linux_dsm_epyc7002/arch/arm/boot/dts/omap4-cpu-thermal.dtsi
Eduardo Valentin 0bbf6c54d1 arm: dts: add omap4 CPU thermal data
This patch changes a dtsi file to contain the thermal data
for MPU domain on OMAP4 and later SoCs. This data will
enable the passive cooling with CPUfreq cooling device
at 100C and the system will do a thermal shutdown at 125C.

This thermal data can be reused across TI SoC devices.

Cc: "Benoît Cousson" <bcousson@baylibre.com>
Cc: Tony Lindgren <tony@atomide.com>
Cc: Rob Herring <rob.herring@calxeda.com>
Cc: Pawel Moll <pawel.moll@arm.com>
Cc: Mark Rutland <mark.rutland@arm.com>
Cc: Stephen Warren <swarren@wwwdotorg.org>
Cc: Ian Campbell <ian.campbell@citrix.com>
Cc: Russell King <linux@arm.linux.org.uk>
Cc: linux-omap@vger.kernel.org
Cc: devicetree@vger.kernel.org
Cc: linux-arm-kernel@lists.infradead.org
Cc: linux-kernel@vger.kernel.org
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
2013-12-04 09:34:25 -04:00

42 lines
1.2 KiB
Plaintext

/*
* Device Tree Source for OMAP4/5 SoC CPU thermal
*
* Copyright (C) 2013 Texas Instruments Incorporated - http://www.ti.com/
* Contact: Eduardo Valentin <eduardo.valentin@ti.com>
*
* This file is licensed under the terms of the GNU General Public License
* version 2. This program is licensed "as is" without any warranty of any
* kind, whether express or implied.
*/
#include <dt-bindings/thermal/thermal.h>
cpu_thermal: cpu_thermal {
polling-delay-passive = <250>; /* milliseconds */
polling-delay = <1000>; /* milliseconds */
/* sensor ID */
thermal-sensors = <&bandgap 0>;
trips {
cpu_alert0: cpu_alert {
temperature = <100000>; /* millicelsius */
hysteresis = <2000>; /* millicelsius */
type = "passive";
};
cpu_crit: cpu_crit {
temperature = <125000>; /* millicelsius */
hysteresis = <2000>; /* millicelsius */
type = "critical";
};
};
cooling-maps {
map0 {
trip = <&cpu_alert0>;
cooling-device =
<&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
};
};
};