Most of the mv88e6xxx switches have the PHYs at address 0, 1, 2, ...
The 6341 however has the PHYs at 0x10, 0x11, 0x12. Add a parameter to
the info structure for this base address.
Testing of 6f88284f3b ("net: dsa: mv88e6xxx: Add MDIO interrupts for
internal PHYs") was performed on the 6341. So it works only on the
6341. Use this base information to correctly set the interrupt.
Fixes: 6f88284f3b ("net: dsa: mv88e6xxx: Add MDIO interrupts for internal PHYs")
Signed-off-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>