linux_dsm_epyc7002/include/uapi/scsi/fc/fc_els.h
Greg Kroah-Hartman e2be04c7f9 License cleanup: add SPDX license identifier to uapi header files with a license
Many user space API headers have licensing information, which is either
incomplete, badly formatted or just a shorthand for referring to the
license under which the file is supposed to be.  This makes it hard for
compliance tools to determine the correct license.

Update these files with an SPDX license identifier.  The identifier was
chosen based on the license information in the file.

GPL/LGPL licensed headers get the matching GPL/LGPL SPDX license
identifier with the added 'WITH Linux-syscall-note' exception, which is
the officially assigned exception identifier for the kernel syscall
exception:

   NOTE! This copyright does *not* cover user programs that use kernel
   services by normal system calls - this is merely considered normal use
   of the kernel, and does *not* fall under the heading of "derived work".

This exception makes it possible to include GPL headers into non GPL
code, without confusing license compliance tools.

Headers which have either explicit dual licensing or are just licensed
under a non GPL license are updated with the corresponding SPDX
identifier and the GPLv2 with syscall exception identifier.  The format
is:
        ((GPL-2.0 WITH Linux-syscall-note) OR SPDX-ID-OF-OTHER-LICENSE)

SPDX license identifiers are a legally binding shorthand, which can be
used instead of the full boiler plate text.  The update does not remove
existing license information as this has to be done on a case by case
basis and the copyright holders might have to be consulted. This will
happen in a separate step.

This patch is based on work done by Thomas Gleixner and Kate Stewart and
Philippe Ombredanne.  See the previous patch in this series for the
methodology of how this patch was researched.

Reviewed-by: Kate Stewart <kstewart@linuxfoundation.org>
Reviewed-by: Philippe Ombredanne <pombredanne@nexb.com>
Reviewed-by: Thomas Gleixner <tglx@linutronix.de>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2017-11-02 11:20:11 +01:00

833 lines
26 KiB
C

/* SPDX-License-Identifier: GPL-2.0 WITH Linux-syscall-note */
/*
* Copyright(c) 2007 Intel Corporation. All rights reserved.
*
* This program is free software; you can redistribute it and/or modify it
* under the terms and conditions of the GNU General Public License,
* version 2, as published by the Free Software Foundation.
*
* This program is distributed in the hope it will be useful, but WITHOUT
* ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or
* FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License for
* more details.
*
* You should have received a copy of the GNU General Public License along with
* this program; if not, write to the Free Software Foundation, Inc.,
* 51 Franklin St - Fifth Floor, Boston, MA 02110-1301 USA.
*
* Maintained at www.Open-FCoE.org
*/
#ifndef _FC_ELS_H_
#define _FC_ELS_H_
#include <linux/types.h>
/*
* Fibre Channel Switch - Enhanced Link Services definitions.
* From T11 FC-LS Rev 1.2 June 7, 2005.
*/
/*
* ELS Command codes - byte 0 of the frame payload
*/
enum fc_els_cmd {
ELS_LS_RJT = 0x01, /* ESL reject */
ELS_LS_ACC = 0x02, /* ESL Accept */
ELS_PLOGI = 0x03, /* N_Port login */
ELS_FLOGI = 0x04, /* F_Port login */
ELS_LOGO = 0x05, /* Logout */
ELS_ABTX = 0x06, /* Abort exchange - obsolete */
ELS_RCS = 0x07, /* read connection status */
ELS_RES = 0x08, /* read exchange status block */
ELS_RSS = 0x09, /* read sequence status block */
ELS_RSI = 0x0a, /* read sequence initiative */
ELS_ESTS = 0x0b, /* establish streaming */
ELS_ESTC = 0x0c, /* estimate credit */
ELS_ADVC = 0x0d, /* advise credit */
ELS_RTV = 0x0e, /* read timeout value */
ELS_RLS = 0x0f, /* read link error status block */
ELS_ECHO = 0x10, /* echo */
ELS_TEST = 0x11, /* test */
ELS_RRQ = 0x12, /* reinstate recovery qualifier */
ELS_REC = 0x13, /* read exchange concise */
ELS_SRR = 0x14, /* sequence retransmission request */
ELS_PRLI = 0x20, /* process login */
ELS_PRLO = 0x21, /* process logout */
ELS_SCN = 0x22, /* state change notification */
ELS_TPLS = 0x23, /* test process login state */
ELS_TPRLO = 0x24, /* third party process logout */
ELS_LCLM = 0x25, /* login control list mgmt (obs) */
ELS_GAID = 0x30, /* get alias_ID */
ELS_FACT = 0x31, /* fabric activate alias_id */
ELS_FDACDT = 0x32, /* fabric deactivate alias_id */
ELS_NACT = 0x33, /* N-port activate alias_id */
ELS_NDACT = 0x34, /* N-port deactivate alias_id */
ELS_QOSR = 0x40, /* quality of service request */
ELS_RVCS = 0x41, /* read virtual circuit status */
ELS_PDISC = 0x50, /* discover N_port service params */
ELS_FDISC = 0x51, /* discover F_port service params */
ELS_ADISC = 0x52, /* discover address */
ELS_RNC = 0x53, /* report node cap (obs) */
ELS_FARP_REQ = 0x54, /* FC ARP request */
ELS_FARP_REPL = 0x55, /* FC ARP reply */
ELS_RPS = 0x56, /* read port status block */
ELS_RPL = 0x57, /* read port list */
ELS_RPBC = 0x58, /* read port buffer condition */
ELS_FAN = 0x60, /* fabric address notification */
ELS_RSCN = 0x61, /* registered state change notification */
ELS_SCR = 0x62, /* state change registration */
ELS_RNFT = 0x63, /* report node FC-4 types */
ELS_CSR = 0x68, /* clock synch. request */
ELS_CSU = 0x69, /* clock synch. update */
ELS_LINIT = 0x70, /* loop initialize */
ELS_LSTS = 0x72, /* loop status */
ELS_RNID = 0x78, /* request node ID data */
ELS_RLIR = 0x79, /* registered link incident report */
ELS_LIRR = 0x7a, /* link incident record registration */
ELS_SRL = 0x7b, /* scan remote loop */
ELS_SBRP = 0x7c, /* set bit-error reporting params */
ELS_RPSC = 0x7d, /* report speed capabilities */
ELS_QSA = 0x7e, /* query security attributes */
ELS_EVFP = 0x7f, /* exchange virt. fabrics params */
ELS_LKA = 0x80, /* link keep-alive */
ELS_AUTH_ELS = 0x90, /* authentication ELS */
};
/*
* Initializer useful for decoding table.
* Please keep this in sync with the above definitions.
*/
#define FC_ELS_CMDS_INIT { \
[ELS_LS_RJT] = "LS_RJT", \
[ELS_LS_ACC] = "LS_ACC", \
[ELS_PLOGI] = "PLOGI", \
[ELS_FLOGI] = "FLOGI", \
[ELS_LOGO] = "LOGO", \
[ELS_ABTX] = "ABTX", \
[ELS_RCS] = "RCS", \
[ELS_RES] = "RES", \
[ELS_RSS] = "RSS", \
[ELS_RSI] = "RSI", \
[ELS_ESTS] = "ESTS", \
[ELS_ESTC] = "ESTC", \
[ELS_ADVC] = "ADVC", \
[ELS_RTV] = "RTV", \
[ELS_RLS] = "RLS", \
[ELS_ECHO] = "ECHO", \
[ELS_TEST] = "TEST", \
[ELS_RRQ] = "RRQ", \
[ELS_REC] = "REC", \
[ELS_SRR] = "SRR", \
[ELS_PRLI] = "PRLI", \
[ELS_PRLO] = "PRLO", \
[ELS_SCN] = "SCN", \
[ELS_TPLS] = "TPLS", \
[ELS_TPRLO] = "TPRLO", \
[ELS_LCLM] = "LCLM", \
[ELS_GAID] = "GAID", \
[ELS_FACT] = "FACT", \
[ELS_FDACDT] = "FDACDT", \
[ELS_NACT] = "NACT", \
[ELS_NDACT] = "NDACT", \
[ELS_QOSR] = "QOSR", \
[ELS_RVCS] = "RVCS", \
[ELS_PDISC] = "PDISC", \
[ELS_FDISC] = "FDISC", \
[ELS_ADISC] = "ADISC", \
[ELS_RNC] = "RNC", \
[ELS_FARP_REQ] = "FARP_REQ", \
[ELS_FARP_REPL] = "FARP_REPL", \
[ELS_RPS] = "RPS", \
[ELS_RPL] = "RPL", \
[ELS_RPBC] = "RPBC", \
[ELS_FAN] = "FAN", \
[ELS_RSCN] = "RSCN", \
[ELS_SCR] = "SCR", \
[ELS_RNFT] = "RNFT", \
[ELS_CSR] = "CSR", \
[ELS_CSU] = "CSU", \
[ELS_LINIT] = "LINIT", \
[ELS_LSTS] = "LSTS", \
[ELS_RNID] = "RNID", \
[ELS_RLIR] = "RLIR", \
[ELS_LIRR] = "LIRR", \
[ELS_SRL] = "SRL", \
[ELS_SBRP] = "SBRP", \
[ELS_RPSC] = "RPSC", \
[ELS_QSA] = "QSA", \
[ELS_EVFP] = "EVFP", \
[ELS_LKA] = "LKA", \
[ELS_AUTH_ELS] = "AUTH_ELS", \
}
/*
* LS_ACC payload.
*/
struct fc_els_ls_acc {
__u8 la_cmd; /* command code ELS_LS_ACC */
__u8 la_resv[3]; /* reserved */
};
/*
* ELS reject payload.
*/
struct fc_els_ls_rjt {
__u8 er_cmd; /* command code ELS_LS_RJT */
__u8 er_resv[4]; /* reserved must be zero */
__u8 er_reason; /* reason (enum fc_els_rjt_reason below) */
__u8 er_explan; /* explanation (enum fc_els_rjt_explan below) */
__u8 er_vendor; /* vendor specific code */
};
/*
* ELS reject reason codes (er_reason).
*/
enum fc_els_rjt_reason {
ELS_RJT_NONE = 0, /* no reject - not to be sent */
ELS_RJT_INVAL = 0x01, /* invalid ELS command code */
ELS_RJT_LOGIC = 0x03, /* logical error */
ELS_RJT_BUSY = 0x05, /* logical busy */
ELS_RJT_PROT = 0x07, /* protocol error */
ELS_RJT_UNAB = 0x09, /* unable to perform command request */
ELS_RJT_UNSUP = 0x0b, /* command not supported */
ELS_RJT_INPROG = 0x0e, /* command already in progress */
ELS_RJT_FIP = 0x20, /* FIP error */
ELS_RJT_VENDOR = 0xff, /* vendor specific error */
};
/*
* reason code explanation (er_explan).
*/
enum fc_els_rjt_explan {
ELS_EXPL_NONE = 0x00, /* No additional explanation */
ELS_EXPL_SPP_OPT_ERR = 0x01, /* service parameter error - options */
ELS_EXPL_SPP_ICTL_ERR = 0x03, /* service parm error - initiator ctl */
ELS_EXPL_AH = 0x11, /* invalid association header */
ELS_EXPL_AH_REQ = 0x13, /* association_header required */
ELS_EXPL_SID = 0x15, /* invalid originator S_ID */
ELS_EXPL_OXID_RXID = 0x17, /* invalid OX_ID-RX_ID combination */
ELS_EXPL_INPROG = 0x19, /* Request already in progress */
ELS_EXPL_PLOGI_REQD = 0x1e, /* N_Port login required */
ELS_EXPL_INSUF_RES = 0x29, /* insufficient resources */
ELS_EXPL_UNAB_DATA = 0x2a, /* unable to supply requested data */
ELS_EXPL_UNSUPR = 0x2c, /* Request not supported */
ELS_EXPL_INV_LEN = 0x2d, /* Invalid payload length */
ELS_EXPL_NOT_NEIGHBOR = 0x62, /* VN2VN_Port not in neighbor set */
/* TBD - above definitions incomplete */
};
/*
* Common service parameters (N ports).
*/
struct fc_els_csp {
__u8 sp_hi_ver; /* highest version supported (obs.) */
__u8 sp_lo_ver; /* highest version supported (obs.) */
__be16 sp_bb_cred; /* buffer-to-buffer credits */
__be16 sp_features; /* common feature flags */
__be16 sp_bb_data; /* b-b state number and data field sz */
union {
struct {
__be16 _sp_tot_seq; /* total concurrent sequences */
__be16 _sp_rel_off; /* rel. offset by info cat */
} sp_plogi;
struct {
__be32 _sp_r_a_tov; /* resource alloc. timeout msec */
} sp_flogi_acc;
} sp_u;
__be32 sp_e_d_tov; /* error detect timeout value */
};
#define sp_tot_seq sp_u.sp_plogi._sp_tot_seq
#define sp_rel_off sp_u.sp_plogi._sp_rel_off
#define sp_r_a_tov sp_u.sp_flogi_acc._sp_r_a_tov
#define FC_SP_BB_DATA_MASK 0xfff /* mask for data field size in sp_bb_data */
/*
* Minimum and maximum values for max data field size in service parameters.
*/
#define FC_SP_MIN_MAX_PAYLOAD FC_MIN_MAX_PAYLOAD
#define FC_SP_MAX_MAX_PAYLOAD FC_MAX_PAYLOAD
/*
* sp_features
*/
#define FC_SP_FT_NPIV 0x8000 /* multiple N_Port_ID support (FLOGI) */
#define FC_SP_FT_CIRO 0x8000 /* continuously increasing rel off (PLOGI) */
#define FC_SP_FT_CLAD 0x8000 /* clean address (in FLOGI LS_ACC) */
#define FC_SP_FT_RAND 0x4000 /* random relative offset */
#define FC_SP_FT_VAL 0x2000 /* valid vendor version level */
#define FC_SP_FT_NPIV_ACC 0x2000 /* NPIV assignment (FLOGI LS_ACC) */
#define FC_SP_FT_FPORT 0x1000 /* F port (1) vs. N port (0) */
#define FC_SP_FT_ABB 0x0800 /* alternate BB_credit management */
#define FC_SP_FT_EDTR 0x0400 /* E_D_TOV Resolution is nanoseconds */
#define FC_SP_FT_MCAST 0x0200 /* multicast */
#define FC_SP_FT_BCAST 0x0100 /* broadcast */
#define FC_SP_FT_HUNT 0x0080 /* hunt group */
#define FC_SP_FT_SIMP 0x0040 /* dedicated simplex */
#define FC_SP_FT_SEC 0x0020 /* reserved for security */
#define FC_SP_FT_CSYN 0x0010 /* clock synch. supported */
#define FC_SP_FT_RTTOV 0x0008 /* R_T_TOV value 100 uS, else 100 mS */
#define FC_SP_FT_HALF 0x0004 /* dynamic half duplex */
#define FC_SP_FT_SEQC 0x0002 /* SEQ_CNT */
#define FC_SP_FT_PAYL 0x0001 /* FLOGI payload length 256, else 116 */
/*
* Class-specific service parameters.
*/
struct fc_els_cssp {
__be16 cp_class; /* class flags */
__be16 cp_init; /* initiator flags */
__be16 cp_recip; /* recipient flags */
__be16 cp_rdfs; /* receive data field size */
__be16 cp_con_seq; /* concurrent sequences */
__be16 cp_ee_cred; /* N-port end-to-end credit */
__u8 cp_resv1; /* reserved */
__u8 cp_open_seq; /* open sequences per exchange */
__u8 _cp_resv2[2]; /* reserved */
};
/*
* cp_class flags.
*/
#define FC_CPC_VALID 0x8000 /* class valid */
#define FC_CPC_IMIX 0x4000 /* intermix mode */
#define FC_CPC_SEQ 0x0800 /* sequential delivery */
#define FC_CPC_CAMP 0x0200 /* camp-on */
#define FC_CPC_PRI 0x0080 /* priority */
/*
* cp_init flags.
* (TBD: not all flags defined here).
*/
#define FC_CPI_CSYN 0x0010 /* clock synch. capable */
/*
* cp_recip flags.
*/
#define FC_CPR_CSYN 0x0008 /* clock synch. capable */
/*
* NFC_ELS_FLOGI: Fabric login request.
* NFC_ELS_PLOGI: Port login request (same format).
*/
struct fc_els_flogi {
__u8 fl_cmd; /* command */
__u8 _fl_resvd[3]; /* must be zero */
struct fc_els_csp fl_csp; /* common service parameters */
__be64 fl_wwpn; /* port name */
__be64 fl_wwnn; /* node name */
struct fc_els_cssp fl_cssp[4]; /* class 1-4 service parameters */
__u8 fl_vend[16]; /* vendor version level */
} __attribute__((__packed__));
/*
* Process login service parameter page.
*/
struct fc_els_spp {
__u8 spp_type; /* type code or common service params */
__u8 spp_type_ext; /* type code extension */
__u8 spp_flags;
__u8 _spp_resvd;
__be32 spp_orig_pa; /* originator process associator */
__be32 spp_resp_pa; /* responder process associator */
__be32 spp_params; /* service parameters */
};
/*
* spp_flags.
*/
#define FC_SPP_OPA_VAL 0x80 /* originator proc. assoc. valid */
#define FC_SPP_RPA_VAL 0x40 /* responder proc. assoc. valid */
#define FC_SPP_EST_IMG_PAIR 0x20 /* establish image pair */
#define FC_SPP_RESP_MASK 0x0f /* mask for response code (below) */
/*
* SPP response code in spp_flags - lower 4 bits.
*/
enum fc_els_spp_resp {
FC_SPP_RESP_ACK = 1, /* request executed */
FC_SPP_RESP_RES = 2, /* unable due to lack of resources */
FC_SPP_RESP_INIT = 3, /* initialization not complete */
FC_SPP_RESP_NO_PA = 4, /* unknown process associator */
FC_SPP_RESP_CONF = 5, /* configuration precludes image pair */
FC_SPP_RESP_COND = 6, /* request completed conditionally */
FC_SPP_RESP_MULT = 7, /* unable to handle multiple SPPs */
FC_SPP_RESP_INVL = 8, /* SPP is invalid */
};
/*
* ELS_RRQ - Reinstate Recovery Qualifier
*/
struct fc_els_rrq {
__u8 rrq_cmd; /* command (0x12) */
__u8 rrq_zero[3]; /* specified as zero - part of cmd */
__u8 rrq_resvd; /* reserved */
__u8 rrq_s_id[3]; /* originator FID */
__be16 rrq_ox_id; /* originator exchange ID */
__be16 rrq_rx_id; /* responders exchange ID */
};
/*
* ELS_REC - Read exchange concise.
*/
struct fc_els_rec {
__u8 rec_cmd; /* command (0x13) */
__u8 rec_zero[3]; /* specified as zero - part of cmd */
__u8 rec_resvd; /* reserved */
__u8 rec_s_id[3]; /* originator FID */
__be16 rec_ox_id; /* originator exchange ID */
__be16 rec_rx_id; /* responders exchange ID */
};
/*
* ELS_REC LS_ACC payload.
*/
struct fc_els_rec_acc {
__u8 reca_cmd; /* accept (0x02) */
__u8 reca_zero[3]; /* specified as zero - part of cmd */
__be16 reca_ox_id; /* originator exchange ID */
__be16 reca_rx_id; /* responders exchange ID */
__u8 reca_resvd1; /* reserved */
__u8 reca_ofid[3]; /* originator FID */
__u8 reca_resvd2; /* reserved */
__u8 reca_rfid[3]; /* responder FID */
__be32 reca_fc4value; /* FC4 value */
__be32 reca_e_stat; /* ESB (exchange status block) status */
};
/*
* ELS_PRLI - Process login request and response.
*/
struct fc_els_prli {
__u8 prli_cmd; /* command */
__u8 prli_spp_len; /* length of each serv. parm. page */
__be16 prli_len; /* length of entire payload */
/* service parameter pages follow */
};
/*
* ELS_PRLO - Process logout request and response.
*/
struct fc_els_prlo {
__u8 prlo_cmd; /* command */
__u8 prlo_obs; /* obsolete, but shall be set to 10h */
__be16 prlo_len; /* payload length */
};
/*
* ELS_ADISC payload
*/
struct fc_els_adisc {
__u8 adisc_cmd;
__u8 adisc_resv[3];
__u8 adisc_resv1;
__u8 adisc_hard_addr[3];
__be64 adisc_wwpn;
__be64 adisc_wwnn;
__u8 adisc_resv2;
__u8 adisc_port_id[3];
} __attribute__((__packed__));
/*
* ELS_LOGO - process or fabric logout.
*/
struct fc_els_logo {
__u8 fl_cmd; /* command code */
__u8 fl_zero[3]; /* specified as zero - part of cmd */
__u8 fl_resvd; /* reserved */
__u8 fl_n_port_id[3];/* N port ID */
__be64 fl_n_port_wwn; /* port name */
};
/*
* ELS_RTV - read timeout value.
*/
struct fc_els_rtv {
__u8 rtv_cmd; /* command code 0x0e */
__u8 rtv_zero[3]; /* specified as zero - part of cmd */
};
/*
* LS_ACC for ELS_RTV - read timeout value.
*/
struct fc_els_rtv_acc {
__u8 rtv_cmd; /* command code 0x02 */
__u8 rtv_zero[3]; /* specified as zero - part of cmd */
__be32 rtv_r_a_tov; /* resource allocation timeout value */
__be32 rtv_e_d_tov; /* error detection timeout value */
__be32 rtv_toq; /* timeout qualifier (see below) */
};
/*
* rtv_toq bits.
*/
#define FC_ELS_RTV_EDRES (1 << 26) /* E_D_TOV resolution is nS else mS */
#define FC_ELS_RTV_RTTOV (1 << 19) /* R_T_TOV is 100 uS else 100 mS */
/*
* ELS_SCR - state change registration payload.
*/
struct fc_els_scr {
__u8 scr_cmd; /* command code */
__u8 scr_resv[6]; /* reserved */
__u8 scr_reg_func; /* registration function (see below) */
};
enum fc_els_scr_func {
ELS_SCRF_FAB = 1, /* fabric-detected registration */
ELS_SCRF_NPORT = 2, /* Nx_Port-detected registration */
ELS_SCRF_FULL = 3, /* full registration */
ELS_SCRF_CLEAR = 255, /* remove any current registrations */
};
/*
* ELS_RSCN - registered state change notification payload.
*/
struct fc_els_rscn {
__u8 rscn_cmd; /* RSCN opcode (0x61) */
__u8 rscn_page_len; /* page length (4) */
__be16 rscn_plen; /* payload length including this word */
/* followed by 4-byte generic affected Port_ID pages */
};
struct fc_els_rscn_page {
__u8 rscn_page_flags; /* event and address format */
__u8 rscn_fid[3]; /* fabric ID */
};
#define ELS_RSCN_EV_QUAL_BIT 2 /* shift count for event qualifier */
#define ELS_RSCN_EV_QUAL_MASK 0xf /* mask for event qualifier */
#define ELS_RSCN_ADDR_FMT_BIT 0 /* shift count for address format */
#define ELS_RSCN_ADDR_FMT_MASK 0x3 /* mask for address format */
enum fc_els_rscn_ev_qual {
ELS_EV_QUAL_NONE = 0, /* unspecified */
ELS_EV_QUAL_NS_OBJ = 1, /* changed name server object */
ELS_EV_QUAL_PORT_ATTR = 2, /* changed port attribute */
ELS_EV_QUAL_SERV_OBJ = 3, /* changed service object */
ELS_EV_QUAL_SW_CONFIG = 4, /* changed switch configuration */
ELS_EV_QUAL_REM_OBJ = 5, /* removed object */
};
enum fc_els_rscn_addr_fmt {
ELS_ADDR_FMT_PORT = 0, /* rscn_fid is a port address */
ELS_ADDR_FMT_AREA = 1, /* rscn_fid is a area address */
ELS_ADDR_FMT_DOM = 2, /* rscn_fid is a domain address */
ELS_ADDR_FMT_FAB = 3, /* anything on fabric may have changed */
};
/*
* ELS_RNID - request Node ID.
*/
struct fc_els_rnid {
__u8 rnid_cmd; /* RNID opcode (0x78) */
__u8 rnid_resv[3]; /* reserved */
__u8 rnid_fmt; /* data format */
__u8 rnid_resv2[3]; /* reserved */
};
/*
* Node Identification Data formats (rnid_fmt)
*/
enum fc_els_rnid_fmt {
ELS_RNIDF_NONE = 0, /* no specific identification data */
ELS_RNIDF_GEN = 0xdf, /* general topology discovery format */
};
/*
* ELS_RNID response.
*/
struct fc_els_rnid_resp {
__u8 rnid_cmd; /* response code (LS_ACC) */
__u8 rnid_resv[3]; /* reserved */
__u8 rnid_fmt; /* data format */
__u8 rnid_cid_len; /* common ID data length */
__u8 rnid_resv2; /* reserved */
__u8 rnid_sid_len; /* specific ID data length */
};
struct fc_els_rnid_cid {
__be64 rnid_wwpn; /* N port name */
__be64 rnid_wwnn; /* node name */
};
struct fc_els_rnid_gen {
__u8 rnid_vend_id[16]; /* vendor-unique ID */
__be32 rnid_atype; /* associated type (see below) */
__be32 rnid_phys_port; /* physical port number */
__be32 rnid_att_nodes; /* number of attached nodes */
__u8 rnid_node_mgmt; /* node management (see below) */
__u8 rnid_ip_ver; /* IP version (see below) */
__be16 rnid_prot_port; /* UDP / TCP port number */
__be32 rnid_ip_addr[4]; /* IP address */
__u8 rnid_resvd[2]; /* reserved */
__be16 rnid_vend_spec; /* vendor-specific field */
};
enum fc_els_rnid_atype {
ELS_RNIDA_UNK = 0x01, /* unknown */
ELS_RNIDA_OTHER = 0x02, /* none of the following */
ELS_RNIDA_HUB = 0x03,
ELS_RNIDA_SWITCH = 0x04,
ELS_RNIDA_GATEWAY = 0x05,
ELS_RNIDA_CONV = 0x06, /* Obsolete, do not use this value */
ELS_RNIDA_HBA = 0x07, /* Obsolete, do not use this value */
ELS_RNIDA_PROXY = 0x08, /* Obsolete, do not use this value */
ELS_RNIDA_STORAGE = 0x09,
ELS_RNIDA_HOST = 0x0a,
ELS_RNIDA_SUBSYS = 0x0b, /* storage subsystem (e.g., RAID) */
ELS_RNIDA_ACCESS = 0x0e, /* access device (e.g. media changer) */
ELS_RNIDA_NAS = 0x11, /* NAS server */
ELS_RNIDA_BRIDGE = 0x12, /* bridge */
ELS_RNIDA_VIRT = 0x13, /* virtualization device */
ELS_RNIDA_MF = 0xff, /* multifunction device (bits below) */
ELS_RNIDA_MF_HUB = 1UL << 31, /* hub */
ELS_RNIDA_MF_SW = 1UL << 30, /* switch */
ELS_RNIDA_MF_GW = 1UL << 29, /* gateway */
ELS_RNIDA_MF_ST = 1UL << 28, /* storage */
ELS_RNIDA_MF_HOST = 1UL << 27, /* host */
ELS_RNIDA_MF_SUB = 1UL << 26, /* storage subsystem */
ELS_RNIDA_MF_ACC = 1UL << 25, /* storage access dev */
ELS_RNIDA_MF_WDM = 1UL << 24, /* wavelength division mux */
ELS_RNIDA_MF_NAS = 1UL << 23, /* NAS server */
ELS_RNIDA_MF_BR = 1UL << 22, /* bridge */
ELS_RNIDA_MF_VIRT = 1UL << 21, /* virtualization device */
};
enum fc_els_rnid_mgmt {
ELS_RNIDM_SNMP = 0,
ELS_RNIDM_TELNET = 1,
ELS_RNIDM_HTTP = 2,
ELS_RNIDM_HTTPS = 3,
ELS_RNIDM_XML = 4, /* HTTP + XML */
};
enum fc_els_rnid_ipver {
ELS_RNIDIP_NONE = 0, /* no IP support or node mgmt. */
ELS_RNIDIP_V4 = 1, /* IPv4 */
ELS_RNIDIP_V6 = 2, /* IPv6 */
};
/*
* ELS RPL - Read Port List.
*/
struct fc_els_rpl {
__u8 rpl_cmd; /* command */
__u8 rpl_resv[5]; /* reserved - must be zero */
__be16 rpl_max_size; /* maximum response size or zero */
__u8 rpl_resv1; /* reserved - must be zero */
__u8 rpl_index[3]; /* starting index */
};
/*
* Port number block in RPL response.
*/
struct fc_els_pnb {
__be32 pnb_phys_pn; /* physical port number */
__u8 pnb_resv; /* reserved */
__u8 pnb_port_id[3]; /* port ID */
__be64 pnb_wwpn; /* port name */
};
/*
* RPL LS_ACC response.
*/
struct fc_els_rpl_resp {
__u8 rpl_cmd; /* ELS_LS_ACC */
__u8 rpl_resv1; /* reserved - must be zero */
__be16 rpl_plen; /* payload length */
__u8 rpl_resv2; /* reserved - must be zero */
__u8 rpl_llen[3]; /* list length */
__u8 rpl_resv3; /* reserved - must be zero */
__u8 rpl_index[3]; /* starting index */
struct fc_els_pnb rpl_pnb[1]; /* variable number of PNBs */
};
/*
* Link Error Status Block.
*/
struct fc_els_lesb {
__be32 lesb_link_fail; /* link failure count */
__be32 lesb_sync_loss; /* loss of synchronization count */
__be32 lesb_sig_loss; /* loss of signal count */
__be32 lesb_prim_err; /* primitive sequence error count */
__be32 lesb_inv_word; /* invalid transmission word count */
__be32 lesb_inv_crc; /* invalid CRC count */
};
/*
* ELS RPS - Read Port Status Block request.
*/
struct fc_els_rps {
__u8 rps_cmd; /* command */
__u8 rps_resv[2]; /* reserved - must be zero */
__u8 rps_flag; /* flag - see below */
__be64 rps_port_spec; /* port selection */
};
enum fc_els_rps_flag {
FC_ELS_RPS_DID = 0x00, /* port identified by D_ID of req. */
FC_ELS_RPS_PPN = 0x01, /* port_spec is physical port number */
FC_ELS_RPS_WWPN = 0x02, /* port_spec is port WWN */
};
/*
* ELS RPS LS_ACC response.
*/
struct fc_els_rps_resp {
__u8 rps_cmd; /* command - LS_ACC */
__u8 rps_resv[2]; /* reserved - must be zero */
__u8 rps_flag; /* flag - see below */
__u8 rps_resv2[2]; /* reserved */
__be16 rps_status; /* port status - see below */
struct fc_els_lesb rps_lesb; /* link error status block */
};
enum fc_els_rps_resp_flag {
FC_ELS_RPS_LPEV = 0x01, /* L_port extension valid */
};
enum fc_els_rps_resp_status {
FC_ELS_RPS_PTP = 1 << 5, /* point-to-point connection */
FC_ELS_RPS_LOOP = 1 << 4, /* loop mode */
FC_ELS_RPS_FAB = 1 << 3, /* fabric present */
FC_ELS_RPS_NO_SIG = 1 << 2, /* loss of signal */
FC_ELS_RPS_NO_SYNC = 1 << 1, /* loss of synchronization */
FC_ELS_RPS_RESET = 1 << 0, /* in link reset protocol */
};
/*
* ELS LIRR - Link Incident Record Registration request.
*/
struct fc_els_lirr {
__u8 lirr_cmd; /* command */
__u8 lirr_resv[3]; /* reserved - must be zero */
__u8 lirr_func; /* registration function */
__u8 lirr_fmt; /* FC-4 type of RLIR requested */
__u8 lirr_resv2[2]; /* reserved - must be zero */
};
enum fc_els_lirr_func {
ELS_LIRR_SET_COND = 0x01, /* set - conditionally receive */
ELS_LIRR_SET_UNCOND = 0x02, /* set - unconditionally receive */
ELS_LIRR_CLEAR = 0xff /* clear registration */
};
/*
* ELS SRL - Scan Remote Loop request.
*/
struct fc_els_srl {
__u8 srl_cmd; /* command */
__u8 srl_resv[3]; /* reserved - must be zero */
__u8 srl_flag; /* flag - see below */
__u8 srl_flag_param[3]; /* flag parameter */
};
enum fc_els_srl_flag {
FC_ELS_SRL_ALL = 0x00, /* scan all FL ports */
FC_ELS_SRL_ONE = 0x01, /* scan specified loop */
FC_ELS_SRL_EN_PER = 0x02, /* enable periodic scanning (param) */
FC_ELS_SRL_DIS_PER = 0x03, /* disable periodic scanning */
};
/*
* ELS RLS - Read Link Error Status Block request.
*/
struct fc_els_rls {
__u8 rls_cmd; /* command */
__u8 rls_resv[4]; /* reserved - must be zero */
__u8 rls_port_id[3]; /* port ID */
};
/*
* ELS RLS LS_ACC Response.
*/
struct fc_els_rls_resp {
__u8 rls_cmd; /* ELS_LS_ACC */
__u8 rls_resv[3]; /* reserved - must be zero */
struct fc_els_lesb rls_lesb; /* link error status block */
};
/*
* ELS RLIR - Registered Link Incident Report.
* This is followed by the CLIR and the CLID, described below.
*/
struct fc_els_rlir {
__u8 rlir_cmd; /* command */
__u8 rlir_resv[3]; /* reserved - must be zero */
__u8 rlir_fmt; /* format (FC4-type if type specific) */
__u8 rlir_clr_len; /* common link incident record length */
__u8 rlir_cld_len; /* common link incident desc. length */
__u8 rlir_slr_len; /* spec. link incident record length */
};
/*
* CLIR - Common Link Incident Record Data. - Sent via RLIR.
*/
struct fc_els_clir {
__be64 clir_wwpn; /* incident port name */
__be64 clir_wwnn; /* incident port node name */
__u8 clir_port_type; /* incident port type */
__u8 clir_port_id[3]; /* incident port ID */
__be64 clir_conn_wwpn; /* connected port name */
__be64 clir_conn_wwnn; /* connected node name */
__be64 clir_fab_name; /* fabric name */
__be32 clir_phys_port; /* physical port number */
__be32 clir_trans_id; /* transaction ID */
__u8 clir_resv[3]; /* reserved */
__u8 clir_ts_fmt; /* time stamp format */
__be64 clir_timestamp; /* time stamp */
};
/*
* CLIR clir_ts_fmt - time stamp format values.
*/
enum fc_els_clir_ts_fmt {
ELS_CLIR_TS_UNKNOWN = 0, /* time stamp field unknown */
ELS_CLIR_TS_SEC_FRAC = 1, /* time in seconds and fractions */
ELS_CLIR_TS_CSU = 2, /* time in clock synch update format */
};
/*
* Common Link Incident Descriptor - sent via RLIR.
*/
struct fc_els_clid {
__u8 clid_iq; /* incident qualifier flags */
__u8 clid_ic; /* incident code */
__be16 clid_epai; /* domain/area of ISL */
};
/*
* CLID incident qualifier flags.
*/
enum fc_els_clid_iq {
ELS_CLID_SWITCH = 0x20, /* incident port is a switch node */
ELS_CLID_E_PORT = 0x10, /* incident is an ISL (E) port */
ELS_CLID_SEV_MASK = 0x0c, /* severity 2-bit field mask */
ELS_CLID_SEV_INFO = 0x00, /* report is informational */
ELS_CLID_SEV_INOP = 0x08, /* link not operational */
ELS_CLID_SEV_DEG = 0x04, /* link degraded but operational */
ELS_CLID_LASER = 0x02, /* subassembly is a laser */
ELS_CLID_FRU = 0x01, /* format can identify a FRU */
};
/*
* CLID incident code.
*/
enum fc_els_clid_ic {
ELS_CLID_IC_IMPL = 1, /* implicit incident */
ELS_CLID_IC_BER = 2, /* bit-error-rate threshold exceeded */
ELS_CLID_IC_LOS = 3, /* loss of synch or signal */
ELS_CLID_IC_NOS = 4, /* non-operational primitive sequence */
ELS_CLID_IC_PST = 5, /* primitive sequence timeout */
ELS_CLID_IC_INVAL = 6, /* invalid primitive sequence */
ELS_CLID_IC_LOOP_TO = 7, /* loop initialization time out */
ELS_CLID_IC_LIP = 8, /* receiving LIP */
};
#endif /* _FC_ELS_H_ */