The check for old hardware versions that did not have SMCDv2 support was
using suspicious pointer magic. Address the fields using an array.
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
When building a CLC proposal message then the list of ISM devices does
not need to contain multiple devices that have the same chid value,
all these devices use the same function at the end.
Improve smc_find_ism_v2_device_clnt() to collect only ISM devices that
have unique chid values.
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This patch covers the small SMCD version 2 changes for CLC decline.
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
SMC Version 2 defines a first contact extension for CLC accept
and CLC confirm. This patch covers sending and receiving of the
CLC first contact extension.
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The new format of SMCD V2 CLC accept and confirm is introduced,
and building and checking of SMCD V2 CLC accepts / confirms is adapted
accordingly.
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
SMCD Version 2 allows to propose up to 8 additional ISM devices
offered to the peer as candidates for SMCD communication.
This patch covers the server side, i.e. selection of an ISM device
matching one of the proposed ISM devices, that will be used for
CLC accept
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The new format of an SMCD V2 CLC proposal is introduced, and
building and checking of SMCD V2 CLC proposals is adapted
accordingly.
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
SMCD Version 2 allows to propose up to 8 additional ISM devices
offered to the peer as candidates for SMCD communication.
This patch covers determination of the ISM devices to be proposed.
ISM devices without PNETID are preferred, since ISM devices with
PNETID are a V1 leftover and will disappear over the time.
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
SMCD version 2 allows usage of ISM devices with hardware PNETID
only, if an Ethernet net_device exists with the same hardware PNETID.
This requires to maintain a list of pnetids belonging to
Ethernet net_devices, which is covered by this patch.
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
With SMCD version 2 the CHIDs of ISM devices are needed for the
CLC handshake.
This patch provides the new callback to retrieve the CHID of an
ISM device.
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
SMCD version 2 defines a System Enterprise ID (short SEID).
This patch contains the SEID creation and adds the callback to
retrieve the created SEID.
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
SMCD Version 2 allows proposing of up to 8 ISM devices in addition
to the native ISM device of SMCD Version 1.
This patch prepares the struct smc_init_info to deal with these
additional 8 ISM devices.
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
When sending CLC confirm and CLC accept, separate the trailing
part of the message from the initial part (to be prepared for
future first contact extension).
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This patch provides better separation of device determinations
in function smc_listen_work(). No functional change.
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
SMCD version 2 defines 2 more bits in the CLC header to specify
version 2 types. This patch prepares better naming of the CLC
header fields. No functional change.
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Use the existing symbol _S instead of SMC_ASCII_BLANK, and introduce a
helper to check if a pnetid is set. No functional change.
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
If smc_listen_rmda_finish() returns with an error, the storage
addressed by 'buf' is freed a second time.
Consolidate freeing under a common label and jump to that label.
Fixes: 6bb14e48ee ("net/smc: dynamic allocation of CLC proposal buffer")
Reported-by: Dan Carpenter <dan.carpenter@oracle.com>
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
smc->clcsock and smc->clcsock->sk are used before the check if they can
be dereferenced. Fix this by checking the variables first.
Fixes: a60a2b1e0a ("net/smc: reduce active tcp_listen workers")
Reported-by: kernel test robot <lkp@intel.com>
Reported-by: Dan Carpenter <dan.carpenter@oracle.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
There are 6 types of workers which exist per smc connection. 3 of them
are used for listen and handshake processing, another 2 are used for
close and abort processing and 1 is the tx worker that moves calls to
sleeping functions into a worker.
To prevent flooding of the system work queue when many connections are
opened or closed at the same time (some pattern uperf implements), move
those workers to one of 3 smc-specific work queues. Two work queues are
module-global and used for handshake and close workers. The third work
queue is defined per link group and used by the tx workers that may
sleep waiting for resources of this link group.
And in smc_llc_enqueue() queue the llc_event_work work to the system
prio work queue because its critical that this work is started fast.
Reviewed-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
When the netlink messages to be sent to the userspace
are too big for a single netlink message, send them in
chunks using the netlink_dump infrastructure. Modify the
smc diag dump code so that it can signal to the netlink_dump
infrastructure that it needs to send more data.
Signed-off-by: Guvenc Gulce <guvenc@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
smc_lgr_cleanup_early() schedules the free worker with delay. DMB
unregistering occurs in this delayed worker increasing the risk
to reach the SMCD SBA limit without need. Terminate the
linkgroup immediately, since termination means early DMB unregistering.
For SMCD the global smc_server_lgr_pending lock is given up early.
A linkgroup to be given up with smc_lgr_cleanup_early() may already
contain more than one connection. Using __smc_lgr_terminate() in
smc_lgr_cleanup_early() covers this.
And consolidate smc_ism_put_vlan() and smc_put_device() into smc_lgr_free()
only.
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
smc_listen_work() contains already an smc_listen_decline() exit.
Use this exit for smc_listen_rdma_finish() problems as well.
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Move check whether peer can be reached into smc_pnet_find_ism_by_pnetid().
Thus searching continues for another ism device, if check fails.
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
smc_clc_send_accept() and smc_clc_send_confirm() are quite similar.
Move common code into a separate function smc_clc_send_confirm_accept().
And introduce separate SMCD and SMCR struct definitions for CLC accept
resp. confirm.
No functional change.
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Reduce stack size for smc_listen_work() and smc_clc_send_proposal()
by dynamic allocation of the CLC buffer to be received or sent.
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Field names "srv_first_contact" and "cln_first_contact" are misleading,
since they apply to both, server and client. Rename them to
"first_contact_peer" and "first_contact_local".
Rename "ism_gid" by the more precise name "ism_peer_gid".
Rename version constant "SMC_CLC_V1" into "SMC_V1".
No functional change.
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
SMC starts a separate tcp_listen worker for every SMC socket in
state SMC_LISTEN, and can accept an incoming connection request only,
if this worker is really running and waiting in kernel_accept(). But
the number of running workers is limited.
This patch reworks the listening SMC code and starts a tcp_listen worker
after the SYN-ACK handshake on the internal clc-socket only.
Suggested-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Reviewed-by: Guvenc Gulce <guvenc@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Pull networking fixes from David Miller:
1) Use netif_rx_ni() when necessary in batman-adv stack, from Jussi
Kivilinna.
2) Fix loss of RTT samples in rxrpc, from David Howells.
3) Memory leak in hns_nic_dev_probe(), from Dignhao Liu.
4) ravb module cannot be unloaded, fix from Yuusuke Ashizuka.
5) We disable BH for too lokng in sctp_get_port_local(), add a
cond_resched() here as well, from Xin Long.
6) Fix memory leak in st95hf_in_send_cmd, from Dinghao Liu.
7) Out of bound access in bpf_raw_tp_link_fill_link_info(), from
Yonghong Song.
8) Missing of_node_put() in mt7530 DSA driver, from Sumera
Priyadarsini.
9) Fix crash in bnxt_fw_reset_task(), from Michael Chan.
10) Fix geneve tunnel checksumming bug in hns3, from Yi Li.
11) Memory leak in rxkad_verify_response, from Dinghao Liu.
12) In tipc, don't use smp_processor_id() in preemptible context. From
Tuong Lien.
13) Fix signedness issue in mlx4 memory allocation, from Shung-Hsi Yu.
14) Missing clk_disable_prepare() in gemini driver, from Dan Carpenter.
15) Fix ABI mismatch between driver and firmware in nfp, from Louis
Peens.
* git://git.kernel.org/pub/scm/linux/kernel/git/netdev/net: (110 commits)
net/smc: fix sock refcounting in case of termination
net/smc: reset sndbuf_desc if freed
net/smc: set rx_off for SMCR explicitly
net/smc: fix toleration of fake add_link messages
tg3: Fix soft lockup when tg3_reset_task() fails.
doc: net: dsa: Fix typo in config code sample
net: dp83867: Fix WoL SecureOn password
nfp: flower: fix ABI mismatch between driver and firmware
tipc: fix shutdown() of connectionless socket
ipv6: Fix sysctl max for fib_multipath_hash_policy
drivers/net/wan/hdlc: Change the default of hard_header_len to 0
net: gemini: Fix another missing clk_disable_unprepare() in probe
net: bcmgenet: fix mask check in bcmgenet_validate_flow()
amd-xgbe: Add support for new port mode
net: usb: dm9601: Add USB ID of Keenetic Plus DSL
vhost: fix typo in error message
net: ethernet: mlx4: Fix memory allocation in mlx4_buddy_init()
pktgen: fix error message with wrong function name
net: ethernet: ti: am65-cpsw: fix rmii 100Mbit link mode
cxgb4: fix thermal zone device registration
...
When an ISM device is removed, all its linkgroups are terminated,
i.e. all the corresponding connections are killed.
Connection killing invokes smc_close_active_abort(), which decreases
the sock refcount for certain states to simulate passive closing.
And it cancels the close worker and has to give up the sock lock for
this timeframe. This opens the door for a passive close worker or a
socket close to run in between. In this case smc_close_active_abort() and
passive close worker resp. smc_release() might do a sock_put for passive
closing. This causes:
[ 1323.315943] refcount_t: underflow; use-after-free.
[ 1323.316055] WARNING: CPU: 3 PID: 54469 at lib/refcount.c:28 refcount_warn_saturate+0xe8/0x130
[ 1323.316069] Kernel panic - not syncing: panic_on_warn set ...
[ 1323.316084] CPU: 3 PID: 54469 Comm: uperf Not tainted 5.9.0-20200826.rc2.git0.46328853ed20.300.fc32.s390x+debug #1
[ 1323.316096] Hardware name: IBM 2964 NC9 702 (z/VM 6.4.0)
[ 1323.316108] Call Trace:
[ 1323.316125] [<00000000c0d4aae8>] show_stack+0x90/0xf8
[ 1323.316143] [<00000000c15989b0>] dump_stack+0xa8/0xe8
[ 1323.316158] [<00000000c0d8344e>] panic+0x11e/0x288
[ 1323.316173] [<00000000c0d83144>] __warn+0xac/0x158
[ 1323.316187] [<00000000c1597a7a>] report_bug+0xb2/0x130
[ 1323.316201] [<00000000c0d36424>] monitor_event_exception+0x44/0xc0
[ 1323.316219] [<00000000c195c716>] pgm_check_handler+0x1da/0x238
[ 1323.316234] [<00000000c151844c>] refcount_warn_saturate+0xec/0x130
[ 1323.316280] ([<00000000c1518448>] refcount_warn_saturate+0xe8/0x130)
[ 1323.316310] [<000003ff801f2e2a>] smc_release+0x192/0x1c8 [smc]
[ 1323.316323] [<00000000c169f1fa>] __sock_release+0x5a/0xe0
[ 1323.316334] [<00000000c169f2ac>] sock_close+0x2c/0x40
[ 1323.316350] [<00000000c1086de0>] __fput+0xb8/0x278
[ 1323.316362] [<00000000c0db1e0e>] task_work_run+0x76/0xb8
[ 1323.316393] [<00000000c0d8ab84>] do_exit+0x26c/0x520
[ 1323.316408] [<00000000c0d8af08>] do_group_exit+0x48/0xc0
[ 1323.316421] [<00000000c0d8afa8>] __s390x_sys_exit_group+0x28/0x38
[ 1323.316433] [<00000000c195c32c>] system_call+0xe0/0x2b4
[ 1323.316446] 1 lock held by uperf/54469:
[ 1323.316456] #0: 0000000044125e60 (&sb->s_type->i_mutex_key#9){+.+.}-{3:3}, at: __sock_release+0x44/0xe0
The patch rechecks sock state in smc_close_active_abort() after
smc_close_cancel_work() to avoid duplicate decrease of sock
refcount for the same purpose.
Fixes: 611b63a127 ("net/smc: cancel tx worker in case of socket aborts")
Reviewed-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
SMC tries to make use of SMCD first. If a problem shows up,
it tries to switch to SMCR. If the SMCD initializing problem shows
up after the SMCD connection has already been initialized, field
rx_off keeps the wrong SMCD value for SMCR, which results in corrupted
data at the receiver.
This patch adds an explicit (re-)setting of field rx_off to zero if the
connection uses SMCR.
Fixes: be244f28d2 ("net/smc: add SMC-D support in data transfer")
Reviewed-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Older SMCR implementations had no link failover support and used one
link only. Because the handshake protocol requires to try the
establishment of a second link the old code sent a fake add_link message
and declined any server response afterwards.
The current code supports multiple links and inspects the received fake
add_link message more closely. To tolerate the fake add_link messages
smc_llc_is_local_add_link() needs an improved check of the message to
be able to separate between locally enqueued and fake add_link messages.
And smc_llc_cli_add_link() needs to check if the provided qp_mtu size is
invalid and reject the add_link request in that case.
Fixes: c48254fa48 ("net/smc: move add link processing for new device into llc layer")
Reviewed-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
__smc_diag_dump() is potentially copying uninitialized kernel stack memory
into socket buffers, since the compiler may leave a 4-byte hole near the
beginning of `struct smcd_diag_dmbinfo`. Fix it by initializing `dinfo`
with memset().
Fixes: 4b1b7d3b30 ("net/smc: add SMC-D diag support")
Suggested-by: Dan Carpenter <dan.carpenter@oracle.com>
Signed-off-by: Peilin Ye <yepeilin.cs@gmail.com>
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
When the maximum dmb buffer limit for an ism device is reached no more
dmb buffers can be registered. When this happens the reason code is set
to SMC_CLC_DECL_MEM indicating out-of-memory. This is the same reason
code that is used when no memory could be allocated for the new dmb
buffer.
This is confusing for users when they see this error but there is more
memory available. To solve this set a separate new reason code when the
maximum dmb limit exceeded.
Reviewed-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The UDP reuseport conflict was a little bit tricky.
The net-next code, via bpf-next, extracted the reuseport handling
into a helper so that the BPF sk lookup code could invoke it.
At the same time, the logic for reuseport handling of unconnected
sockets changed via commit efc6b6f6c3
which changed the logic to carry on the reuseport result into the
rest of the lookup loop if we do not return immediately.
This requires moving the reuseport_has_conns() logic into the callers.
While we are here, get rid of inline directives as they do not belong
in foo.c files.
The other changes were cases of more straightforward overlapping
modifications.
Signed-off-by: David S. Miller <davem@davemloft.net>
Rework the remaining setsockopt code to pass a sockptr_t instead of a
plain user pointer. This removes the last remaining set_fs(KERNEL_DS)
outside of architecture specific code.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Acked-by: Stefan Schmidt <stefan@datenfreihafen.org> [ieee802154]
Acked-by: Matthieu Baerts <matthieu.baerts@tessares.net>
Signed-off-by: David S. Miller <davem@davemloft.net>
There is a current limit of 1920 registered dmb buffers per ISM device
for smc-d. One link group can contain 255 connections, each connection
is using one dmb buffer. When the connection is closed then the
registered buffer is held in a queue and is reused by the next
connection. When a link group is 'full' then another link group is
created and uses an own buffer pool. The link groups are added to a
list using list_add() which puts a new link group to the first position
in the list.
In the situation that many connections are opened (>1920) and a few of
them stay open while others are closed quickly we end up with at least 8
link groups. For a new connection a matching link group is looked up,
iterating over the list of link groups. The trailing 7 link groups
all have registered dmb buffers which could be reused, while the first
link group has only a few dmb buffers and then hit the 1920 limit.
Because the first link group is not full (255 connection limit not
reached) it is chosen and finally the connection falls back to TCP
because there is no dmb buffer available in this link group.
There are multiple ways to fix that: using list_add_tail() allows
to scan older link groups first for free buffers which ensures that
buffers are reused first. This fixes the problem for smc-r link groups
as well. For smc-d there is an even better way to address this problem
because smc-d does not have the 255 connections per link group limit.
So fix the problem for smc-d by allowing large link groups.
Fixes: c6ba7c9ba4 ("net/smc: add base infrastructure for SMC-D and ISM")
Reviewed-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
To get a send slot smc_wr_tx_get_free_slot() is called, which might
wait for a free slot. When smc_wr_tx_get_free_slot() returns there is a
check if the connection was killed in the meantime. In that case don't
only return an error, but also put back the free slot.
Fixes: b290098092 ("net/smc: cancel send and receive for terminated socket")
Reviewed-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Just check for a NULL method instead of wiring up
sock_no_{get,set}sockopt.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Acked-by: Marc Kleine-Budde <mkl@pengutronix.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
When a listen socket is closed then all non-accepted sockets in its
accept queue are to be released. Inside __smc_release() the helper
smc_restore_fallback_changes() restores the changes done to the socket
without to check if the clcsocket has a file set. This can result in
a crash. Fix this by checking the file pointer first.
Reviewed-by: Ursula Braun <ubraun@linux.ibm.com>
Fixes: f536dffc0b ("net/smc: fix closing of fallback SMC sockets")
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Two buffers are allocated for each SMC connection. Each buffer is
added to a buffer list after creation. When the second buffer
allocation fails, the first buffer is freed but not deleted from
the list. This might result in crashes when another connection picks
up the freed buffer later and starts to work with it.
Reviewed-by: Ursula Braun <ubraun@linux.ibm.com>
Fixes: 6511aad3f0 ("net/smc: change smc_buf_free function parameters")
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The dma related ...sync_sg... functions check the link state before the
dma function is actually called. But the check in smc_link_usable()
allows links in ACTIVATING state which are not yet mapped to dma memory.
Under high load it may happen that the sync_sg functions are called for
such a link which results in an debug output like
DMA-API: mlx5_core 0002:00:00.0: device driver tries to sync
DMA memory it has not allocated [device address=0x0000000103370000]
[size=65536 bytes]
To fix that introduce a helper to check for the link state ACTIVE and
use it where appropriate. And move the link state update to ACTIVATING
to the end of smcr_link_init() when most initial setup is done.
Reviewed-by: Ursula Braun <ubraun@linux.ibm.com>
Fixes: d854fcbfae ("net/smc: add new link state and related helpers")
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
As smc client the delete link requests are assigned to the flow when
_any_ flow is active. This may break other flows that do not expect
delete link requests during their handling. Fix that by assigning the
request only when an add link flow is active. With that fix the code
for smc client and smc server is the same, so remove the separate
handling.
Reviewed-by: Ursula Braun <ubraun@linux.ibm.com>
Fixes: 9ec6bf19ec ("net/smc: llc_del_link_work and use the LLC flow for delete link")
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
When a new ib device is up smc will send an add link invitation to the
peer if needed. This is currently done with rudimentary flow control.
Under high workload these add link invitations can disturb other llc
flows because they arrive unexpected. Fix this by integrating the
invitations into the normal llc event flow and handle them as a flow.
While at it, check for already assigned requests in the flow before
the new add link request is assigned.
Reviewed-by: Ursula Braun <ubraun@linux.ibm.com>
Fixes: 1f90a05d9f ("net/smc: add smcr_port_add() and smcr_link_up() processing")
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
To be save from unexpected or late llc response messages check if the
arrived message fits to the current flow type and drop out-of-flow
messages. And drop it when there is already a response assigned to
the flow.
Reviewed-by: Ursula Braun <ubraun@linux.ibm.com>
Fixes: ef79d439cd ("net/smc: process llc responses in tasklet context")
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Before an smc ib device is used the first time for an smc link it is
lazily initialized. When there are 2 active link groups and a new ib
device is brought online then it might happen that 2 link creations run
in parallel and enter smc_ib_setup_per_ibdev(). Both allocate new send
and receive completion queues on the device, but only one set of them
keeps assigned and the other leaks.
Fix that by protecting the setup and cleanup code using a mutex.
Reviewed-by: Ursula Braun <ubraun@linux.ibm.com>
Fixes: f3c1deddb2 ("net/smc: separate function for link initialization")
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
For new rdma connections the SMC server assigns the link and sends the
link data in the clc accept message. To match the correct link use not
only the qp_num but also the gid and the mac of the links. If there are
equal qp_nums for different links the wrong link would be chosen.
Reviewed-by: Ursula Braun <ubraun@linux.ibm.com>
Fixes: 0fb0b02bd6 ("net/smc: adapt SMC client code to use the LLC flow")
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
In a link-down condition we notify the SMC server and expect that the
server will finally trigger the link clear processing on the client
side. This could fail when anything along this notification path goes
wrong. Clear the link as part of SMC client link-down processing to
prevent dangling links.
Reviewed-by: Ursula Braun <ubraun@linux.ibm.com>
Fixes: 541afa10c1 ("net/smc: add smcr_port_err() and smcr_link_down() processing")
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
A delete link could arrive during confirm link processing. Handle this
situation directly in smc_llc_srv_conf_link() rather than using the
logic in smc_llc_wait() to avoid the unexpected message handling there.
Reviewed-by: Ursula Braun <ubraun@linux.ibm.com>
Fixes: 1551c95b61 ("net/smc: final part of add link processing as SMC server")
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>