What: /sys/bus/counter/devices/counterX/countY/count
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Count data of Count Y represented as a string.
What: /sys/bus/counter/devices/counterX/countY/ceiling
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Count value ceiling for Count Y. This is the upper limit for the
respective counter.
What: /sys/bus/counter/devices/counterX/countY/floor
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Count value floor for Count Y. This is the lower limit for the
respective counter.
What: /sys/bus/counter/devices/counterX/countY/count_mode
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Count mode for channel Y. The ceiling and floor values for
Count Y are used by the count mode where required. The following
count modes are available:
normal:
Counting is continuous in either direction.
range limit:
An upper or lower limit is set, mimicking limit switches
in the mechanical counterpart. The upper limit is set to
the Count Y ceiling value, while the lower limit is set
to the Count Y floor value. The counter freezes at
count = ceiling when counting up, and at count = floor
when counting down. At either of these limits, the
counting is resumed only when the count direction is
reversed.
non-recycle:
The counter is disabled whenever a counter overflow or
underflow takes place. The counter is re-enabled when a
new count value is loaded to the counter via a preset
operation or direct write.
modulo-n:
A count value boundary is set between the Count Y floor
value and the Count Y ceiling value. The counter is
reset to the Count Y floor value at count = ceiling when
counting up, while the counter is set to the Count Y
ceiling value at count = floor when counting down; the
counter does not freeze at the boundary points, but
counts continuously throughout.
What: /sys/bus/counter/devices/counterX/countY/count_mode_available
What: /sys/bus/counter/devices/counterX/countY/error_noise_available
What: /sys/bus/counter/devices/counterX/countY/function_available
What: /sys/bus/counter/devices/counterX/countY/signalZ_action_available
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Discrete set of available values for the respective Count Y
configuration are listed in this file. Values are delimited by
newline characters.
What: /sys/bus/counter/devices/counterX/countY/direction
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Read-only attribute that indicates the count direction of Count
Y. Two count directions are available: forward and backward.
Some counter devices are able to determine the direction of
their counting. For example, quadrature encoding counters can
determine the direction of movement by evaluating the leading
phase of the respective A and B quadrature encoding signals.
This attribute exposes such count directions.
What: /sys/bus/counter/devices/counterX/countY/enable
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Whether channel Y counter is enabled. Valid attribute values are
boolean.
This attribute is intended to serve as a pause/unpause mechanism
for Count Y. Suppose a counter device is used to count the total
movement of a conveyor belt: this attribute allows an operator
to temporarily pause the counter, service the conveyor belt,
and then finally unpause the counter to continue where it had
left off.
What: /sys/bus/counter/devices/counterX/countY/error_noise
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Read-only attribute that indicates whether excessive noise is
present at the channel Y counter inputs.
What: /sys/bus/counter/devices/counterX/countY/function
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Count function mode of Count Y; count function evaluation is
triggered by conditions specified by the Count Y signalZ_action
attributes. The following count functions are available:
increase:
Accumulated count is incremented.
decrease:
Accumulated count is decremented.
pulse-direction:
Rising edges on signal A updates the respective count.
The input level of signal B determines direction.
quadrature x1 a:
If direction is forward, rising edges on quadrature pair
signal A updates the respective count; if the direction
is backward, falling edges on quadrature pair signal A
updates the respective count. Quadrature encoding
determines the direction.
quadrature x1 b:
If direction is forward, rising edges on quadrature pair
signal B updates the respective count; if the direction
is backward, falling edges on quadrature pair signal B
updates the respective count. Quadrature encoding
determines the direction.
quadrature x2 a:
Any state transition on quadrature pair signal A updates
the respective count. Quadrature encoding determines the
direction.
quadrature x2 b:
Any state transition on quadrature pair signal B updates
the respective count. Quadrature encoding determines the
direction.
quadrature x4:
Any state transition on either quadrature pair signals
updates the respective count. Quadrature encoding
determines the direction.
What: /sys/bus/counter/devices/counterX/countY/name
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Read-only attribute that indicates the device-specific name of
Count Y. If possible, this should match the name of the
respective channel as it appears in the device datasheet.
What: /sys/bus/counter/devices/counterX/countY/preset
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
If the counter device supports preset registers -- registers
used to load counter channels to a set count upon device-defined
preset operation trigger events -- the preset count for channel
Y is provided by this attribute.
What: /sys/bus/counter/devices/counterX/countY/preset_enable
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Whether channel Y counter preset operation is enabled. Valid
attribute values are boolean.
What: /sys/bus/counter/devices/counterX/countY/signalZ_action
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Action mode of Count Y for Signal Z. This attribute indicates
the condition of Signal Z that triggers the count function
evaluation for Count Y. The following action modes are
available:
none:
Signal does not trigger the count function. In
Pulse-Direction count function mode, this Signal is
evaluated as Direction.
rising edge:
Low state transitions to high state.
falling edge:
High state transitions to low state.
both edges:
Any state transition.
What: /sys/bus/counter/devices/counterX/name
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Read-only attribute that indicates the device-specific name of
the Counter. This should match the name of the device as it
appears in its respective datasheet.
What: /sys/bus/counter/devices/counterX/num_counts
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Read-only attribute that indicates the total number of Counts
belonging to the Counter.
What: /sys/bus/counter/devices/counterX/num_signals
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Read-only attribute that indicates the total number of Signals
belonging to the Counter.
What: /sys/bus/counter/devices/counterX/signalY/signal
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Signal data of Signal Y represented as a string.
What: /sys/bus/counter/devices/counterX/signalY/name
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Read-only attribute that indicates the device-specific name of
Signal Y. If possible, this should match the name of the
respective signal as it appears in the device datasheet.