Fix checkpatch warnings about use of spaces with operators:
spaces preferred around that '*' (ctx:VxV)
This has been recently added to checkpatch.
Signed-off-by: Kalle Valo <kvalo@qca.qualcomm.com>
After commit cf4f21938e ("kbuild: Allow to specify composite modules
with modname-m"), thermal.c gets included in the driver and the build
fails with
drivers/net/wireless/ath/ath10k/thermal.c:119:6: error: redefinition of ‘ath10k_thermal_event_temperature’
drivers/net/wireless/ath/ath10k/thermal.h:54:20: note: previous definition of ‘ath10k_thermal_event_temperature’ was here
drivers/net/wireless/ath/ath10k/thermal.c:136:6: error: redefinition of ‘ath10k_thermal_set_throttling’
drivers/net/wireless/ath/ath10k/thermal.h:59:20: note: previous definition of ‘ath10k_thermal_set_throttling’ was here
drivers/net/wireless/ath/ath10k/thermal.c:162:5: error: redefinition of ‘ath10k_thermal_register’
drivers/net/wireless/ath/ath10k/thermal.h:45:19: note: previous definition of ‘ath10k_thermal_register’ was here
drivers/net/wireless/ath/ath10k/thermal.c:216:6: error: redefinition of ‘ath10k_thermal_unregister’
drivers/net/wireless/ath/ath10k/thermal.h:50:20: note: previous definition of ‘ath10k_thermal_unregister’ was here
Change the #ifdef to reflect the new kbuild behavior.
Reported-by: kbuild test robot <fengguang.wu@intel.com>
Acked-by: Kalle Valo <kvalo@qca.qualcomm.com>
Signed-off-by: Michal Marek <mmarek@suse.com>
Thermal throttling is not handled in software restart and device
bootup. Also it needs to be configured whenever quiet period got
updated. Fix that.
Reported-by: Matthias Kaehlcke <mka@google.com>
Signed-off-by: Rajkumar Manoharan <rmanohar@qti.qualcomm.com>
Signed-off-by: Kalle Valo <kvalo@qca.qualcomm.com>
Setting the sysfs attribute ends up configuring the duty cycle,
but the interface through which the attribute is exposed
(cooling_device) is for setting the throttle/cooling state. This
is confusing the user. Hence renaming the cooling device interfaces
for better readability.
Cc: Matthias Kaehlcke <mka@google.com>
Signed-off-by: Rajkumar Manoharan <rmanohar@qti.qualcomm.com>
Signed-off-by: Kalle Valo <kvalo@qca.qualcomm.com>
Add support to configure quiet period (in milliseconds) via debugfs.
This is useful to experiment different quiet period values along with
different throttle ratio.
echo 100 > /sys/kernel/debug/ieee80211/phyX/ath10k/quiet_period
Signed-off-by: Rajkumar Manoharan <rmanohar@qti.qualcomm.com>
Signed-off-by: Kalle Valo <kvalo@qca.qualcomm.com>
Allow user to configure the duty cycle upto 100%. Since thermal
mitigation algorithm is running in user space, remove the driver
level limitation and let the user to control the temperature.
Signed-off-by: Rajkumar Manoharan <rmanohar@qti.qualcomm.com>
Signed-off-by: Kalle Valo <kvalo@qca.qualcomm.com>
Temperature sensor generates electrical analog voltage from temperature
of each chain. The analog voltage is converted to digital value through
ADC. For reading temperature values fom user space, hw monitoring device
is used.
Whenever the user requests for current temperature, the driver sends WMI
command and wait for response. For reading temperature,
cat /sys/class/ieee80211/phy*/device/hwmon/hwmon2/temp1_input
Signed-off-by: Rajkumar Manoharan <rmanohar@qti.qualcomm.com>
Signed-off-by: Kalle Valo <kvalo@qca.qualcomm.com>
Thermal cooling device support is added to control the temperature
by throttling the data transmission for the given duration. Throttling
is done using hw MAC quiet time setting. Period, duration and offset
from TBTT can be set up to quiet the MAC transmits for the required duty
cycle (% of quiet duration). The thermal device allows user to configure
duty cycle.
The quiet params are derived as follows.
period = max(25TU, beacon interval / number of bss)
duration = period * duty cycle / 100
Quiet mode can be disabled by setting the duty cycle to 0. The cooling
device can be found under /sys/class/thermal/cooling_deviceX/.
Corresponding soft link to this device can be found under phy folder.
/sys/class/ieee80211/phy*/device/cooling_device.
To set duty cycle as 40%,
echo 40 >/sys/class/ieee80211/phy*/device/cooling_device/cur_state
Signed-off-by: Rajkumar Manoharan <rmanohar@qti.qualcomm.com>
Signed-off-by: Kalle Valo <kvalo@qca.qualcomm.com>