mirror of
https://github.com/AuxXxilium/linux_dsm_epyc7002.git
synced 2024-12-28 11:18:45 +07:00
7ba03c2599
Add compatible strings for AP806 and CP110 that are part of the Armada 8k/7k line of SoCs. Add a note on the differences in the size of the control area in different bindings. This is an existing difference between the Armada 375 binding and the other boards already supported. The new AP806 and CP110 bindings are similar to the existing Armada 375 in this regard. Signed-off-by: Baruch Siach <baruch@tkos.co.il> [<miquel.raynal@free-electrons.com>: reword, additional details] Signed-off-by: Miquel Raynal <miquel.raynal@free-electrons.com> Reviewed-by: Rob Herring <robh@kernel.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
37 lines
1.1 KiB
Plaintext
37 lines
1.1 KiB
Plaintext
* Marvell Armada 370/375/380/XP thermal management
|
|
|
|
Required properties:
|
|
|
|
- compatible: Should be set to one of the following:
|
|
* marvell,armada370-thermal
|
|
* marvell,armada375-thermal
|
|
* marvell,armada380-thermal
|
|
* marvell,armadaxp-thermal
|
|
* marvell,armada-ap806-thermal
|
|
* marvell,armada-cp110-thermal
|
|
|
|
- reg: Device's register space.
|
|
Two entries are expected, see the examples below. The first one points
|
|
to the status register (4B). The second one points to the control
|
|
registers (8B).
|
|
Note: The compatibles marvell,armada370-thermal,
|
|
marvell,armada380-thermal, and marvell,armadaxp-thermal must point to
|
|
"control MSB/control 1", with size of 4 (deprecated binding), or point
|
|
to "control LSB/control 0" with size of 8 (current binding). All other
|
|
compatibles must point to "control LSB/control 0" with size of 8.
|
|
|
|
Examples:
|
|
|
|
/* Legacy bindings */
|
|
thermal@d0018300 {
|
|
compatible = "marvell,armada370-thermal";
|
|
reg = <0xd0018300 0x4
|
|
0xd0018304 0x4>;
|
|
};
|
|
|
|
ap_thermal: thermal@6f8084 {
|
|
compatible = "marvell,armada-ap806-thermal";
|
|
reg = <0x6f808C 0x4>,
|
|
<0x6f8084 0x8>;
|
|
};
|