linux_dsm_epyc7002/Documentation/devicetree/bindings/pwm/renesas,tpu-pwm.txt
Geert Uytterhoeven 204e17baa6 dt-bindings: pwm: renesas-tpu: Correct SoC part numbers and family names
R8A73A4 (not R8A77A4) is R-Mobile APE6,
R8A7740 is R-Mobile (not R-Car) A1.

Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be>
Acked-by: Simon Horman <horms+renesas@verge.net.au>
Reviewed-by: Rob Herring <robh@kernel.org>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
2018-03-27 23:59:43 +02:00

30 lines
1.1 KiB
Plaintext

* Renesas R-Car Timer Pulse Unit PWM Controller
Required Properties:
- compatible: should be one of the following.
- "renesas,tpu-r8a73a4": for R8A73A4 (R-Mobile APE6) compatible PWM controller.
- "renesas,tpu-r8a7740": for R8A7740 (R-Mobile A1) compatible PWM controller.
- "renesas,tpu-r8a7743": for R8A7743 (RZ/G1M) compatible PWM controller.
- "renesas,tpu-r8a7745": for R8A7745 (RZ/G1E) compatible PWM controller.
- "renesas,tpu-r8a7790": for R8A7790 (R-Car H2) compatible PWM controller.
- "renesas,tpu": for generic R-Car and RZ/G1 TPU PWM controller.
- reg: Base address and length of each memory resource used by the PWM
controller hardware module.
- #pwm-cells: should be 3. See pwm.txt in this directory for a description of
the cells format. The only third cell flag supported by this binding is
PWM_POLARITY_INVERTED.
Please refer to pwm.txt in this directory for details of the common PWM bindings
used by client devices.
Example: R8A7740 (R-Mobile A1) TPU controller node
tpu: pwm@e6600000 {
compatible = "renesas,tpu-r8a7740", "renesas,tpu";
reg = <0xe6600000 0x148>;
#pwm-cells = <3>;
};