Currently the transmit_(attempt_)done and received_msg functions set
the timestamp themselves. For the upcoming low-level pin API we need
to pass this as an argument instead. So make _ts variants that allow
the caller to specify the timestamp.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Reviewed-by: Maxime Ripard <maxime.ripard@free-electrons.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
Kernel logging messes up the upcoming low-level CEC monitoring support
which is very time-sensitive. So change the debug level of this message
but keep a counter that is shown in the debugfs status log.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Reviewed-by: Maxime Ripard <maxime.ripard@free-electrons.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
The transmit code would increase the sequence number first thing, even though
CEC_TRANSMIT would return an error due to a malformatted cec_msg struct later
on.
While valid behavior, this had the disadvantage of producing holes in the
sequence list that made debugging harder.
Only increase the sequence number when the whole message is validated.
When debugging (i.e. with cec-ctl -M) the sequence numbering is now nicely
increasing by 1 per message.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
The CEC version, vendor ID and OSD name were not cleared when clearing the
current set of logical addresses. This was unexpected and somewhat confusing,
so reset all these fields to their default values. Also document this since
the documentation wasn't quite clear either.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
Add a new capability CEC_CAP_NEEDS_HPD. If this capability is set
then the hardware can only use CEC if the HDMI Hotplug Detect pin
is high. Such hardware cannot handle the corner case in the CEC specification
where it is possible to transmit messages even if no hotplug signal is
present (needed for some displays that turn off the HPD when in standby,
but still have CEC enabled).
Typically hardware that needs this capability have the HPD wired to the CEC
block, often to a 'power' or 'active' pin.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
A simpler variant of cec_transmit_done to be used where the HW does
just a single attempt at a transmit. So if the status indicates an
error, then the corresponding error count will always be 1 and this
function figures that out based on the status argument.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
This function simplifies the integration of CEC in DRM drivers.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
- use __func__ instead of writing the full function name
- drop debug message in cec_config_log_addr since the same information
will be reported later
- use debug level 1 for errors and infrequent events, use level 2 for
debugging CEC message traffic
- log when a transmit is retried, very useful to know when debugging
- debug messages now all start with lower case
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
Just depend on DEBUG_FS, no need to invent a new kernel config.
Especially since CEC can be enabled by drm without enabling
MEDIA_SUPPORT.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
Add an explicit config option to select whether the CEC remote control
messages are to be passed on to the RC subsystem or not.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
Feature Abort shouldn't be sent in reply to messages from Unregistered,
since that would make it a broadcast message.
Signed-off-by: Hans Verkuil <hansverk@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
When validating the struct cec_s_log_addrs input a debug message is printed
for all except two of the 'return -EINVAL' paths.
Also log the reason for the missing two paths.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
Several error paths didn't log why an error was returned. Add this.
Also handle the corner case of "adapter is unconfigured AND the message
is from Unregistered to TV AND reply is non-zero" separately and return
EINVAL in that case, since it really is an invalid value and not an
unconfigured CEC device.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
The hardcoded function name is actually wrong. Use __func__ instead.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
The CEC specifications explicitly allows you to send poll messages and
Image/Text View On messages to a TV, even when unconfigured (i.e. there is
no hotplug signal detected). Some TVs will pull the HPD low when switching
to another input, or when going into standby, but CEC should still be
allowed to wake up such a display.
Add support for sending messages with initiator 0xf (Unregistered) and
destination 0 (TV) when no physical address is present.
This also required another change: the CEC adapter has to stay enabled as
long as 1) the CEC device is configured or 2) at least one filehandle is open
for the CEC device.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
When the adapter is unloaded or unconfigured, then all transmits and
pending waits should be flushed.
Move this code into its own function and improve the code that cancels
delayed work to avoid having to unlock adap->lock.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
Poll messages that are used to allocate a logical address should
use the same initiator as the destination. Instead, it expected that
the initiator was 0xf which is not according to the standard.
This also had consequences for the message checks in cec_transmit_msg_fh
that incorrectly rejected poll messages with the same initiator and
destination.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
Due to an incorrect condition the last_la used for the initial attempt at
claiming a logical address could be wrong.
The last_la wasn't converted to a mask when ANDing with type2mask, so that
test was broken.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
This race was discovered by running cec-compliance -A with the cec module debug
parameter set to 2: suddenly the test would fail.
It turns out that this happens when the test configures the adapter in
non-blocking mode, then it waits for the CEC_EVENT_STATE_CHANGE event and once
the event is received it unconfigures the adapter.
What happened was that the unconfigure was executed while the configure was
still transmitting the Report Features and Report Physical Address messages.
This messed up the internal state of the cec_adapter.
The fix is to transmit those messages with the adap->lock mutex held (this will
just queue them up in the internal transmit queue, and not actually transmit
anything yet). Only unlock the mutex once everything is done. The main thread
will dequeue the messages from the internal transmit queue and transmit them
one by one, unless an unconfigure was done, and in that case any messages are
just dropped.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
It's only a small function and this makes it easier to switch to
transmitting the message with adap->lock held in the next patch.
Signed-off-by: Hans Verkuil <hansverk@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
The fill function just fills in the cec_msg struct, it doesn't transmit
the message. This is now done explicitly.
This makes it possible to switch to transmitting this message with adap->lock
held.
Signed-off-by: Hans Verkuil <hansverk@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
The loop that sets the unused logical addresses to INVALID should be
done before 'configured' is set to true. This ensures that cec_log_addrs
is consistent before it will be used.
Signed-off-by: Hans Verkuil <hansverk@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
This is a 2.0 only message, so it should return Feature Abort if the
adapter is configured for CEC version 1.4.
Right now it does nothing, which means that the sender will time out.
Signed-off-by: Hans Verkuil <hansverk@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
When a pending message was canceled (e.g. due to a timeout), then the
old tx_status info was overwritten instead of ORed. The same happened
with the tx_error_cnt field. So just modify them instead of overwriting
them.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
In the (very) small print of the REPORT_CURRENT_LATENCY message there is a
line that says that the last byte of the message (audio out delay) is only
present if the 'audio out compensated' value is 3.
I missed this, and so if this message was sent with a total length of 6 (i.e.
without the audio out delay byte), then it was rejected by the framework
since a minimum length of 7 was expected.
Fix this minimum length check and update the wrappers in cec-funcs.h to do
the right thing based on the message length.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
Some CEC adapters will receive messages that they initiated. Add a
check that will ignore such messages.
Most hardware behaves correctly in this respect, but I have seen
adapters that don't, so just filter this out in the framework.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
Make sure the TX counters are zeroed in the cec_msg struct.
Non-zero TX counters make no sense when a message is received,
and applications should not see non-zero values here.
Signed-off-by: Hans Verkuil <hansverk@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
An inner for-loop reused the outer loop variable. This was
only noticeable with CEC adapters supporting more than one
logical address.
Signed-off-by: Hans Verkuil <hansverk@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
The CEC_MSG_FL_REPLY_TO_FOLLOWERS message flag only makes sense for transmitted
messages where you want to wait for the reply.
Clear the flag in all other cases.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
The last open issues have been addressed, so it is time to move
this out of staging and into the mainline and to move the public
cec headers to include/uapi/linux.
Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>