This patch adds support for the "discoverable" flag of the
Add Advertising command.
Signed-off-by: Arman Uguray <armansito@chromium.org>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This patch adds support for the "connectable mode" flag of the
Add Advertising command.
Signed-off-by: Arman Uguray <armansito@chromium.org>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
When the user of the management interface is not trusted, then it only
has access to a limited set of commands and events. When providing the
list of supported commands and events take the trusted vs untrusted
status of the user into account and return different lists.
This way the untrusted user knows exactly which commands it can
execute and which events it can receive. So no guesswork needed.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
This patch implements support for the timeout parameter of the
Add Advertising command.
Signed-off-by: Arman Uguray <armansito@chromium.org>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This patch implements setting the Scan Response data provided as part
of an advertising instance through the Add Advertising command.
Signed-off-by: Arman Uguray <armansito@chromium.org>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This patch adds the most basic implementation for the
"Add Advertisement" command. All state updates between the
various HCI settings (POWERED, ADVERTISING, ADVERTISING_INSTANCE,
and LE_ENABLED) has been implemented. The command currently
supports only setting the advertising data fields, with no flags
and no scan response data.
Signed-off-by: Arman Uguray <armansito@chromium.org>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Using the HCI_MAX_AD_LENGTH for the max advertising data and max scan
response data length makes more sense than hardcoding the value.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Currently the enabling of LE on LE only devices causes an error. This
is a bit difference from other commands where trying to set the same
existing settings causes a positive response. Fix this behavior for
this single corner case.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
The mgmt.c file should be reserved purely for HCI_CHANNEL_CONTROL. The
mgmt_control() function in it is already completely generic and has a
single user in hci_sock.c. This patch moves the function there and
renames it a bit more appropriately to hci_mgmt_cmd() (as it's a command
dispatcher).
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
In order to make the mgmt command handling more generic we can't have a
direct call to mgmt_init_hdev() from mgmt_control(). This patch adds a
new callback to struct hci_mgmt_chan. And sets it to point to the
mgmt_init_hdev() function for the HCI_CHANNEL_CONTROL instance.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
There are several mgmt protocol features that will be needed by more
than just the current HCI_CHANNEL_CONTROL. These include sending generic
events as well as handling pending commands. This patch moves these
functions out from mgmt.c to a new mgmt_util.c file.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
To be able to have pending commands for different HCI channels we need
to be able to distinguish for which channel a command was sent to. The
channel information is already part of the socket data and can be
fetched using the recently added hci_sock_get_channel() function. To not
require all mgmt.c code to pass an extra channel parameter this patch
also adds a helper pending_find() & pending_find_data() functions which
act as a wrapper to the new mgmt_pending_find() & mgmt_pending_find_data()
APIs.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
When doing scan through mgmt api, some controllers can do both le and
classic scan at same time. They can be distinguished by
HCI_QUIRK_SIMULTANEOUS_DISCOVERY set.
This patch enables them to use this feature when doing dual mode scan.
Instead of doing le, then classic scan, both scans are run at once.
Signed-off-by: Jakub Pawlowski <jpawlowski@google.com>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
This patch refactor BR/EDR inquiry and LE scan triggering logic into
separate methods.
Signed-off-by: Jakub Pawlowski <jpawlowski@google.com>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
When a different user requests a new set of local out-of-band data, then
inform all previous users that the data has been updated. To limit the
scope of users, the updates are limited to previous users. If a user has
never requested out-of-band data, it will also not see the update.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
The length of the respone packet for Read Local OOB Extended Data
command has a calculation error. In case LE Secure Connections support
is not enabled, the actual response is shorter. Keep this in mind and
update the value accordingly.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
In case LE Secure Connections is not enabled, then the command for
returning local out-of-band data should not include the confirmation
and random value for LE SC pairing. All other fields are still valid,
but these two need to be left out. In that case it is also no needed
to generate the public/private key pair for out-of-band pairing.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Then the local out-of-band data for LE SC pairing is requested via Read
Local OOB Extended Data command, then fill in the values generated by
the smp_generate_oob function. Every call of this command will overwrite
previously generated values.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
This adds support for the simplest possible version of Read Local OOB
Extended Data management command. It includes all mandatory fields,
but none of the actual pairing related ones.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
The eir_append_data helper function is needed for generating the
extended local OOB data fields. So move it up into the right location.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
This adds support for the simplest possible version of Read Advertising
Features management command. It allows basic testing of the interface.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Changes to the global configuration updates like settings, class of
device, name etc. can be received by every user. They are allowed to
read them in the first place so provide the updates via events as
well. Otherwise untrusted users start polling for updates and that
is not a desired behavior.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Check the required trust level of each management command with the trust
level of the management socket. If it does not match up, then return the
newly introduced permission denied error.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
The flags field for the management command table will be always
initialized to zero and thus no need to do that manually.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Some management commands are safe to be accessed from any user without
special permissions. First step for allowing access to any of these
commands from untrusted application is to mark them accordingly.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
With the introduction of trusted socket flag for control and monitor
channels, it is now possible to use a single function for sending
packets to these sockets. And with that consolidate the handling.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
The Read Extended Contoller Index List command can be used for
retrieving the complete list of local available controllers. This
included configured, unconfigured and also AMP controllers.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
This introduces support for using Extended Index Added and Extended
Index Removed events. These events contain the controller type and
also the hardware bus information from the driver.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
For sending Index Added, Index Removed, Unconfigured Index Added and
Unconfigured Index Removed managment events the new helper functions
allows taking into account if these events are enabled for a certain
management socket or not.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
With the extension of hdev->dev_flags utilizing a bitmap now, the space
is no longer restricted. Merge the hdev->dbg_flags into hdev->dev_flags
to save space on 64-bit architectures. On 32-bit architectures no size
reduction happens.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Instead of manually coding test_and_set_bit on hdev->dev_flags all the
time, use hci_dev_test_and_set_flag helper macro.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Instead of manually coding test_and_clear_bit on hdev->dev_flags all the
time, use hci_dev_test_and_clear_flag helper macro.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Instead of manually coding test_and_change_bit on hdev->dev_flags all the
time, use hci_dev_test_and_change_flag helper macro.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Instead of manually coding change_bit on hdev->dev_flags all the time,
use hci_dev_change_flag helper macro.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Instead of manually coding clear_bit on hdev->dev_flags all the time,
use hci_dev_clear_flag helper macro.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Instead of manually coding set_bit on hdev->dev_flags all the time,
use hci_dev_set_flag helper macro.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Instead of manually coding test_bit on hdev->dev_flags all the time,
use hci_dev_test_flag helper macro.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
The patch adds a second advertising setting that allows switching of the
controller into connectable mode independent of the global connectable
setting.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
This patch increments the management interface revision due to
introduction of new static address setting and fixes for the
fast connectable feature.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
To make the behavior predictable when attempting to pair with a device
for which we already have a Link Key or Long Term Key, this patch adds a
new 'Already Paired' error which gets sent in such a scenario.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
To maximize the usability of the Fast Connectable feature we should make
it possible to set (or unset) it at any given moment. This means
removing the dependency on the 'connectable' setting as well as the
'powered' setting. The former makes also sense since page scan may get
enabled through add_device even if 'connectable' is false. To keep the
setting available over power cycles its flag also needs to be removed
from the flags that are cleared upon HCI_Reset.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Currently the mgmt_event() function is only capable of sending to
HCI_CHANNEL_CONTROL. To void having to change all users of it, add a new
mgmt_send_event() function that takes a channel parameter, and make the
old mgmt_event() a wrapper that passes MGMT_CHANNEL_CONTROL to it.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This patch renames the pending_cmd struct (used for tracking pending mgmt
commands) to mgmt_pending_cmd, so that it can be moved to a more generic
place and be used also by other modules using other HCI channels.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This patch renames the cmd_complete() function to mgmt_cmd_complete() in
preparation of making it a generic helper for other modules to use too.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This patch renames the cmd_status() function to mgmt_cmd_status() in
preparation of making it a generic helper for other modules to use too.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
In order to completely generalize the mgmt command handling we need to
move away command-specific information from mgmt_control() into the
actual command table. This patch adds a new 'flags' field to the handler
entries which can now contain the following command specific
information:
- Command takes variable length parameters
- Command doesn't target any specific HCI device
- Command can be sent when the HCI device is unconfigured
After this the mgmt_control() function is completely generic and can
potentially be reused by new HCI channels.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This patch converts the existing mgmt code to use the newly introduced
generic API for registering HCI channels with mgmt-like semantics.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Currently it is not possible to determine if the static address is used
by the controller. It is also not possible to determine if using a
static on a dual-mode controller with disabled BR/EDR is possible or
not.
To address this issue, introduce a new setting called static-address. If
support for this setting is signaled that means that the kernel supports
using static addresses. And if used on dual-mode controllers with BR/EDR
disabled it means that a configured static address can be used.
In addition utilize the same setting for the list of current active
settings that indicates if a static address is configured and if that
address will be actually used.
With this in mind the existing Set Static Address management command
has been extended to return the current settings. That way the caller
of that command can easily determine if the programmed address will
be used or if extra steps are required.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>