When sample rate of TX is different with sample rate of RX in
async mode, the MFreq selection will be wrong.
For example, sysclk = 24.576MHz, TX rate = 96000Hz, RX rate = 48000Hz.
Then ratio of TX = 256, ratio of RX = 512, For MFreq is shared by TX
and RX instance, the correct value of MFreq is 2 for both TX and RX.
But original method will cause MFreq = 0 for TX, MFreq = 2 for RX.
If TX is started after RX, RX will be impacted, RX work abnormal with
MFreq = 0.
This patch is to select proper MFreq value according to TX rate and
RX rate.
Fixes: 0c516b4ff8 ("ASoC: cs42xx8: Add codec driver support for CS42448/CS42888")
Signed-off-by: Shengjiu Wang <shengjiu.wang@nxp.com>
Link: https://lore.kernel.org/r/20190716094547.46787-1-shengjiu.wang@nxp.com
Signed-off-by: Mark Brown <broonie@kernel.org>