The IIO_HUMIDITYRELATIVE channel was being incorrectly reported back
as percent when it should have been milli percent. This is via an
incorrect scale value being returned to userspace.
Signed-off-by: Chris Lesiak <chris.lesiak@licor.com>
Acked-by: Matt Ranostay <matt.ranostay@konsulko.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The iio_triggered_buffer_postenable() hook should be called first to
attach the poll function and the iio_triggered_buffer_predisable() hook
should be called last in the predisable hook.
This change updates the driver to attach/detach the poll func in the
correct order.
Signed-off-by: Alexandru Ardelean <alexandru.ardelean@analog.com>
Reviewed-by: Matt Ranostay <matt.ranostay@konsulko.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Use device-managed APIs to simplify the code.
The remove functions are redundant now and can
be deleted.
Signed-off-by: Chuhong Yuan <hslester96@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Add GPLv2+ SPDX identifier and update email for author's drivers.
Signed-off-by: Matt Ranostay <matt.ranostay@konsulko.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The equivalent of both of these are now done via macro magic when
the relevant register calls are made. The actual structure
elements will shortly go away.
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Reviewed-by: Lars-Peter Clausen <lars@metafoo.de>
Add of_match_table and point it to a list of compatible device tree
device id's.
Signed-off-by: Michael Stecklein <m-stecklein@ti.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Include datasheet links, add i2c_device_id entries, and update
kconfig help for compatible HDC10xx devices: HDC1000, HDC1008,
HDC1010, HDC1050, and HDC1080.
Signed-off-by: Michael Stecklein <m-stecklein@ti.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Check for attribute_group structures that are only stored in the
attrs filed of iio_info structure. As the attrs field of iio_info
structures is constant, so these attribute_group structures can also be
declared constant.
Done using coccinelle:
@r1 disable optional_qualifier @
identifier i;
position p;
@@
static struct attribute_group i@p = {...};
@ok1@
identifier r1.i;
position p;
struct iio_info x;
@@
x.attrs=&i@p;
@bad@
position p!={r1.p,ok1.p};
identifier r1.i;
@@
i@p
@depends on !bad disable optional_qualifier@
identifier r1.i;
@@
static
+const
struct attribute_group i={...};
@depends on !bad disable optional_qualifier@
identifier r1.i;
@@
+const
struct attribute_group i;
File size before:
text data bss dec hex filename
3459 488 0 3947 f6b drivers/iio/humidity/hdc100x.o
File size after:
text data bss dec hex filename
3507 424 0 3931 f5b drivers/iio/humidity/hdc100x.o
Signed-off-by: simran singhal <singhalsimran0@gmail.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Triggered buffer support uses the HDC100X's dual acquisition mode
to read both humidity and temperature in one shot.
This patch depends on
447136effbf4 ("iio: humidity: hdc100x: fix sensor data reads of
temp and humidity")
Signed-off-by: Alison Schofield <amsfield22@gmail.com>
Cc: Daniel Baluta <daniel.baluta@gmail.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Replace the i2c_smbus_read_byte commmands used to retrieve the sensor
data with an i2c_master_recv command.
The smbus read byte method fails because the device does not expect a
stop condition after sending the first byte. When we issue the second
read, we are getting the first byte again. Net effect is that of the 14
bits used for the measurement, the 8 most significant bits are correct,
the lower 6 are not.
None of the smbus read protocols follow the pattern this device requires
(S Addr Rd [A] Data [A] Data NA P), hence the switch to an i2c receive
transaction.
Applicable from original introduction of this driver, but will require
backporting due to churn in the code.
Signed-off-by: Alison Schofield <amsfield22@gmail.com>
Cc: Daniel Baluta <daniel.baluta@gmail.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Shifting sensor data to the right 2 bits was incorrect and caused the
scaling values + offsets to be invalid.
Reported-by: Alison Schofield <amsfield22@gmail.com>
Signed-off-by: Matt Ranostay <mranostay@gmail.com>
Tested-by: Alison Schofield <amsfield22@gmail.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
IIO_TEMP channel was being incorrectly reported back as Celsius when it
should have been milliCelsius. This is via an incorrect scale value being
returned to userspace.
Signed-off-by: Matt Ranostay <mranostay@gmail.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Apply the correct mask to enable all available humidity integration
times. Currently, the driver defaults to 6500 and all is okay with that.
However, if 3850 is selected we get a stuck bit and can't change back
to 6500 or select 2500. (Verified with HDC1008)
Signed-off-by: Alison Schofield <amsfield22@gmail.com>
Cc: Daniel Baluta <daniel.baluta@gmail.com>
Reviewed-by: Matt Ranostay <mranostay@gmail.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Previously most drivers that used a i2c_check_functionality() check
condition required various error codes on failure. This patchset
converts to a standard of -EOPNOTSUPP
Signed-off-by: Matt Ranostay <mranostay@gmail.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Previous offset wasn't applied in the correct order and invalid.
This patchset fixes this issue, and also has the correct scale value
applied to the offset.
Signed-off-by: Matt Ranostay <mranostay@gmail.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Add support for the HDC100x temperature and humidity sensors
including the resistive heater element.
Signed-off-by: Matt Ranostay <mranostay@gmail.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>