|
|
|
/*
|
|
* MII mgmt all goes through port 0 MAC interface, so it
|
|
* cannot be in reset
|
|
*/
|
|
|
|
if (netxen_nic_hw_read_wx(adapter, NETXEN_NIU_GB_MAC_CONFIG_0(0),
|
|
&mac_cfg0, 4))
|
|
return -EIO;
|
|
if (netxen_gb_get_soft_reset(mac_cfg0)) {
|
|
__le32 temp;
|
|
temp = 0;
|
|
netxen_gb_tx_reset_pb(temp);
|
|
netxen_gb_rx_reset_pb(temp);
|
|
netxen_gb_tx_reset_mac(temp);
|
|
netxen_gb_rx_reset_mac(temp);
|
|
|
|
if (netxen_nic_hw_write_wx(adapter,
|
|
NETXEN_NIU_GB_MAC_CONFIG_0(0),
|
|
&temp, 4))
|
|
return -EIO;
|
|
restore = 1;
|
|
}
|
|
|
|
command = 0; /* turn off any prior activity */
|
|
if (netxen_nic_hw_write_wx(adapter, NETXEN_NIU_GB_MII_MGMT_COMMAND(0),
|
|
&command, 4))
|
|
return -EIO;
|
|
|
|
address = 0;
|
|
netxen_gb_mii_mgmt_reg_addr(address, reg);
|
|
netxen_gb_mii_mgmt_phy_addr(address, phy);
|
|
if (netxen_nic_hw_write_wx(adapter, NETXEN_NIU_GB_MII_MGMT_ADDR(0),
|
|
&address, 4))
|
|
return -EIO;
|
|
|
|
if (netxen_nic_hw_write_wx(adapter, NETXEN_NIU_GB_MII_MGMT_CTRL(0),
|
|
&val, 4))
|
|
return -EIO;
|
|
|
|
status = 0;
|
|
do {
|
|
if (netxen_nic_hw_read_wx(adapter,
|
|
NETXEN_NIU_GB_MII_MGMT_INDICATE(0),
|
|
&status, 4))
|
|
return -EIO;
|
|
timeout++;
|
|
} while ((netxen_get_gb_mii_mgmt_busy(status))
|
|
&& (timeout++ < NETXEN_NIU_PHY_WAITMAX));
|
|
|
|
if (timeout < NETXEN_NIU_PHY_WAITMAX)
|
|
result = 0;
|
|
else
|
|
result = -EIO;
|
|
|
|
/* restore the state of port 0 MAC in case we tampered with it */
|
|
if (restore)
|
|
if (netxen_nic_hw_write_wx(adapter,
|
|
NETXEN_NIU_GB_MAC_CONFIG_0(0),
|
|
&mac_cfg0, 4))
|
|
return -EIO;
|
|
|
|
return result;
|
|
}
|
|
|
|
int netxen_niu_xgbe_enable_phy_interrupts(struct netxen_adapter *adapter,
|
|
int port)
|
|
{
|
|
netxen_crb_writelit_adapter(adapter, NETXEN_NIU_INT_MASK, 0x3f);
|
|
return 0;
|
|
}
|
|
|
|
int netxen_niu_gbe_enable_phy_interrupts(struct netxen_adapter *adapter,
|
|
int port)
|
|
{
|
|
int result = 0;
|
|
__le32 enable = 0;
|
|
netxen_set_phy_int_link_status_changed(enable);
|
|
netxen_set_phy_int_autoneg_completed(enable);
|
|
netxen_set_phy_int_speed_changed(enable);
|
|
|
|
if (0 !=
|
|
netxen_niu_gbe_phy_write(adapter, port,
|
|
NETXEN_NIU_GB_MII_MGMT_ADDR_INT_ENABLE,
|
|
enable))
|
|
result = -EIO;
|
|
|
|
return result;
|
|
}
|
|
|
|
int netxen_niu_xgbe_disable_phy_interrupts(struct netxen_adapter *adapter,
|
|
int port)
|
|
{
|
|
netxen_crb_writelit_adapter(adapter, NETXEN_NIU_INT_MASK, 0x7f);
|
|
return 0;
|
|
}
|
|
|
|
int netxen_niu_gbe_disable_phy_interrupts(struct netxen_adapter *adapter,
|
|
int port)
|
|
{
|
|
int result = 0;
|
|
if (0 !=
|
|
netxen_niu_gbe_phy_write(adapter, port,
|
|
NETXEN_NIU_GB_MII_MGMT_ADDR_INT_ENABLE, 0))
|
|
result = -EIO;
|
|
|
|
return result;
|
|
}
|
|
|
|
int netxen_niu_xgbe_clear_phy_interrupts(struct netxen_adapter *adapter,
|
|
int port)
|
|
{
|
|
netxen_crb_writelit_adapter(adapter, NETXEN_NIU_ACTIVE_INT, -1);
|
|
return 0;
|
|
}
|
|
|
|
int netxen_niu_gbe_clear_phy_interrupts(struct netxen_adapter *adapter,
|
|
int port)
|
|
{
|
|
int result = 0;
|
|
if (0 !=
|
|
netxen_niu_gbe_phy_write(adapter, port,
|
|
NETXEN_NIU_GB_MII_MGMT_ADDR_INT_STATUS,
|
|
-EIO))
|
|
result = -EIO;
|
|
|
|
return result;
|
|
}
|
|
|
|
/*
|
|
* netxen_niu_gbe_set_mii_mode- Set 10/100 Mbit Mode for GbE MAC
|
|
*
|
|
*/
|
|
void netxen_niu_gbe_set_mii_mode(struct netxen_adapter *adapter,
|
|
int port, long enable)
|
|
{
|
|
netxen_crb_writelit_adapter(adapter, NETXEN_NIU_MODE, 0x2);
|
|
netxen_crb_writelit_adapter(adapter, NETXEN_NIU_GB_MAC_CONFIG_0(port),
|
|
0x80000000);
|
|
netxen_crb_writelit_adapter(adapter, NETXEN_NIU_GB_MAC_CONFIG_0(port),
|
|
0x0000f0025);
|
|
netxen_crb_writelit_adapter(adapter, NETXEN_NIU_GB_MAC_CONFIG_1(port),
|
|
0xf1ff);
|
|
netxen_crb_writelit_adapter(adapter,
|
|
NETXEN_NIU_GB0_GMII_MODE + (port << 3), 0);
|
|
netxen_crb_writelit_adapter(adapter,
|
|
NETXEN_NIU_GB0_MII_MODE + (port << 3), 1);
|
|
netxen_crb_writelit_adapter(adapter,
|
|
(NETXEN_NIU_GB0_HALF_DUPLEX + port * 4), 0);
|
|
netxen_crb_writelit_adapter(adapter,
|
|
NETXEN_NIU_GB_MII_MGMT_CONFIG(port), 0x7);
|
|
|
|
if (enable) {
|
|
/*
|
|
* Do NOT enable flow control until a suitable solution for
|
|
* shutting down pause frames is found.
|
|
*/
|
|
netxen_crb_writelit_adapter(adapter,
|
|
NETXEN_NIU_GB_MAC_CONFIG_0(port),
|
|
0x5);
|
|
}
|
|
|
|
if (netxen_niu_gbe_enable_phy_interrupts(adapter, port))
|
|
printk(KERN_ERR PFX "ERROR enabling PHY interrupts\n");
|
|
if (netxen_niu_gbe_clear_phy_interrupts(adapter, port))
|
|
printk(KERN_ERR PFX "ERROR clearing PHY interrupts\n");
|
|
}
|
|
|
|
/*
|
|
* netxen_niu_gbe_set_gmii_mode- Set GbE Mode for GbE MAC
|
|
*/
|
|
void netxen_niu_gbe_set_gmii_mode(struct netxen_adapter *adapter,
|
|
int port, long enable)
|
|
{
|
|
netxen_crb_writelit_adapter(adapter, NETXEN_NIU_MODE, 0x2);
|
|
netxen_crb_writelit_adapter(adapter, NETXEN_NIU_GB_MAC_CONFIG_0(port),
|
|
0x80000000);
|
|
netxen_crb_writelit_adapter(adapter, NETXEN_NIU_GB_MAC_CONFIG_0(port),
|
|
0x0000f0025);
|
|
netxen_crb_writelit_adapter(adapter, NETXEN_NIU_GB_MAC_CONFIG_1(port),
|
|
0xf2ff);
|
|
netxen_crb_writelit_adapter(adapter,
|
|
NETXEN_NIU_GB0_MII_MODE + (port << 3), 0);
|
|
netxen_crb_writelit_adapter(adapter,
|
|
NETXEN_NIU_GB0_GMII_MODE + (port << 3), 1);
|
|
netxen_crb_writelit_adapter(adapter,
|
|
(NETXEN_NIU_GB0_HALF_DUPLEX + port * 4), 0);
|
|
netxen_crb_writelit_adapter(adapter,
|
|
NETXEN_NIU_GB_MII_MGMT_CONFIG(port), 0x7);
|
|
|
|
if (enable) {
|
|
/*
|
|
* Do NOT enable flow control until a suitable solution for
|
|
* shutting down pause frames is found.
|
|
*/
|
|
netxen_crb_writelit_adapter(adapter,
|
|
NETXEN_NIU_GB_MAC_CONFIG_0(port),
|
|
0x5);
|
|
}
|
|
|
|
if (netxen_niu_gbe_enable_phy_interrupts(adapter, port))
|
|
printk(KERN_ERR PFX "ERROR enabling PHY interrupts\n");
|
|
if (netxen_niu_gbe_clear_phy_interrupts(adapter, port))
|
|
printk(KERN_ERR PFX "ERROR clearing PHY interrupts\n");
|
|
}
|
|
|
|
int netxen_niu_gbe_init_port(struct netxen_adapter *adapter, int port)
|
|
{
|
|
int result = 0;
|
|
__le32 status;
|
|
if (adapter->ops->disable_phy_interrupts)
|
|
adapter->ops->disable_phy_interrupts(adapter, port);
|
|
mdelay(2);
|
|
|
|
if (0 ==
|
|
netxen_niu_gbe_phy_read(adapter, port,
|
|
NETXEN_NIU_GB_MII_MGMT_ADDR_PHY_STATUS,
|
|
(__le32 *) & status)) {
|
|
if (netxen_get_phy_link(status)) {
|
|
if (netxen_get_phy_speed(status) == 2) {
|
|
netxen_niu_gbe_set_gmii_mode(adapter, port, 1);
|
|
} else if ((netxen_get_phy_speed(status) == 1)
|
|
|| (netxen_get_phy_speed(status) == 0)) {
|
|
netxen_niu_gbe_set_mii_mode(adapter, port, 1);
|
|
} else {
|
|
result = -1;
|
|
}
|
|
|
|
} else {
|
|
/*
|
|
* We don't have link. Cable must be unconnected.
|
|
* Enable phy interrupts so we take action when
|
|
* plugged in.
|
|
*/
|
|
|
|
netxen_crb_writelit_adapter(adapter,
|
|
NETXEN_NIU_GB_MAC_CONFIG_0
|
|
(port),
|
|
NETXEN_GB_MAC_SOFT_RESET);
|
|
netxen_crb_writelit_adapter(adapter,
|
|
NETXEN_NIU_GB_MAC_CONFIG_0
|
|
(port),
|
|
NETXEN_GB_MAC_RESET_PROT_BLK
|
|
| NETXEN_GB_MAC_ENABLE_TX_RX
|
|
|
|
|
NETXEN_GB_MAC_PAUSED_FRMS);
|
|
if (netxen_niu_gbe_clear_phy_interrupts(adapter, port))
|
|
printk(KERN_ERR PFX
|
|
"ERROR clearing PHY interrupts\n");
|
|
if (netxen_niu_gbe_enable_phy_interrupts(adapter, port))
|
|
printk(KERN_ERR PFX
|
|
"ERROR enabling PHY interrupts\n");
|
|
if (netxen_niu_gbe_clear_phy_interrupts(adapter, port))
|
|
printk(KERN_ERR PFX
|
|
"ERROR clearing PHY interrupts\n");
|
|
result = -1;
|
|
}
|
|
} else {
|
|
result = -EIO;
|
|
}
|
|
return result;
|
|
}
|
|
|
|
int netxen_niu_xg_init_port(struct netxen_adapter *adapter, int port)
|
|
{
|
|
long reg = 0, ret = 0;
|
|
|
|
if (adapter->ahw.boardcfg.board_type == NETXEN_BRDTYPE_P2_SB31_10G_IMEZ) {
|
|
netxen_crb_writelit_adapter(adapter,
|
|
NETXEN_NIU_XG1_CONFIG_0, 0x5);
|
|
/* XXX hack for Mez cards: both ports in promisc mode */
|
|
netxen_nic_hw_read_wx(adapter,
|
|
NETXEN_NIU_XGE_CONFIG_1, ®, 4);
|
|
reg = (reg | 0x2000UL);
|
|
netxen_crb_writelit_adapter(adapter,
|
|
NETXEN_NIU_XGE_CONFIG_1, reg);
|
|
reg = 0;
|
|
netxen_nic_hw_read_wx(adapter,
|
|
NETXEN_NIU_XG1_CONFIG_1, ®, 4);
|
|
reg = (reg | 0x2000UL);
|
|
netxen_crb_writelit_adapter(adapter,
|
|
NETXEN_NIU_XG1_CONFIG_1, reg);
|
|
}
|
|
|
|
return ret;
|
|
}
|
|
|
|
/*
|
|
* netxen_niu_gbe_handle_phy_interrupt - Handles GbE PHY interrupts
|
|
* @param enable 0 means don't enable the port
|
|
* 1 means enable (or re-enable) the port
|
|
*/
|
|
int netxen_niu_gbe_handle_phy_interrupt(struct netxen_adapter *adapter,
|
|
int port, long enable)
|
|
{
|
|
int result = 0;
|
|
__le32 int_src;
|
|
|
|
printk(KERN_INFO PFX "NETXEN: Handling PHY interrupt on port %d"
|
|
" (device enable = %d)\n", (int)port, (int)enable);
|
|
|
|
/*
|
|
* The read of the PHY INT status will clear the pending
|
|
* interrupt status
|
|
*/
|
|
if (netxen_niu_gbe_phy_read(adapter, port,
|
|
NETXEN_NIU_GB_MII_MGMT_ADDR_INT_STATUS,
|
|
&int_src) != 0)
|
|
result = -EINVAL;
|
|
else {
|
|
printk(KERN_INFO PFX "PHY Interrupt source = 0x%x \n", int_src);
|
|
if (netxen_get_phy_int_jabber(int_src))
|
|
printk(KERN_INFO PFX "jabber Interrupt ");
|
|
if (netxen_get_phy_int_polarity_changed(int_src))
|
|
printk(KERN_INFO PFX "polarity changed ");
|
|
if (netxen_get_phy_int_energy_detect(int_src))
|
|
printk(KERN_INFO PFX "energy detect \n");
|
|
if (netxen_get_phy_int_downshift(int_src))
|
|
printk(KERN_INFO PFX "downshift \n");
|
|
if (netxen_get_phy_int_mdi_xover_changed(int_src))
|
|
printk(KERN_INFO PFX "mdi_xover_changed ");
|
|
if (netxen_get_phy_int_fifo_over_underflow(int_src))
|
|
printk(KERN_INFO PFX "fifo_over_underflow ");
|
|
if (netxen_get_phy_int_false_carrier(int_src))
|
|
printk(KERN_INFO PFX "false_carrier ");
|
|
if (netxen_get_phy_int_symbol_error(int_src))
|
|
printk(KERN_INFO PFX "symbol_error ");
|
|
if (netxen_get_phy_int_autoneg_completed(int_src))
|
|
printk(KERN_INFO PFX "autoneg_completed ");
|
|
if (netxen_get_phy_int_page_received(int_src))
|
|
printk(KERN_INFO PFX "page_received ");
|
|
if (netxen_get_phy_int_duplex_changed(int_src))
|
|
printk(KERN_INFO PFX "duplex_changed ");
|
|
if (netxen_get_phy_int_autoneg_error(int_src))
|
|
printk(KERN_INFO PFX "autoneg_error ");
|
|
if ((netxen_get_phy_int_speed_changed(int_src))
|
|
|| (netxen_get_phy_int_link_status_changed(int_src))) {
|
|
__le32 status;
|
|
|
|
printk(KERN_INFO PFX
|
|
"speed_changed or link status changed");
|
|
if (netxen_niu_gbe_phy_read
|
|
(adapter, port,
|
|
NETXEN_NIU_GB_MII_MGMT_ADDR_PHY_STATUS,
|
|
&status) == 0) {
|
|
if (netxen_get_phy_speed(status) == 2) {
|
|
printk
|
|
(KERN_INFO PFX "Link speed changed"
|
|
" to 1000 Mbps\n");
|
|
netxen_niu_gbe_set_gmii_mode(adapter,
|
|
port,
|
|
enable);
|
|
} else if (netxen_get_phy_speed(status) == 1) {
|
|
printk
|
|
(KERN_INFO PFX "Link speed changed"
|
|
" to 100 Mbps\n");
|
|
netxen_niu_gbe_set_mii_mode(adapter,
|
|
port,
|
|
enable);
|
|
} else if (netxen_get_phy_speed(status) == 0) {
|
|
printk
|
|
(KERN_INFO PFX "Link speed changed"
|
|
" to 10 Mbps\n");
|
|
netxen_niu_gbe_set_mii_mode(adapter,
|
|
port,
|
|
enable);
|
|
} else {
|
|
printk(KERN_ERR PFX "ERROR reading"
|
|
"PHY status. Illegal speed.\n");
|
|
result = -1;
|
|
}
|
|
} else {
|
|
printk(KERN_ERR PFX
|
|
"ERROR reading PHY status.\n");
|
|
result = -1;
|
|
}
|
|
|
|
}
|
|
printk(KERN_INFO "\n");
|
|
}
|
|
return result;
|
|
}
|
|
|
|
/*
|
|
* Return the current station MAC address.
|
|
* Note that the passed-in value must already be in network byte order.
|
|
*/
|
|
int netxen_niu_macaddr_get(struct netxen_adapter *adapter,
|
|
int phy, netxen_ethernet_macaddr_t * addr)
|
|
{
|
|
u64 result = 0;
|
|
__le32 stationhigh;
|
|
__le32 stationlow;
|
|
|
|
if (addr == NULL)
|
|
return -EINVAL;
|
|
if ((phy < 0) || (phy > 3))
|
|
return -EINVAL;
|
|
|
|
if (netxen_nic_hw_read_wx(adapter, NETXEN_NIU_GB_STATION_ADDR_0(phy),
|
|
&stationhigh, 4))
|
|
return -EIO;
|
|
if (netxen_nic_hw_read_wx(adapter, NETXEN_NIU_GB_STATION_ADDR_1(phy),
|
|
&stationlow, 4))
|
|
return -EIO;
|
|
|
|
result = (u64) netxen_gb_get_stationaddress_low(stationlow);
|
|
result |= (u64) stationhigh << 16;
|
|
memcpy(*addr, &result, sizeof(netxen_ethernet_macaddr_t));
|
|
|
|
return 0;
|
|
}
|
|
|
|
/*
|
|
* Set the station MAC address.
|
|
* Note that the passed-in value must already be in network byte order.
|
|
*/
|
|
int netxen_niu_macaddr_set(struct netxen_port *port,
|
|
netxen_ethernet_macaddr_t addr)
|
|
{
|
|
__le32 temp = 0;
|
|
struct netxen_adapter *adapter = port->adapter;
|
|
int phy = port->portnum;
|
|
unsigned char mac_addr[MAX_ADDR_LEN];
|
|
int i;
|
|
|
|
for (i = 0; i < 10; i++) {
|
|
memcpy(&temp, addr, 2);
|
|
temp <<= 16;
|
|
if (netxen_nic_hw_write_wx
|
|
(adapter, NETXEN_NIU_GB_STATION_ADDR_1(phy), &temp, 4))
|
|
return -EIO;
|
|
|
|
temp = 0;
|
|
|
|
memcpy(&temp, ((u8 *) addr) + 2, sizeof(__le32));
|
|
if (netxen_nic_hw_write_wx
|
|
(adapter, NETXEN_NIU_GB_STATION_ADDR_0(phy), &temp, 4))
|
|
return -2;
|
|
|
|
netxen_niu_macaddr_get(adapter, phy,
|
|
(netxen_ethernet_macaddr_t *) mac_addr);
|
|
if (memcmp(mac_addr, addr, MAX_ADDR_LEN == 0))
|
|
break;
|
|
}
|
|
|
|
if (i == 10) {
|
|
printk(KERN_ERR "%s: cannot set Mac addr for %s\n",
|
|
netxen_nic_driver_name, port->netdev->name);
|
|
printk(KERN_ERR "MAC address set: "
|
|
"%02x:%02x:%02x:%02x:%02x:%02x.\n",
|
|
addr[0], addr[1], addr[2], addr[3], addr[4], addr[5]);
|
|
|
|
printk(KERN_ERR "MAC address get: "
|
|
"%02x:%02x:%02x:%02x:%02x:%02x.\n",
|
|
mac_addr[0],
|
|
mac_addr[1],
|
|
mac_addr[2], mac_addr[3], mac_addr[4], mac_addr[5]);
|
|
}
|
|
return 0;
|
|
}
|
|
|
|
/* Enable a GbE interface */
|
|
int netxen_niu_enable_gbe_port(struct netxen_adapter *adapter,
|
|
int port, netxen_niu_gbe_ifmode_t mode)
|
|
{
|
|
__le32 mac_cfg0;
|
|
__le32 mac_cfg1;
|
|
__le32 mii_cfg;
|
|
|
|
if ((port < 0) || (port > NETXEN_NIU_MAX_GBE_PORTS))
|
|
return -EINVAL;
|
|
|
|
mac_cfg0 = 0;
|
|
netxen_gb_soft_reset(mac_cfg0);
|
|
if (netxen_nic_hw_write_wx(adapter, NETXEN_NIU_GB_MAC_CONFIG_0(port),
|
|
&mac_cfg0, 4))
|
|
return -EIO;
|
|
mac_cfg0 = 0;
|
|
netxen_gb_enable_tx(mac_cfg0);
|
|
netxen_gb_enable_rx(mac_cfg0);
|
|
netxen_gb_unset_rx_flowctl(mac_cfg0);
|
|
netxen_gb_tx_reset_pb(mac_cfg0);
|
|
netxen_gb_rx_reset_pb(mac_cfg0);
|
|
netxen_gb_tx_reset_mac(mac_cfg0);
|
|
netxen_gb_rx_reset_mac(mac_cfg0);
|
|
|
|
if (netxen_nic_hw_write_wx(adapter, NETXEN_NIU_GB_MAC_CONFIG_0(port),
|
|
&mac_cfg0, 4))
|
|
return -EIO;
|
|
mac_cfg1 = 0;
|
|
netxen_gb_set_preamblelen(mac_cfg1, 0xf);
|
|
netxen_gb_set_duplex(mac_cfg1);
|
|
netxen_gb_set_crc_enable(mac_cfg1);
|
|
netxen_gb_set_padshort(mac_cfg1);
|
|
netxen_gb_set_checklength(mac_cfg1);
|
|
netxen_gb_set_hugeframes(mac_cfg1);
|
|
|
|
if (mode == NETXEN_NIU_10_100_MB) {
|
|
netxen_gb_set_intfmode(mac_cfg1, 1);
|
|
if (netxen_nic_hw_write_wx(adapter,
|
|
NETXEN_NIU_GB_MAC_CONFIG_1(port),
|
|
&mac_cfg1, 4))
|
|
return -EIO;
|
|
|
|
/* set mii mode */
|
|
netxen_crb_writelit_adapter(adapter, NETXEN_NIU_GB0_GMII_MODE +
|
|
(port << 3), 0);
|
|
netxen_crb_writelit_adapter(adapter, NETXEN_NIU_GB0_MII_MODE +
|
|
(port << 3), 1);
|
|
|
|
} else if (mode == NETXEN_NIU_1000_MB) {
|
|
netxen_gb_set_intfmode(mac_cfg1, 2);
|
|
if (netxen_nic_hw_write_wx(adapter,
|
|
NETXEN_NIU_GB_MAC_CONFIG_1(port),
|
|
&mac_cfg1, 4))
|
|
return -EIO;
|
|
/* set gmii mode */
|
|
netxen_crb_writelit_adapter(adapter, NETXEN_NIU_GB0_MII_MODE +
|
|
(port << 3), 0);
|
|
netxen_crb_writelit_adapter(adapter, NETXEN_NIU_GB0_GMII_MODE +
|
|
(port << 3), 1);
|
|
}
|
|
mii_cfg = 0;
|
|
netxen_gb_set_mii_mgmt_clockselect(mii_cfg, 7);
|
|
if (netxen_nic_hw_write_wx(adapter, NETXEN_NIU_GB_MII_MGMT_CONFIG(port),
|
|
&mii_cfg, 4))
|
|
return -EIO;
|
|
mac_cfg0 = 0;
|
|
netxen_gb_enable_tx(mac_cfg0);
|
|
netxen_gb_enable_rx(mac_cfg0);
|
|
netxen_gb_unset_rx_flowctl(mac_cfg0);
|
|
netxen_gb_unset_tx_flowctl(mac_cfg0);
|
|
|
|
if (netxen_nic_hw_write_wx(adapter, NETXEN_NIU_GB_MAC_CONFIG_0(port),
|
|
&mac_cfg0, 4))
|
|
return -EIO;
|
|
return 0;
|
|
}
|
|
|
|
/* Disable a GbE interface */
|
|
int netxen_niu_disable_gbe_port(struct netxen_adapter *adapter, int port)
|
|
{
|
|
__le32 mac_cfg0;
|
|
|
|
if ((port < 0) || (port > NETXEN_NIU_MAX_GBE_PORTS))
|
|
return -EINVAL;
|
|
|
|
mac_cfg0 = 0;
|
|
netxen_gb_soft_reset(mac_cfg0);
|
|
if (netxen_nic_hw_write_wx(adapter, NETXEN_NIU_GB_MAC_CONFIG_0(port),
|
|
&mac_cfg0, 4))
|
|
return -EIO;
|
|
return 0;
|
|
}
|
|
|
|
/* Disable an XG interface */
|
|
int netxen_niu_disable_xg_port(struct netxen_adapter *adapter, int port)
|
|
{
|
|
__le32 mac_cfg;
|
|
|
|
if (port != 0)
|
|
return -EINVAL;
|
|
|
|
mac_cfg = 0;
|
|
netxen_xg_soft_reset(mac_cfg);
|
|
if (netxen_nic_hw_write_wx(adapter, NETXEN_NIU_XGE_CONFIG_0,
|
|
&mac_cfg, 4))
|
|
return -EIO;
|
|
return 0;
|
|
}
|
|
|
|
/* Set promiscuous mode for a GbE interface */
|
|
int netxen_niu_set_promiscuous_mode(struct netxen_adapter *adapter, int port,
|
|
netxen_niu_prom_mode_t mode)
|
|
{
|
|
__le32 reg;
|
|
|
|
if ((port < 0) || (port > NETXEN_NIU_MAX_GBE_PORTS))
|
|
return -EINVAL;
|
|
|
|
/* save previous contents */
|
|
if (netxen_nic_hw_read_wx(adapter, NETXEN_NIU_GB_DROP_WRONGADDR,
|
|
®, 4))
|
|
return -EIO;
|
|
if (mode == NETXEN_NIU_PROMISC_MODE) {
|
|
switch (port) {
|
|
case 0:
|
|
netxen_clear_gb_drop_gb0(reg);
|
|
break;
|
|
case 1:
|
|
netxen_clear_gb_drop_gb1(reg);
|
|
break;
|
|
case 2:
|
|
netxen_clear_gb_drop_gb2(reg);
|
|
break;
|
|
case 3:
|
|
netxen_clear_gb_drop_gb3(reg);
|
|
break;
|
|
default:
|
|
return -EIO;
|
|
}
|
|
} else {
|
|
switch (port) {
|
|
case 0:
|
|
netxen_set_gb_drop_gb0(reg);
|
|
break;
|
|
case 1:
|
|
netxen_set_gb_drop_gb1(reg);
|
|
break;
|
|
case 2:
|
|
netxen_set_gb_drop_gb2(reg);
|
|
break;
|
|
case 3:
|
|
netxen_set_gb_drop_gb3(reg);
|
|
break;
|
|
default:
|
|
return -EIO;
|
|
}
|
|
}
|
|
if (netxen_nic_hw_write_wx(adapter, NETXEN_NIU_GB_DROP_WRONGADDR,
|
|
®, 4))
|
|
return -EIO;
|
|
return 0;
|
|
}
|
|
|
|
/*
|
|
* Set the MAC address for an XG port
|
|
* Note that the passed-in value must already be in network byte order.
|
|
*/
|
|
int netxen_niu_xg_macaddr_set(struct netxen_port *port,
|
|
netxen_ethernet_macaddr_t addr)
|
|
{
|
|
__le32 temp = 0;
|
|
struct netxen_adapter *adapter = port->adapter;
|
|
|
|
memcpy(&temp, addr, 2);
|
|
temp = cpu_to_le32(temp);
|
|
temp <<= 16;
|
|
if (netxen_nic_hw_write_wx(adapter, NETXEN_NIU_XGE_STATION_ADDR_0_1,
|
|
&temp, 4))
|
|
return -EIO;
|
|
|
|
temp = 0;
|
|
|
|
memcpy(&temp, ((u8 *) addr) + 2, sizeof(__le32));
|
|
temp = cpu_to_le32(temp);
|
|
if (netxen_nic_hw_write_wx(adapter, NETXEN_NIU_XGE_STATION_ADDR_0_HI,
|
|
&temp, 4))
|
|
return -EIO;
|
|
|
|
return 0;
|
|
}
|
|
|
|
/*
|
|
* Return the current station MAC address.
|
|
* Note that the passed-in value must already be in network byte order.
|
|
*/
|
|
int netxen_niu_xg_macaddr_get(struct netxen_adapter *adapter, int phy,
|
|
netxen_ethernet_macaddr_t * addr)
|
|
{
|
|
__le32 stationhigh;
|
|
__le32 stationlow;
|
|
u64 result;
|
|
|
|
if (addr == NULL)
|
|
return -EINVAL;
|
|
if (phy != 0)
|
|
return -EINVAL;
|
|
|
|
if (netxen_nic_hw_read_wx(adapter, NETXEN_NIU_XGE_STATION_ADDR_0_HI,
|
|
&stationhigh, 4))
|
|
return -EIO;
|
|
if (netxen_nic_hw_read_wx(adapter, NETXEN_NIU_XGE_STATION_ADDR_0_1,
|
|
&stationlow, 4))
|
|
return -EIO;
|
|
|
|
result = ((u64) stationlow) >> 16;
|
|
result |= (u64) stationhigh << 16;
|
|
memcpy(*addr, &result, sizeof(netxen_ethernet_macaddr_t));
|
|
|
|
return 0;
|
|
}
|
|
|
|
int netxen_niu_xg_set_promiscuous_mode(struct netxen_adapter *adapter,
|
|
int port, netxen_niu_prom_mode_t mode)
|
|
{
|
|
__le32 reg;
|
|
|
|
if ((port < 0) || (port > NETXEN_NIU_MAX_GBE_PORTS))
|
|
return -EINVAL;
|
|
|
|
if (netxen_nic_hw_read_wx(adapter, NETXEN_NIU_XGE_CONFIG_1, ®, 4))
|
|
return -EIO;
|
|
if (mode == NETXEN_NIU_PROMISC_MODE)
|
|
reg = (reg | 0x2000UL);
|
|
else
|
|
reg = (reg & ~0x2000UL);
|
|
|
|
netxen_crb_writelit_adapter(adapter, NETXEN_NIU_XGE_CONFIG_1, reg);
|
|
|
|
return 0;
|
|
}
|