linux_dsm_epyc7002/Documentation/devicetree/bindings/clock/renesas,r9a06g032-sysctrl.txt
Gareth Williams af9422a857 dt-bindings: clock: renesas: r9a06g032-sysctrl: Document power Domains
The driver is gaining power domain support, so add the new property
to the DT binding and update the examples.

Signed-off-by: Gareth Williams <gareth.williams.jx@renesas.com>
Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be>
2019-06-04 11:50:58 +02:00

47 lines
1.2 KiB
Plaintext

* Renesas R9A06G032 SYSCTRL
Required Properties:
- compatible: Must be:
- "renesas,r9a06g032-sysctrl"
- reg: Base address and length of the SYSCTRL IO block.
- #clock-cells: Must be 1
- clocks: References to the parent clocks:
- external 40mhz crystal.
- external (optional) 32.768khz
- external (optional) jtag input
- external (optional) RGMII_REFCLK
- clock-names: Must be:
clock-names = "mclk", "rtc", "jtag", "rgmii_ref_ext";
- #power-domain-cells: Must be 0
Examples
--------
- SYSCTRL node:
sysctrl: system-controller@4000c000 {
compatible = "renesas,r9a06g032-sysctrl";
reg = <0x4000c000 0x1000>;
#clock-cells = <1>;
clocks = <&ext_mclk>, <&ext_rtc_clk>,
<&ext_jtag_clk>, <&ext_rgmii_ref>;
clock-names = "mclk", "rtc", "jtag", "rgmii_ref_ext";
#power-domain-cells = <0>;
};
- Other nodes can use the clocks provided by SYSCTRL as in:
#include <dt-bindings/clock/r9a06g032-sysctrl.h>
uart0: serial@40060000 {
compatible = "snps,dw-apb-uart";
reg = <0x40060000 0x400>;
interrupts = <GIC_SPI 6 IRQ_TYPE_LEVEL_HIGH>;
reg-shift = <2>;
reg-io-width = <4>;
clocks = <&sysctrl R9A06G032_CLK_UART0>, <&sysctrl R9A06G032_HCLK_UART0>;
clock-names = "baudclk", "apb_pclk";
power-domains = <&sysctrl>;
};