mirror of
https://github.com/AuxXxilium/linux_dsm_epyc7002.git
synced 2024-12-18 09:58:27 +07:00
65afb4c8e7
Driver obtains PWM and tachometers registers location according to the system configuration and creates FAN/PWM hwmon objects and a cooling device. PWM and tachometers are controlled through the on-board programmable device, which exports its register map. This device could be attached to any bus type, for which register mapping is supported. Single instance is created with one PWM control, up to 12 tachometers and one cooling device. It could be as many instances as programmable device supports. Currently driver will be activated from the Mellanox platform driver: drivers/platform/x86/mlx-platform.c. For the future ARM based systems it could be activated from the ARM platform module. Signed-off-by: Vadim Pasternak <vadimp@mellanox.com> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
61 lines
2.1 KiB
Plaintext
61 lines
2.1 KiB
Plaintext
Kernel driver mlxreg-fan
|
|
========================
|
|
|
|
Provides FAN control for the next Mellanox systems:
|
|
QMB700, equipped with 40x200GbE InfiniBand ports;
|
|
MSN3700, equipped with 32x200GbE or 16x400GbE Ethernet ports;
|
|
MSN3410, equipped with 6x400GbE plus 48x50GbE Ethernet ports;
|
|
MSN3800, equipped with 64x1000GbE Ethernet ports;
|
|
These are the Top of the Rack systems, equipped with Mellanox switch
|
|
board with Mellanox Quantum or Spectrume-2 devices.
|
|
FAN controller is implemented by the programmable device logic.
|
|
|
|
The default registers offsets set within the programmable device is as
|
|
following:
|
|
- pwm1 0xe3
|
|
- fan1 (tacho1) 0xe4
|
|
- fan2 (tacho2) 0xe5
|
|
- fan3 (tacho3) 0xe6
|
|
- fan4 (tacho4) 0xe7
|
|
- fan5 (tacho5) 0xe8
|
|
- fan6 (tacho6) 0xe9
|
|
- fan7 (tacho7) 0xea
|
|
- fan8 (tacho8) 0xeb
|
|
- fan9 (tacho9) 0xec
|
|
- fan10 (tacho10) 0xed
|
|
- fan11 (tacho11) 0xee
|
|
- fan12 (tacho12) 0xef
|
|
This setup can be re-programmed with other registers.
|
|
|
|
Author: Vadim Pasternak <vadimp@mellanox.com>
|
|
|
|
Description
|
|
-----------
|
|
|
|
The driver implements a simple interface for driving a fan connected to
|
|
a PWM output and tachometer inputs.
|
|
This driver obtains PWM and tachometers registers location according to
|
|
the system configuration and creates FAN/PWM hwmon objects and a cooling
|
|
device. PWM and tachometers are sensed through the on-board programmable
|
|
device, which exports its register map. This device could be attached to
|
|
any bus type, for which register mapping is supported.
|
|
Single instance is created with one PWM control, up to 12 tachometers and
|
|
one cooling device. It could be as many instances as programmable device
|
|
supports.
|
|
The driver exposes the fan to the user space through the hwmon's and
|
|
thermal's sysfs interfaces.
|
|
|
|
/sys files in hwmon subsystem
|
|
-----------------------------
|
|
|
|
fan[1-12]_fault - RO files for tachometers TACH1-TACH12 fault indication
|
|
fan[1-12]_input - RO files for tachometers TACH1-TACH12 input (in RPM)
|
|
pwm1 - RW file for fan[1-12] target duty cycle (0..255)
|
|
|
|
/sys files in thermal subsystem
|
|
-------------------------------
|
|
|
|
cur_state - RW file for current cooling state of the cooling device
|
|
(0..max_state)
|
|
max_state - RO file for maximum cooling state of the cooling device
|