Commit Graph

12 Commits

Author SHA1 Message Date
Guenter Roeck
98591dbe63 hwmon: (max34440) Add support for peak attributes
Add support for voltage, current, and temperature peak (historic maximum)
attributes.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28 17:09:54 -07:00
Guenter Roeck
70e94b276c hwmon: (max8688) Add support for peak attributes
Add support for voltage, current, and temperature peak (historic maximum)
attributes.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
2011-07-28 17:09:53 -07:00
Guenter Roeck
8ebed85450 hwmon: (max16064) Add support for peak attributes
Add support for voltage and temperature peak (historic maximum) attributes.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28 17:09:53 -07:00
Guenter Roeck
c576e30cd0 hwmon: (adm1275) Add support for peak attributes
Add support for voltage and current peak (historic maximum) attributes.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28 17:09:52 -07:00
Guenter Roeck
6f183d33a0 hwmon: (pmbus) Add support for peak attributes
Most PMBus devices provide manufacturer specific commands to read low and/or
high peak values for some or all of its sensors.

To support providing those values as lowest/highest attributes to the user,
introduce virtual PMBus commands. Those commands reside outside the normal
command set and have to be implemented in device specific code, which map the
virtual commands to device specific commands.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28 17:09:32 -07:00
Guenter Roeck
c6bfb767e4 hwmon: (pmbus) Strengthen check for status register existence
With virtual register page support, it is now possible that the status register
on virtual pages does not exist or is itself virtual. To take this into account
when creating alarm attributes, generate those attributes only if the status
register on the respective page is known to exist.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28 17:02:40 -07:00
Guenter Roeck
9c1ed8941d hwmon: (pmbus) Add support for virtual pages
Some PMBus chips have non-standard sensor registers. An easy way to
support such sensors is to introduce virtual pages and map the non-standard
registers into standard registers on an extra page.

For this to work, the code verifying if the configured number of pages exists
has to be removed. Since a wrong number of pages can only be configured in a
front-end driver, this should not have a practical impact since the resulting
errors should be found during development and testing.

Also, functions to read the chip status while checking if a command register
exists must be modified to no longer set the page register before reading the
status, since the physical page associated with the checked register may not
exist. This does not make a functional difference since the page was already set
when the attempt to read the register was made.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28 17:02:15 -07:00
Guenter Roeck
46243f3ab4 hwmon: (pmbus) Support reading and writing of word registers in device specific code
Some PMBus devices use non-standard registers for some of the sensors and/or
limits. To support such devices, add code to support reading and writing of word
size registers in device specific code.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28 16:55:13 -07:00
Guenter Roeck
2bd05bf4d2 hwmon: (pmbus) Increase attribute name size
Some hwmon sysfs attributes have a length of 20 bytes (plus terminating 0).
I2C_NAME_SIZE is defined as 20 and thus can not be used to define the length
of hwmon sysfs attributes. Replace it with PMBUS_NAME_SIZE, set to 24.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28 15:31:18 -07:00
Guenter Roeck
e0455e380b hwmon: (pmbus) Add ADP4000, NCP4200 and NCP4208 to list of supported devices
Add ADP4000, NCP4200 and NCP4208 to the list of devices supported by the generic
PMBus driver, and add device IDs to enable explicit instantiation.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
Acked-by: Jean Delvare <khali@linux-fr.org>
2011-07-28 15:31:18 -07:00
Guenter Roeck
1061d8518f hwmon: (pmbus) Add support for VID output voltage mode
In VID mode, output voltages are measured and reported as VID values, and
have to be converted to voltages using VID conversion tables or functions.
Support is added for VR11 only at this time.

This patch enables support for PMBus devices supporting VID VR11 based output
voltage selection such as NCP4200 and NCP4208.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28 15:31:11 -07:00
Guenter Roeck
9d2ecfb768 hwmon: (pmbus) Move PMBus drivers to drivers/hwmon/pmbus
Since the number of PMBus drivers is getting large, move them into
directory drivers/hwmon/pmbus to improve readability and scalability.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28 11:47:53 -07:00