The TEAC UD-H01 firmware sends wrong feedback frequency values, thus causing the PC to send the samples at a wrong rate, which results in clicks and crackles in the output. Add a workaround to detect and fix the corruption. Signed-off-by: Clemens Ladisch <clemens@ladisch.de> [mick37@gmx.de: use sender->udh01_fb_quirk rather than ep->udh01_fb_quirk in snd_usb_handle_sync_urb()] Reported-and-tested-by: Mick <mick37@gmx.de> Reported-and-tested-by: Andrea Messa <andr.messa@tiscali.it> Cc: <stable@vger.kernel.org> Signed-off-by: Takashi Iwai <tiwai@suse.de> |
||
---|---|---|
.. | ||