mirror of
https://github.com/AuxXxilium/linux_dsm_epyc7002.git
synced 2024-11-30 12:16:45 +07:00
12920b02c0
R-Mobile APE6 (r8a73a4) is handled fine by the same driver and bindings. Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be> Signed-off-by: Simon Horman <horms+renesas@verge.net.au>
101 lines
2.8 KiB
Plaintext
101 lines
2.8 KiB
Plaintext
DT bindings for the Renesas R-Mobile System Controller
|
|
|
|
== System Controller Node ==
|
|
|
|
The R-Mobile System Controller provides the following functions:
|
|
- Boot mode management,
|
|
- Reset generation,
|
|
- Power management.
|
|
|
|
Required properties:
|
|
- compatible: Should be "renesas,sysc-<soctype>", "renesas,sysc-rmobile" as
|
|
fallback.
|
|
Examples with soctypes are:
|
|
- "renesas,sysc-r8a73a4" (R-Mobile APE6)
|
|
- "renesas,sysc-r8a7740" (R-Mobile A1)
|
|
- "renesas,sysc-sh73a0" (SH-Mobile AG5)
|
|
- reg: Two address start and address range blocks for the device:
|
|
- The first block refers to the normally accessible registers,
|
|
- the second block refers to the registers protected by the HPB
|
|
semaphore.
|
|
|
|
Optional nodes:
|
|
- pm-domains: This node contains a hierarchy of PM domain nodes, which should
|
|
match the Power Area Hierarchy in the Power Domain Specifications section of
|
|
the device's datasheet.
|
|
|
|
|
|
== PM Domain Nodes ==
|
|
|
|
Each of the PM domain nodes represents a PM domain, as documented by the
|
|
generic PM domain bindings in
|
|
Documentation/devicetree/bindings/power/power_domain.txt.
|
|
|
|
The nodes should be named by the real power area names, and thus their names
|
|
should be unique.
|
|
|
|
Required properties:
|
|
- #power-domain-cells: Must be 0.
|
|
|
|
Optional properties:
|
|
- reg: If the PM domain is not always-on, this property must contain the bit
|
|
index number for the corresponding power area in the various Power
|
|
Control and Status Registers. The parent's node must contain the
|
|
following two properties:
|
|
- #address-cells: Must be 1,
|
|
- #size-cells: Must be 0.
|
|
If the PM domain is always-on, this property must be omitted.
|
|
|
|
|
|
Example:
|
|
|
|
This shows a subset of the r8a7740 PM domain hierarchy, containing the
|
|
C5 "always-on" domain, 2 of its subdomains (A4S and A4SU), and the A3SP domain,
|
|
which is a subdomain of A4S.
|
|
|
|
sysc: system-controller@e6180000 {
|
|
compatible = "renesas,sysc-r8a7740", "renesas,sysc-rmobile";
|
|
reg = <0xe6180000 0x8000>, <0xe6188000 0x8000>;
|
|
|
|
pm-domains {
|
|
pd_c5: c5 {
|
|
#address-cells = <1>;
|
|
#size-cells = <0>;
|
|
#power-domain-cells = <0>;
|
|
|
|
pd_a4s: a4s@10 {
|
|
reg = <10>;
|
|
#address-cells = <1>;
|
|
#size-cells = <0>;
|
|
#power-domain-cells = <0>;
|
|
|
|
pd_a3sp: a3sp@11 {
|
|
reg = <11>;
|
|
#power-domain-cells = <0>;
|
|
};
|
|
};
|
|
|
|
pd_a4su: a4su@20 {
|
|
reg = <20>;
|
|
#power-domain-cells = <0>;
|
|
};
|
|
};
|
|
};
|
|
};
|
|
|
|
|
|
== PM Domain Consumers ==
|
|
|
|
Hardware blocks belonging to a PM domain should contain a "power-domains"
|
|
property that is a phandle pointing to the corresponding PM domain node.
|
|
|
|
Example:
|
|
|
|
tpu: pwm@e6600000 {
|
|
compatible = "renesas,tpu-r8a7740", "renesas,tpu";
|
|
reg = <0xe6600000 0x100>;
|
|
clocks = <&mstp3_clks R8A7740_CLK_TPU0>;
|
|
power-domains = <&pd_a3sp>;
|
|
#pwm-cells = <3>;
|
|
};
|