This patch adds error checking of ctrlmode values for CAN devices. As
an example all availabe bits are implemented in the mcp251x driver.
Signed-off-by: Christian Pellegrin <chripell@fsfe.org>
Acked-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
To prevent the CAN drivers to operate on invalid socketbuffers the skbs are
now checked and silently dropped at the xmit-function consistently.
Also the netdev stats are consistently using the CAN data length code (dlc)
for [rx|tx]_bytes now.
Signed-off-by: Oliver Hartkopp <oliver@hartkopp.net>
Acked-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The main differences compared to the MSCAN on the MPC5200 are:
- More flexibility in choosing the CAN source clock and frequency:
Three different clock sources can be selected: "ip", "ref" or "sys".
For the latter two, a clock divider can be defined as well. If the
clock source is not specified by the device tree, we first try to
find an optimal CAN source clock based on the system clock. If that
is not possible, the reference clock will be used.
- The behavior of bus-off recovery is configurable:
To comply with the usual handling of Socket-CAN bus-off recovery,
"recovery on request" is selected (instead of automatic recovery).
Note that only MPC5121 Rev. 2 and later is supported.
Signed-off-by: Wolfgang Grandegger <wg@denx.de>
Reviewed-by: Wolfram Sang <w.sang@pengutronix.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
The start_xmit function of the MSCAN Driver did return improperly if
the CAN dlc check failed (skb not freed and invalid return code). This
patch adds a proper check of the frame lenght and data size and returns
now correctly. The invalid skb packets are dropped silently as suggested
by David Miller in the thread "[RFC] ndo_validate_skb: Let the netdev
check a valid skb content" on the netdev mailing list.
Furthermore, a typo has been fixed.
Signed-off-by: Wolfgang Grandegger <wg@denx.de>
Reviewed-by: Wolfram Sang <w.sang@pengutronix.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
A valid CAN dataframe can have a data length code (DLC) of 0 .. 8 data bytes.
When reading the CAN controllers register the 4-bit value may contain values
from 0 .. 15 which may exceed the reserved space in the socket buffer!
The ISO 11898-1 Chapter 8.4.2.3 (DLC field) says that register values > 8
should be reduced to 8 without any error reporting or frame drop.
This patch introduces a new helper macro to cast a given 4-bit data length
code (dlc) to __u8 and ensure the DLC value to be max. 8 bytes.
The different handlings in the rx path of the CAN netdevice drivers are fixed.
Signed-off-by: Oliver Hartkopp <oliver@hartkopp.net>
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Not all hardcoded values have been replaced as this made the code quite
unreadable. IMHO this compromise serves the purpose of readability.
Signed-off-by: Wolfram Sang <w.sang@pengutronix.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
- use extern where apropriate
- don't export symbols
Signed-off-by: Wolfram Sang <w.sang@pengutronix.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
- remove whitespaces
- use ! and ?: when apropriate
- make braces consistent
Signed-off-by: Wolfram Sang <w.sang@pengutronix.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
Taken from socketcan-svn, fixed remaining todos, cleaned up, tested with a
phyCORE-MPC5200B-IO and a custom board.
Signed-off-by: Wolfram Sang <w.sang@pengutronix.de>
Cc: Wolfgang Grandegger <wg@grandegger.com>
Cc: Grant Likely <grant.likely@secretlab.ca>
Cc: David Miller <davem@davemloft.net>
Signed-off-by: David S. Miller <davem@davemloft.net>