Jiri Kosina
179023e6af Merge branches 'for-4.8/upstream-fixes', 'for-4.9/alps', 'for-4.9/hid-input', 'for-4.9/intel-ish', 'for-4.9/kye-uclogic-waltop-fixes', 'for-4.9/logitech', 'for-4.9/sony', 'for-4.9/upstream' and 'for-4.9/wacom' into for-linus 2016-10-07 09:59:48 +02:00
Jason Gerecke
003f50ab67 HID: wacom: Update last_slot_field during pre_report phase
If a touchscreen contains both multitouch and single-touch reports in its
descriptor in that order, the driver may overwrite information it saved
about the format of the multitouch report. This can cause the report
processing code to get tripped up and send an incorrect event stream to
userspace.

In particular, this can cause last_slot_field to be overwritten with the
result that the driver prematurely assumes it has finished processing a
slot and sending the ABS_MT_SLOT event at the wrong point in time,
associating events for the current contact with the following contact
instead.

To prevent this from occurring, we update the value of last_slot_field
durring the pre_report phase to ensure that it is correct for the report
that is to be processed.

Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Reviewed-by: Ping Cheng <pingc@wacom.com>
Reviewed-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2016-08-11 22:37:13 +02:00
Ping Cheng
1924e05e60 HID: wacom - add touch_arbitration parameter to wacom module
Touch arbitration is always on in wacom.ko. However, there are
touch enabled applications use both pen and touch simultaneously.
We should provide an option for userland to decide if they want
arbitration on or off.

This patch sets default touch_arbitration to on since most userland
apps are not ready to process pen and touch events simultaneously.
In the future, when userland is ready to accept pen and touch events
together, we will switch default touch_arbitration to off.

Tested-by: Peter Hutterer <peter.hutterer@who-t.net>
Signed-off-by: Ping Cheng <pingc@wacom.com>
Reviewed-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2016-08-10 11:46:26 +02:00
Jason Gerecke
41372d5d40 HID: wacom: Augment 'oVid' and 'oPid' with heuristics for HID_GENERIC
The 'oVid' and 'oPid' variables used by wacom_are_sibling are a hacky
solution to the problem of the driver historically having few good
heuristics to use in determining if two devices should be considered
siblings or not. While it works well enough for explicitly supported
devices, it offers no help for HID_GENERIC devices. Now that we have
a bit more information (e.g. direct/indirect) available to us though,
we should make use of it it to improve the pairing of such devices.

Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Reviewed-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2016-08-10 11:44:28 +02:00
Jason Gerecke
e5bc8eb1b0 HID: wacom: Add WACOM_DEVICETYPE_DIRECT for Cintiqs and similar
"Direct" input devices like Cintiqs and Tablet PCs set the INPUT_PROP_DIRECT
property to notify userspace that the sensor and screen are overlaid. This
information can also be useful elsewhere within the kernel driver, however,
so we introduce a new WACOM_DEVICETYPE_DIRECT that signals this to other
kernel code.

Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Reviewed-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2016-08-10 11:44:28 +02:00
Benjamin Tissoires
6a06281e2b HID: wacom: leds: handle Cintiq 24HD leds buttons
The 24HD has 1 button per LED (first three buttons of each group).
We need a special treatment for them as it's not a uniq button that
switches between the LEDs.

Signed-off-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Acked-by: Ping Cheng <pingc@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2016-08-05 13:39:21 +02:00
Benjamin Tissoires
5a0fe8abd1 HID: wacom: leds: make sure Cintiq 21UX2 and 24HD control the right LEDs
The code for 21UX2 and 24HD makes the LED group 1 on the left, and
the group 0 on the right. The buttons are ordered in the other way,
but libwacom already exports those that way. So we simply can't reassign
LED group 0 to the left buttons, and have to quirk the incoming data...

Signed-off-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Acked-by: Ping Cheng <pingc@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2016-08-05 13:39:21 +02:00
Benjamin Tissoires
34736aa96e HID: wacom: leds: handle the switch of the LEDs directly in the kernel
The EKR switches the LED directly, and there is no point in having
userspace handling the switch it self when it's easy enough to do
in the kernel.

The other benefit is that now userspace does not need to have root access
to the LED but need only to read them with user privileges.

Signed-off-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Acked-by: Ping Cheng <pingc@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2016-08-05 13:39:20 +02:00
Benjamin Tissoires
59d69bc821 HID: wacom: EKR: have one power_supply per remote
Previously, all the remotes attached to the same receiver would share the
same power_supply. That's not good as the remotes will constantly change
the battery information according to their own state.

To have something generic enough, we introduce struct wacom_battery
which regroups all the information we need for a battery.

Signed-off-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Acked-by: Ping Cheng <pingc@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2016-08-05 13:39:18 +02:00
Benjamin Tissoires
7c35dc3cd4 HID: wacom: EKR: allocate one input node per remote
Thanks to devres, we can now afford to create more than one input node
without having to overload the remove/failure paths. Having one input
node per remote is something which should have been implemented from start
but the probability of having users with several remotes is quite low.
Anyway, still, better looking at the future and implement things properly.

Remote input nodes will be freed/unregistered magically as they are
created in the devres group &remote->remotes[index].

We need to open the hid node now that the remotes are dynamically
allocated.

Signed-off-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Acked-by: Ping Cheng <pingc@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2016-08-05 13:39:18 +02:00
Benjamin Tissoires
e7749f6e5f HID: wacom: EKR: have one array of struct remotes instead of many arrays
No functional changes, just a prep patch for the one after.

Signed-off-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Acked-by: Ping Cheng <pingc@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2016-08-05 13:39:17 +02:00
Benjamin Tissoires
83e6b40e2d HID: wacom: EKR: have the wacom resources dynamically allocated
If we want to have one input device per remote, it's better to have our
own struct wacom_remote which is dynamically allocated.

Signed-off-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Acked-by: Ping Cheng <pingc@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2016-08-05 13:39:16 +02:00
Benjamin Tissoires
e6f2813a6d HID: wacom: EKR: add a worker to add/remove resources on addition/removal
wacom_remote_status_irq() sends information of addition/removal of EKR.
We want to allocate one input node per remote, so better having this
in a separate worker, not handled in the IRQ directly.

Signed-off-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Acked-by: Ping Cheng <pingc@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2016-08-05 13:39:16 +02:00
Benjamin Tissoires
a50aac7193 HID: wacom: leds: dynamically allocate LED groups
We need to add an action to ensure wacom->led.groups is null when
wacom_led_control() gets called after the resources has been freed.

This also prevents to send a LED command when there is no support
from the device.

Signed-off-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Acked-by: Ping Cheng <pingc@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2016-08-05 13:39:15 +02:00
Benjamin Tissoires
84dfbd7f2a HID: wacom: put the managed resources in a group
We currently have a complex clean_inputs() function while this can be
handled all by devres. Set a group that we can destroy in wireless_work().

Signed-off-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Acked-by: Ping Cheng <pingc@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2016-08-05 13:39:14 +02:00
Benjamin Tissoires
d17d1f1711 HID: wacom: use one work queue per task
Looks like the battery hijacked the wireless worker. That's not fair so
use a work queue per task.

Signed-off-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Acked-by: Ping Cheng <pingc@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2016-08-05 13:39:13 +02:00
Benjamin Tissoires
d453b87612 HID: wacom: actually report the battery level for wireless connected
Since fd5f92b ("HID: wacom: reuse wacom_parse_and_register() in
wireless_work"), wacom->shared->type is not set.
Send the information of the battery if we have one.

Signed-off-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Acked-by: Ping Cheng <pingc@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2016-08-05 13:39:11 +02:00
Jiri Kosina
66bc5ba523 Merge branch 'for-4.7/wacom' into for-linus 2016-05-17 12:42:27 +02:00
Ping Cheng
eff6ca9799 HID: wacom: add missed stylus_in_proximity line back
Commit 7e12978 ("HID: wacom: break out wacom_intuos_get_tool_type") by accident
removed stylus_in_proximity flag for Intuos series while shuffling the code
around.

Fix that by reintroducing that flag setting in wacom_intuos_inout(), where
it originally was.

Fixes: 7e12978 ("HID: wacom: break out wacom_intuos_get_tool_type")
Signed-off-by: Ping Cheng <pingc@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2016-05-03 12:03:44 +02:00
Jason Gerecke
bef7e20006 HID: wacom: Add fuzz factor to distance and tilt axes
The fuzz present on the distance and tilt axes is noticable when a puck is
present, and userspace (specifically libinput) would like the ability to
filter out the noise. To facilitate this, we assign a fuzz value of '1'
for the distance and tilt axes. This is large enough to cover most of the
natural variation in distance value as the puck is moved around, and
enough to cover the jitter in rotation (reported through tilt axes) when
the puck is left alone.

Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2016-05-03 11:55:05 +02:00
Ping Cheng
e1123fe975 HID: wacom: Add support for DTK-1651
DTK-1651 is a display pen-only tablet

Signed-off-by: Ping Cheng <pingc@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2016-04-12 23:23:53 +02:00
Benjamin Tissoires
580549ef6b HID: wacom: fix Bamboo ONE oops
Looks like recent changes in the Wacom driver made the Bamboo ONE crashes.
The tablet behaves as if it was a regular Bamboo device with pen, touch
and pad, but there is no physical pad connected to it.
The weird part is that the pad is still sending events and given that
there is no input node connected to it, we get  anull pointer exception.

Link: https://bugzilla.redhat.com/show_bug.cgi?id=1317116

Signed-off-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Acked-by: Ping Cheng <pingc@wacom.com>
Cc: stable@vger.kernel.org
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2016-03-29 15:42:27 +02:00
Benjamin Tissoires
7e129783b0 HID: wacom: break out wacom_intuos_get_tool_type
Allow to reuse the code in a later series and simplifies
the reading of wacom_intuos_inout().

Signed-off-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Acked-by: Ping Cheng <pingc@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2016-02-16 20:40:36 +01:00
Ping Cheng
526d6e7b57 HID: wacom - Add quirks for INTUOSHT2 in range events
INTUOSHT2 in range event is not used to indicate in proximity state.
INTUOSHT2 only has one stylus.

Signed-off-by: Ping Cheng <pingc@wacom.com>
Reviewed-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2016-01-18 23:02:57 +01:00
Ping Cheng
c1b03f5511 HID: wacom - Cleanup touch arbitration logic
stylus_in_proximity was introduced to support touch arbitration
before in range was supported. With in range event, the logic
changed. stylus_in_proximity should be set for both in prox and
in range events.

To finish a clean touch arbitration logic, we should send touch
up (if it was down) before posting any general pen events.

Signed-off-by: Ping Cheng <pingc@wacom.com>
Reviewed-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2016-01-18 23:02:56 +01:00
Ping Cheng
4750f5fe29 HID: wacom - make sure wacom_intuos_inout only process in/out events
Move general events related data validation to wacom_intuos_general.

Signed-off-by: Ping Cheng <pingc@wacom.com>
Reviewed-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2016-01-18 23:02:56 +01:00
Ping Cheng
599b082095 HID: wacom - request tool info only when we get general events
Move wacom_intuos_schedule_prox_event inside wacom_intuos_general
so we don't call it when general event data isn't ready.

Signed-off-by: Ping Cheng <pingc@wacom.com>
Reviewed-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2016-01-18 23:02:55 +01:00
Jiri Kosina
83f1bfd6f5 Merge branches 'for-4.4/upstream-fixes', 'for-4.5/async-suspend', 'for-4.5/container-of-cleanups', 'for-4.5/core', 'for-4.5/i2c-hid', 'for-4.5/logitech', 'for-4.5/multitouch', 'for-4.5/sony', 'for-4.5/upstream' and 'for-4.5/wacom' into for-linus 2016-01-14 16:11:06 +01:00
Jason Gerecke
0bbfe28ad0 HID: wacom: Use correct report to query pen ID from INTUOSHT2 devices
Unlike other tablets which are compatible with the wacom_intuos_irq handler,
INTUOSHT2 devices provide pen ID with report ID 8 instead of 5. To ensure
wacom_intuos_schedule_prox_event works as intended for these tablets, we
must be sure it uses the correct report ID in this case.

Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2016-01-08 10:15:22 +01:00
Jason Gerecke
0402b6b77a HID: wacom: Fix pad button range for CINTIQ_COMPANION_2
Commit c7f0522 incorrectly constructs the 'buttons' variable for the
CINTIQ_COMPANION_2 case. The high nybble of data[2] is shifted four
bits too far, leaving the bits associated with BTN_7 through BTN_A
unset.

Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2015-12-18 00:03:07 +01:00
Jason Gerecke
aaae03e4f7 HID: wacom: Fix touchring value reporting
Commit c7f0522 reports incorrect touchring values to userspace. This is
due to its incorrect handling of the 'touched' bit present in the 'ring1'
and 'ring2' variables. Instead of using this bit when determining if a
value should be sent, the ABS_WHEEL and ABS_INPUT check (different?!)
portions of the position bits. Furthermore, the full values of 'ring1'
and 'ring2' are reported to userspace, despite the 'touched' flag
needing to be trimmed beforehand. This commit addresses both issues.

Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2015-12-18 00:03:07 +01:00
Jason Gerecke
03a0dc546b HID: wacom: Report 'strip2' values in ABS_RY
Commit c7f0522 accidentally used ABS_RX for reporting both 'strip1' and
'strip2', when the latter should actually be reported through ABS_RY.

Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2015-12-18 00:03:06 +01:00
Jason Gerecke
f73d08d073 HID: wacom: Limit touchstrip data to 13 bits
Commit c7f0522 uses sixteen bits of data in the construction of 'strip1'
and 'strip2'. This can cause problems in some cases, however, since some
tablets store flags in the MSB of data[2] and data[4] that should not be
included in these values. This restores the 0x1f mask that used prior
to c7f0522.

Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2015-12-18 00:03:06 +01:00
Dan Carpenter
8f9cfdd359 HID: wacom: bitwise vs logical ORs
Smatch complains that these should probably be bitwise ORs instead of
logical.  It doesn't matter for "prox" but it makes a difference for
"strip1" and "strip2".

Fixes: c7f0522a1a ('HID: wacom: Slim down wacom_intuos_pad processing')
Signed-off-by: Dan Carpenter <dan.carpenter@oracle.com>
Reviewed-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2015-12-18 00:01:35 +01:00
Jason Gerecke
be853fd1c6 HID: wacom: Apply lowres quirk to BAMBOO_TOUCH devices
When splitting the touch-only "BAMBOO_TOUCH" type out of the existing
"BAMBOO_PT" type in 3b164a00, the lowres quirk was not updated so that
it would continue to apply to these devices (effectively only the 0xD0).
The absence of this quirk does not significantly impact usability, but
is a correctness issue nonetheless.

Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2015-12-08 15:12:00 +01:00
Jason Gerecke
061099936a HID: wacom: Rename wacom ID report ID macros
"INTUOSREAD" and "INTUOSWRITE" are poorly named. These are report IDs
for pen ID (proximity) packets. It should be noted that the latter is
only used on Intuos/Intuos2 for a second stylus when DualTrack is in use.

Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2015-12-02 21:44:52 +01:00
Jason Gerecke
5f33f430ef HID: wacom: Clean up value reading
Make the logic for reading X, Y, distance, and pressure a bit more
clear. An additional bit was stuffed into the packet format many
models back, and /most/ devices in use will use it. If we happen
to be dealing with a particularly old tablet, just shift it off
the end to pretend we never read it.

Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2015-12-02 21:44:52 +01:00
Jason Gerecke
571f572f9a HID: wacom: Further clean up wacom_intuos_general packet decoder
Continue re-organizing and trimming cases to make it easier to wrap
the brain around. A number of changes were made after consulting the
protocol spec and so don't necessarily follow from the code itself.

Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2015-12-02 21:44:51 +01:00
Jason Gerecke
a8a09c8597 HID: wacom: Replace magic masks and comparisons with switch cases
Reasoning through the conditions under which a particular block of code
in 'wacom_intuos_general' will be reached is not at all easy due to the
sheer number of magic masks and comparisons. Remove these and replace
them with a switch statement over the various 'types' of packets that
will be encountered.

Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2015-12-02 21:44:51 +01:00
Jason Gerecke
16e0a6a0d2 HID: wacom: Centralize Intuos pen packet decoding
Continue to slim down 'wacom_intuos_irq' by moving all decoding and
reporting of pen packet data into the  'wacom_intuos_general' function.

Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2015-12-02 21:44:51 +01:00
Jason Gerecke
c7f0522a1a HID: wacom: Slim down wacom_intuos_pad processing
Seperate the function into two halves: first gather data from the packet,
next report all gathered data. The input subsystem should automatically
mute any events that aren't actually declared for the tablet at hand.

Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2015-12-02 21:44:50 +01:00
Jason Gerecke
fb013a01d4 HID: wacom: Move Intuos pad handling code into dedicated function
Begin slimming down the body of 'wacom_intuos_irq' by moving out its
largest block of code to a dedicated 'wacom_intuos_pad' function.

Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2015-12-02 21:44:50 +01:00
Jiri Kosina
a3088abc68 HID: wacom: fixup quirks setup for WACOM_DEVICETYPE_PAD
Given that INTUOSHT < BAMBOO_PT

	features->type >= INTUOSHT || features->type <= BAMBOO_PT

condition is always true, and therefore device_type is under certain
circumstances wrongly set with WACOM_DEVICETYPE_PAD bit set.

Fix the condition so that it actually represents the range as intended.

Reported-by: David Binderman <dcb314@hotmail.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2015-11-17 00:24:14 +01:00
Ping Cheng
ff38e82931 HID: wacom: Add outbounding area for DTU1141
DTU1141 has an extra 1 mm tablet active outbounding area on each
side of the display, same as those recently released DTUs.

Signed-off-by: Ping Cheng <pingc@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2015-11-13 11:12:40 +01:00
Jiri Kosina
d64e19db03 Merge branches 'for-4.3/upstream-fixes', 'for-4.4/corsair', 'for-4.4/dragonrise', 'for-4.4/i2c-hid', 'for-4.4/logitech', 'for-4.4/microsoft', 'for-4.4/multitouch', 'for-4.4/roccat-sysfs-deprecation', 'for-4.4/upstream' and 'for-4.4/wacom' into for-linus 2015-11-06 21:45:15 +01:00
Jason Gerecke
8253d42be8 HID: wacom: Fix ABS_MISC reporting for Cintiq Companion 2
The pad handling code introduced for the Cintiq Companion 2 (f7acb55)
looks at the wrong bytes in the report when deciding whether ABS_MISC
should be sent. This does not cause any issues with the X driver now
that the pen and pad have been split to separate devices, but is
incorrect and has caused issues when backporting to distros with pre-
3.17 kernels.

Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Reviewed-by: Ping Cheng <pingc@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2015-11-03 14:36:23 +01:00
Ping Cheng
7adb91bd78 HID: wacom: fix Intuos wireless report id issue
Intuos Pen in wireless mode does not have the same report id (2) as
when it is in USB mode (17).

This patch also moves WIRELESS next to REMOTE in type enum so we
can group devices with similar features easily.

Reported-by: Dale Brewe <dlbrewe@hotmail.com>
Tested-by: Dale Brewe <dlbrewe@hotmail.com>
Signed-off-by: Ping Cheng <pingc@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2015-11-02 17:38:23 +01:00
Jason Gerecke
df70793805 HID: wacom: Expect 'touch_max' touches if HID_DG_CONTACTCOUNT not present
When introduced in commit 1b5d514, the check 'if (hid_data->cc_index >= 0)'
in 'wacom_wac_finger_pre_report' was intended to switch where the driver
got the expected number of contacts from: HID_DG_CONTACTCOUNT if the usage
was present, or 'touch_max' otherwise. Unfortunately, an oversight worthy
of a brown paper bag (specifically, that 'cc_index' could never be negative)
meant that the latter 'else' clause would never be entered.

The patch prior to this one introduced a way for 'cc_index' to be negative,
but only if HID_DG_CONTACTCOUNT is present in some report _other_ than the
one being processed. To ensure the 'else' clause is also entered for devices
which don't have HID_DG_CONTACTCOUNT on _any_ report, we add the additional
constraint that 'cc_report' be non-zero (which is true only if the usage is
present in some report).

Cc: stable@vger.kernel.org
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2015-10-21 13:13:12 +02:00
Jason Gerecke
499522c8c0 HID: wacom: Tie cached HID_DG_CONTACTCOUNT indices to report ID
The cached indicies 'cc_index' and 'cc_value_index' introduced in 1b5d514
are only valid for a single report ID. If a touchscreen has multiple
reports with a HID_DG_CONTACTCOUNT usage, its possible that the values
will not be correct for the report we're handling, resulting in an
incorrect value for 'num_expected'. This has been observed with the Cintiq
Companion 2.

To address this, we store the ID of the report those indicies are valid
for in a new  'cc_report' variable. Before using them to get the expected
contact count, we first check if the ID of the report we're processing
matches 'cc_report'. If it doesn't, we update the indicies to point to
the HID_DG_CONTACTCOUNT usage of the current report (if it has one).

Cc: stable@vger.kernel.org
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2015-10-21 13:13:11 +02:00
Jason Gerecke
8d515fda89 HID: wacom: Report full pressure range for Intuos, Cintiq 13HD Touch
The new Intuos tablets added in eda01da and the Cintiq 13HD Touch added
in b4bf212 are capable of reporting 2048 levels of pressure. Although the
kernel reports the correct range to userspace, an oversight has resulted
in the driver ingoring the 11th pressure bit and only sending pressures
of 0 through 1023.

We could fix this issue by expanding the type check to include these
devices, but it makes much more sense to just have the driver look at
the device's maximum pressure when determining if it should read the
11th bit.

Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Reviewed-by: Ping Cheng <pingc@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2015-10-21 11:18:41 +02:00