cleanup patch.
Use new __packed annotation in drivers/net/
Signed-off-by: Eric Dumazet <eric.dumazet@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The main differences compared to the MSCAN on the MPC5200 are:
- More flexibility in choosing the CAN source clock and frequency:
Three different clock sources can be selected: "ip", "ref" or "sys".
For the latter two, a clock divider can be defined as well. If the
clock source is not specified by the device tree, we first try to
find an optimal CAN source clock based on the system clock. If that
is not possible, the reference clock will be used.
- The behavior of bus-off recovery is configurable:
To comply with the usual handling of Socket-CAN bus-off recovery,
"recovery on request" is selected (instead of automatic recovery).
Note that only MPC5121 Rev. 2 and later is supported.
Signed-off-by: Wolfgang Grandegger <wg@denx.de>
Reviewed-by: Wolfram Sang <w.sang@pengutronix.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
Not all hardcoded values have been replaced as this made the code quite
unreadable. IMHO this compromise serves the purpose of readability.
Signed-off-by: Wolfram Sang <w.sang@pengutronix.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
- use extern where apropriate
- don't export symbols
Signed-off-by: Wolfram Sang <w.sang@pengutronix.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
Taken from socketcan-svn, fixed remaining todos, cleaned up, tested with a
phyCORE-MPC5200B-IO and a custom board.
Signed-off-by: Wolfram Sang <w.sang@pengutronix.de>
Cc: Wolfgang Grandegger <wg@grandegger.com>
Cc: Grant Likely <grant.likely@secretlab.ca>
Cc: David Miller <davem@davemloft.net>
Signed-off-by: David S. Miller <davem@davemloft.net>