Seperate the function into two halves: first gather data from the packet,
next report all gathered data. The input subsystem should automatically
mute any events that aren't actually declared for the tablet at hand.
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Begin slimming down the body of 'wacom_intuos_irq' by moving out its
largest block of code to a dedicated 'wacom_intuos_pad' function.
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
The pad handling code introduced for the Cintiq Companion 2 (f7acb55)
looks at the wrong bytes in the report when deciding whether ABS_MISC
should be sent. This does not cause any issues with the X driver now
that the pen and pad have been split to separate devices, but is
incorrect and has caused issues when backporting to distros with pre-
3.17 kernels.
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Reviewed-by: Ping Cheng <pingc@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Intuos Pen in wireless mode does not have the same report id (2) as
when it is in USB mode (17).
This patch also moves WIRELESS next to REMOTE in type enum so we
can group devices with similar features easily.
Reported-by: Dale Brewe <dlbrewe@hotmail.com>
Tested-by: Dale Brewe <dlbrewe@hotmail.com>
Signed-off-by: Ping Cheng <pingc@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
When introduced in commit 1b5d514, the check 'if (hid_data->cc_index >= 0)'
in 'wacom_wac_finger_pre_report' was intended to switch where the driver
got the expected number of contacts from: HID_DG_CONTACTCOUNT if the usage
was present, or 'touch_max' otherwise. Unfortunately, an oversight worthy
of a brown paper bag (specifically, that 'cc_index' could never be negative)
meant that the latter 'else' clause would never be entered.
The patch prior to this one introduced a way for 'cc_index' to be negative,
but only if HID_DG_CONTACTCOUNT is present in some report _other_ than the
one being processed. To ensure the 'else' clause is also entered for devices
which don't have HID_DG_CONTACTCOUNT on _any_ report, we add the additional
constraint that 'cc_report' be non-zero (which is true only if the usage is
present in some report).
Cc: stable@vger.kernel.org
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
The cached indicies 'cc_index' and 'cc_value_index' introduced in 1b5d514
are only valid for a single report ID. If a touchscreen has multiple
reports with a HID_DG_CONTACTCOUNT usage, its possible that the values
will not be correct for the report we're handling, resulting in an
incorrect value for 'num_expected'. This has been observed with the Cintiq
Companion 2.
To address this, we store the ID of the report those indicies are valid
for in a new 'cc_report' variable. Before using them to get the expected
contact count, we first check if the ID of the report we're processing
matches 'cc_report'. If it doesn't, we update the indicies to point to
the HID_DG_CONTACTCOUNT usage of the current report (if it has one).
Cc: stable@vger.kernel.org
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
The new Intuos tablets added in eda01da and the Cintiq 13HD Touch added
in b4bf212 are capable of reporting 2048 levels of pressure. Although the
kernel reports the correct range to userspace, an oversight has resulted
in the driver ingoring the 11th pressure bit and only sending pressures
of 0 through 1023.
We could fix this issue by expanding the type check to include these
devices, but it makes much more sense to just have the driver look at
the device's maximum pressure when determining if it should read the
11th bit.
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Reviewed-by: Ping Cheng <pingc@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Adds support for the EMR (pen+pad) and touchscreen devices used by the
Wacom Cintiq Companion 2. This applies both to using the device as a
standalone system, as well as when operating in "Cintiq mode" (where
the EMR/touchscreen are simply exposed as USB devices to the system
its connected to).
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Clifford Jolly <expiredpopsicle@gmail.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
This series of devices supports both pen and touch. It reports
touch data in Bamboo3 format and pen data in Intuos pro format.
Signed-off-by: Ping Cheng <pingc@wacom.com>
Tested-By: Aaron Skomra <aaron.skomra@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Not all Bamboo support both pen and touch. Make sure we deal with
pen only and touch only devices properly.
Signed-off-by: Ping Cheng <pingc@wacom.com>
Tested-By: Aaron Skomra <aaron.skomra@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
This device is pad (buttons) only, there is no stylus or touch. Up to
five remotes can pair with the device's associated USB dongle.
Signed-off-by: Aaron Skomra <aaron.skomra@wacom.com>
Reviewed-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Prior to this commit, numbered button bit setting was done separately
for each device type in wacom_setup_pad_capabilities(). Here we add a
numbered_buttons property to the wacom_features struct and extract the
repeated bit setting code to a new function:
wacom_settup_numbered_buttons().
Signed-off-by: Aaron Skomra <aaron.skomra@wacom.com>
Reviewed-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
The current generation of "Intuos" tablets (i.e. INTUOSHT) report touch
width and height data just like the "Intuos Pro" do. This commit changes
the code to allow these tablets to use the appropriate codepath instead
of the one intended for Intuos5/Bamboo.
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Unlike other IRQ functions, 'wacom_pl_irq' uses the second element of
the 'tool' array to store information about its single pen. This makes
the function more difficult to understand (since it doesn't follow the
general pattern of other IRQ functions) and prevents the possibility of
refactoring how pen state is stored.
This patch rewrites 'wacom_pl_irq' to follow the usual IRQ conventions,
including storing tool type in 'tool[0]' and implicitly tracking prox
with the 'id[0]' variable.
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
WACOM_QUIRK_NO_INPUT is a signal to the driver that input devices
should not be created for a particular device. This quirk was used by
the wireless receiver to prevent any devices from being created during
the initial probe (defering it instead until we got a tablet connection
event in 'wacom_wireless_work').
This quirk is not necessary now that a device_type is associated with each
device. Any input device allocated by 'wacom_allocate_inputs' which is
not necessary for a particular device is freed in 'wacom_register_inputs'.
In particular, none of the wireless receivers devices have the pen, pad,
or touch device types set so the same effect is achieved without the need
to be explicit.
We now return early in wacom_retrieve_hid_descriptor for wireless devices
(to prevent the device_type from being overridden) but since we ignore the
HID descriptor for the wireless reciever anyway, this is not an issue.
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Reviewed-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Signed-off-by: Jiri Kosina <jkosina@suse.com>
The monitor interface on the wireless receiver is more logically expressed
as a type of device instead of a quirk.
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Reviewed-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Signed-off-by: Jiri Kosina <jkosina@suse.com>
The HID_DG_WIDTH and HID_DG_HEIGHT usages report with width and height of
contacts. From this information, a crude determination of orientation is
also possible. This patch reports all three to userspace if a device
reports this usage.
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.com>
The reports sent from some touch devices (e.g. the Cintiq 24HDT) contain
junk data in the contact slots which follow the final "valid" contact.
To avoid forwarding it to usrspace, we store the reported contact count
during the pre-process phase and then only process that many contacts.
If a device sends its contacts across multiple reports (what Microsoft
refers to as "hybrid" mode) then the contact count will be zero for
reports other than the first.
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.com>
In some cases, we need access to information before it becomes available
to the 'event' handler. In particular, for some devices we cannot properly
process the finger data without first knowing the "contact count" at the
very end of the report (e.g. the Cintiq 24HDT touch screen, when forced
through the GENERIC codepath).
Since the HID subsystem doesn't provide a way to take action before 'event'
is called, we take a cue from hid-multitouch.c and add a pre-process step
within the 'report' handler that performs the same function.
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.com>
As mentioned in the comment in the code, both the pen and touch data
come from the interface tagged as BAMBOO_PAD. The driver re-routes the
events for the Pen to the generic HID interface and keeps the ones for
the touch through this current interface.
Clearing the WACOM_DEVICETYPE_PEN bit removes the extra unused interface
added in 2a6cdbd ("HID: wacom: Introduce new 'touch_input' device") and
makes the Bamboo PAD to behave like in 4.1.
Reviewed-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Signed-off-by: Jiri Kosina <jkosina@suse.com>
Commit 862cf55 ("HID: wacom: Introduce a new WACOM_DEVICETYPE_PAD device_type")
neglected to set the WACOM_DEVICETYPE_PAD flag for older two-finger Bamboo
Touch tablets. Not only does this result in the pad device not appearing when
such a tablet is plugged in, but also causes a segfault when 'wacom_bpt_touch'
tries to send pad events. This patch adds the flag to resolve these issues.
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.com>
Instead of having a single 'input_dev' device that will take either pen
or touch data depending on the type of the device, create seperate devices
devices for each. By splitting things like this, we can support devices
(e.g. the I2C "AES" sensors in some newer tablet PCs) that send both pen
and touch reports from a single endpoint.
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
This splits the 'wacom_setup_pentouch_input_capabilites' function into
pieces dedicated to doing setup for just the pen interface and just
the touch interface. This makes it easier to focus on the relevant
piece when making changes.
This patch introduces no functional changes.
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Historically, both the touch and pad tools would have shared the
'BTN_TOOL_FINGER' type. Any time you needed to distinguish the two, you
had to use some other bit of knowledge (e.g. that the pad was on the same
interface as the pen, and thus 'touch_max' would be zero).
To make these checks more readable, we introduce WACOM_DEVICETYPE_PAD.
Although we still have to rely on other bits of knowledge to set this
bit on the right interface (since it cannot be detected from the HID
descriptor), it can be done just once inside 'wacom_setup_device_quirks'.
This patch introduces no functional changes.
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
The USB devices that this driver has historically supported segregate the
pen and touch portions of the tablet. Oftentimes the segregation would be
done at the interface level, though on occasion (e.g. Cintiq 24HDT) the
tablet would combine two totally independent USB devices behind an internal
USB hub. Because pen and touch never shared the same interface, it made
sense for the 'device_type' to store a single value: "pen" or "touch".
Recently, however, some I2C devices have been created which combine the
two. A first step to accomodating this is to expand 'device_type' so that
it can represent two (or potentially more) types simultaneously. To do
this, we treat it as a bitfield and set/check individual bits rather
than using the '=' and '==' operators.
This should not result in any functional change since no supported devices
(that I'm aware of, at least) have HID descriptors that indicate both
pen and touch reports on a single interface.
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
We assumed all touch interfaces report touch data. But, Bamboo
and Intuos non-touch devices report express keys on touch
interface. We need to check touch_max before counting touches.
Reported-by: Tasos Sahanidis <tasos@tasossah.com>
Signed-off-by: Ping Cheng <pingc@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Currently, we assume a device_type of BTN_TOOL_PEN before scanning the
HID descriptor and then change the device_type if what we discover
proves that assumption wrong. This way of doing things makes it more
difficult to figure out if a device (particularly a HID_GENERIC device)
actually does tablet/touch input or is something completley different.
This patch leaves device_type at its initial value of 0 and then calls
'wacom_parse_hid' for every device (not just those that have touch).
As we map the usages, we can set the device_type as before. After we're
finished, we can then check if the value is still zero and do whatever
is most appropriate.
Detecting the pen can be a little tricky on most Wacom devices because
the descriptors describe opaque blobs. Fortunately, older Wacom tablets
have the HID_DG_DIGITIZER usage on the pen's application collection and
newer tablets seem to have a similar vendor-defined usage that we can
trigger on.
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Reviewed-by: Ping Cheng <pingc@wacom.com>
Reviewed-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
To determine if a touch is present in the single-touch case, we can
simply check if the BTN_TOUCH key is active or not. This will work for
both HID_GENERIC and other device types.
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
It makes probe routine easy to follow.
Signed-off-by: Ping Cheng <pingc@wacom.com>
Reviewed-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Pull HID updates from Jiri Kosina:
- quite a few firmware fixes for RMI driver by Andrew Duggan
- huion and uclogic drivers have been substantially overlaping in
functionality laterly. This redundancy is fixed by hid-huion driver
being merged into hid-uclogic; work done by Benjamin Tissoires and
Nikolai Kondrashov
- i2c-hid now supports ACPI GPIO interrupts; patch from Mika Westerberg
- Some of the quirks, that got separated into individual drivers, have
historically had EXPERT dependency. As HID subsystem matured (as
well as the individual drivers), this made less and less sense. This
dependency is now being removed by patch from Jean Delvare
- Logitech lg4ff driver received a couple of improvements for mode
switching, by Michal Malý
- multitouch driver now supports clickpads, patches by Benjamin
Tissoires and Seth Forshee
- hid-sensor framework received a substantial update; namely support
for Custom and Generic pages is being added; work done by Srinivas
Pandruvada
- wacom driver received substantial update; it now supports
i2c-conntected devices (Mika Westerberg), Bamboo PADs are now
properly supported (Benjamin Tissoires), much improved battery
reporting (Jason Gerecke) and pen proximity cleanups (Ping Cheng)
- small assorted fixes and device ID additions
* 'for-linus' of git://git.kernel.org/pub/scm/linux/kernel/git/jikos/hid: (68 commits)
HID: sensor: Update document for custom sensor
HID: sensor: Custom and Generic sensor support
HID: debug: fix error handling in hid_debug_events_read()
Input - mt: Fix input_mt_get_slot_by_key
HID: logitech-hidpp: fix error return code
HID: wacom: Add support for Cintiq 13HD Touch
HID: logitech-hidpp: add a module parameter to keep firmware gestures
HID: usbhid: yet another mouse with ALWAYS_POLL
HID: usbhid: more mice with ALWAYS_POLL
HID: wacom: set stylus_in_proximity before checking touch_down
HID: wacom: use wacom_wac_finger_count_touches to set touch_down
HID: wacom: remove hardcoded WACOM_QUIRK_MULTI_INPUT
HID: pidff: effect can't be NULL
HID: add quirk for PIXART OEM mouse used by HP
HID: add HP OEM mouse to quirk ALWAYS_POLL
HID: wacom: ask for a in-prox report when it was missed
HID: hid-sensor-hub: Fix sparse warning
HID: hid-sensor-hub: fix attribute read for logical usage id
HID: plantronics: fix Kconfig default
HID: pidff: support more than one concurrent effect
...
Cintiq 13HD Touch is a new display tablet with pen and 10 finger touches.
Signed-off-by: Ping Cheng <pingc@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
In wacom_bpt_pen, we checked touch_down before assigning new
stylus_in_proximity value. This would cause stylus_in_proximity not updated
properly if touch is down before pen is in proximity.
[jkosina@suse.cz: fix if-else style]
Signed-off-by: Ping Cheng <pingc@wacom.com>
Reviewed-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Counting number of touching fingers by wacom_wac_finger_count_touches so we
don't have to count them inside individual routines.
Signed-off-by: Ping Cheng <pingc@wacom.com>
Reviewed-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
The quirk was added for devices that support both pen and touch. It decides if
a device supports multiple inputs by hardcoded feature type. However, for some
devices, we do not know if they support both before accessing their HID
descriptors.
This patch relies on dynamically assigned device_type to make the decision.
Also, we make it certain that wacom_wac->shared is always created. That is, the
driver will not be loaded if it fails to create wacom_wac->shared.
Signed-off-by: Ping Cheng <pingc@wacom.com>
Reviewed-by: Jason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Conflicts:
drivers/hid/wacom_wac.c
Need to fetch the 4.0 fixes to apply 4.1 patches based on top
of those.
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
486b908 (HID: wacom: do not send pen events before touch is up/forced out)
introduces a kernel oops when plugging a tablet without touch.
wacom->shared is null for these devices so this leads to a null pointer
exception.
Change the condition to make it clear that what we need is wacom->shared
not NULL.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
If noone listens to the input device when a tool comes in proximity,
the tablet does not send the in-prox event when a client becomes available.
That means that no events will be sent until the tool is taken out of
proximity.
In this situation, ask for the report WACOM_REPORT_INTUOSREAD which will
read the corresponding feature and generate an in-prox event.
To make some generation of hardware working, we need to unset the
quirk NO_GET set by hid-core because the interfaces are seen as "boot
mouse".
We don't schedule this read in a worker while we are in an IO interrupt.
We know that usbhid will do it asynchronously. If this is triggered by
uhid, then this is obviously a client side bug :)
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Acked-by: Jason Gerecke <killertofu@gmail.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Declare the POWER_SUPPLY_PROP_PRESENT property to provide userspace
with a way to determine if the battery on a wireless tablet is plugged
in. Although current wireless tablets do not explicitly report this
information, it can be inferred from other state information. In
particular, a battery is assumed to be present if any of the following
are true: a non-zero battery level reported, the battery is reported as
charging, or the tablet is operating wirelessly.
Note: The last condition above may not strictly hold for the Graphire
Wireless (it charges from a DC barrel jack instead of a USB port), but I
do not know what is reported in the no-battery condition.
Signed-off-by: Jason Gerecke <killertofu@gmail.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
The status packet for tablets which can use a wireless module contains a
bit that is set if the battery is charging. This bit will be 0 if either
a battery is not present or if the battery has reached full charge. Note
that the charging circuit may continue to charge the battery for a short
time after reaching "100%".
Signed-off-by: Jason Gerecke <killertofu@gmail.com>
Acked-by: Ping Cheng <pingc@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Calls the wacom_status_irq function to report battery status for the
Intuos Pro and Intuos5 (in addition to the already-reporting Intuos
and last-generation Bamboo).
Signed-off-by: Jason Gerecke <killertofu@gmail.com>
Acked-by: Ping Cheng <pingc@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
If a wireless adapter (which contains the charging circuitry) is
detected as being attached to the tablet then create a new battery
interface and update its status as data is reported. Also destroy the
battery if the adapter goes away.
Signed-off-by: Jason Gerecke <killertofu@gmail.com>
Acked-by: Ping Cheng <pingc@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Has the 'wacom_notify_battery' function take on the job of detecting if
updating the power supply is necessary to remove multiple
nearly-identical 'if' blocks.
Signed-off-by: Jason Gerecke <killertofu@gmail.com>
Acked-by: Ping Cheng <pingc@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
In addition to the touchswitch state for "Intuos", these packets are
also sent by the Intuos Pro, Intuos5, and last-generation Bamboo
tablets when using a wired connection. They contain, among other
things, information about the optional wireless module and battery
charge state (to be supported in subsuquent patches).
Signed-off-by: Jason Gerecke <killertofu@gmail.com>
Acked-by: Ping Cheng <pingc@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
touch_down is a flag to indicate if there are touches on tablet
or not. Since one set of touch events may be posted over more
than one data packet/touch frame, and pen may come in proximity
while touch events are partially sent, counting all touch events
for the set reflects the actual status of touch_down.
Signed-off-by: Ping Cheng <pingc@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
If pen comes in proximity while touch is down, we force touch up
before sending pen events. Otherwise, there can be unfinished
touch events compete with pen events. This idea has been fully
implemented for Tablet PCs. But other tablets that support both
pen and touch are not fully considered.
Signed-off-by: Ping Cheng <pingc@wacom.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>