linux_dsm_epyc7002/drivers/scsi/megaraid
Tomas Henzl bc6ac5e8c2 megaraid_sas: fix a small problem when reading state value from hw
When the driver reads state values from the hw it might happen that
different values are read in subsequent reads and this can cause problems,
this may lead to a timeout in this function and a non working adapter.

Cc: Adam Radford <aradford@gmail.com>

Signed-off-by: Tomas Henzl <thenzl@redhat.com>
Reviewed-by: Shintaro Minemoto <fj3207hq@aa.jp.fujitsu.com>
Acked-by: Sumit Saxena <sumit.saxena@lsi.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2014-05-19 13:30:59 +02:00
..
Kconfig.megaraid
Makefile
mbox_defs.h
mega_common.h
megaraid_ioctl.h
megaraid_mbox.c [SCSI] Disable WRITE SAME for RAID and virtual host adapter drivers 2013-11-29 08:48:39 +04:00
megaraid_mbox.h
megaraid_mm.c [SCSI] megaraid: missing bounds check in mimd_to_kioc() 2014-03-15 10:19:00 -07:00
megaraid_mm.h
megaraid_sas_base.c megaraid_sas: fix a small problem when reading state value from hw 2014-05-19 13:30:59 +02:00
megaraid_sas_fp.c [SCSI] megaraid_sas: Load correct raid context timeout 2014-03-15 10:19:20 -07:00
megaraid_sas_fusion.c [SCSI] megaraid_sas: Add Dell PowerEdge VRTX SR-IOV VF support 2014-03-15 10:19:21 -07:00
megaraid_sas_fusion.h [SCSI] megaraid_sas: Add Dell PowerEdge VRTX SR-IOV VF support 2014-03-15 10:19:21 -07:00
megaraid_sas.h [SCSI] megaraid_sas: Version and Changelog update 2014-03-15 10:19:21 -07:00