Commit Graph

2 Commits

Author SHA1 Message Date
Ooi, Joyce
4c4480aad0 HID: sensor: fix attributes in HID sensor interface
User is unable to access to input-X-yyy and feature-X-yyy where
X is a hex value and more than 9 (e.g. input-a-yyy, feature-b-yyy) in HID
sensor custom sysfs interface.
This is because when creating the attribute, the attribute index is
written to using %x (hex). However, when reading and writing values into
the attribute, the attribute index is scanned using %d (decimal). Hence,
user is unable to access to attributes with index in hex values
(e.g. 'a', 'b', 'c') but able to access to attributes with index in
decimal values (e.g. 1, 2, 3,..).
This fix will change input-%d-%x-%s and feature-%d-%x-%s to input-%x-%x-%s
and feature-%x-%x-%s in show_values() and store_values() accordingly.

Signed-off-by: Ooi, Joyce <joyce.ooi@intel.com>
Reviewed-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Acked-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2016-11-05 16:56:09 +01:00
Srinivas Pandruvada
4a7de0519d HID: sensor: Custom and Generic sensor support
HID Sensor Spec defines two usage ids for custom sensors

	HID_USAGE_SENSOR_TYPE_OTHER_CUSTOM (0x09, 0xE1)
	HID_USAGE_SENSOR_TYPE_OTHER_GENERIC(0x09, 0xE2)

	In addition the standard also defines usage ids for custom fields.
The purpose of these sensors is to extend the functionality or provide a way to
obfuscate the data being communicated by a sensor. Without knowing the mapping
between the data and its encapsulated form, it is difficult for an driver to
determine what data is being communicated by the sensor.  This allows some
differentiating use cases, where vendor can provide applications.  Since these
can't be represented by standard sensor interfaces like IIO, we present these
as fields with

- type (input/output)
- units
- min/max
- get/set value

In addition an dev interface to transfer report events. Details about this
interface is described in /Documentation/hid/hid-sensor.txt.  Manufacturers
should not use these ids for any standard sensors, otherwise the the
product/vendor id can be added to black list.

Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Reviewed-by: Jonathan Cameron <jic23@kernel.org>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2015-04-10 22:22:55 +02:00