* Marvell Armada 370/375/380/XP thermal management
|
|
|
|
Required properties:
|
|
|
|
- compatible: Should be set to one of the following:
|
|
* marvell,armada370-thermal
|
|
* marvell,armada375-thermal
|
|
* marvell,armada380-thermal
|
|
* marvell,armadaxp-thermal
|
|
* marvell,armada-ap806-thermal
|
|
* marvell,armada-cp110-thermal
|
|
|
|
Note: these bindings are deprecated for AP806/CP110 and should instead
|
|
follow the rules described in:
|
|
Documentation/devicetree/bindings/arm/marvell/ap806-system-controller.txt
|
|
Documentation/devicetree/bindings/arm/marvell/cp110-system-controller.txt
|
|
|
|
- reg: Device's register space.
|
|
Two entries are expected, see the examples below. The first one points
|
|
to the status register (4B). The second one points to the control
|
|
registers (8B).
|
|
Note: The compatibles marvell,armada370-thermal,
|
|
marvell,armada380-thermal, and marvell,armadaxp-thermal must point to
|
|
"control MSB/control 1", with size of 4 (deprecated binding), or point
|
|
to "control LSB/control 0" with size of 8 (current binding). All other
|
|
compatibles must point to "control LSB/control 0" with size of 8.
|
|
|
|
Examples:
|
|
|
|
/* Legacy bindings */
|
|
thermal@d0018300 {
|
|
compatible = "marvell,armada370-thermal";
|
|
reg = <0xd0018300 0x4
|
|
0xd0018304 0x4>;
|
|
};
|
|
|
|
ap_thermal: thermal@6f8084 {
|
|
compatible = "marvell,armada-ap806-thermal";
|
|
reg = <0x6f808C 0x4>,
|
|
<0x6f8084 0x8>;
|
|
};
|