When doing successive oversampling settings, it may fail to update filter
parameters silently:
- First time oversampling is being set, it will be successful, as fl->res
is 0 initially.
- Next attempts with various oversamp value may return 0 (success), but
keep previous filter parameters, due to 'res' never reaches above or
equal current 'fl->res'.
This is particularly true when setting sampling frequency (that relies on
oversamp). Typical failure without error:
- run 1st test @16kHz samp freq will succeed
- run new test @8kHz will succeed as well
- run new test @16kHz (again): sample rate will remain 8kHz without error
Fixes: e2e6771c64 ("IIO: ADC: add STM32 DFSDM sigma delta ADC support")
Signed-off-by: Fabrice Gasnier <fabrice.gasnier@st.com>
Acked-by: Arnaud Pouliquen <arnaud.pouliquen@st.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>