Wolfram Sang
77f9f77218 HID: hid-sensor-custom: simplify getting .driver_data
We should get 'driver_data' from 'struct device' directly. Going via
platform_device is an unneeded step back and forth.

Signed-off-by: Wolfram Sang <wsa+renesas@sang-engineering.com>
Acked-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Reviewed-by: Simon Horman <horms+renesas@verge.net.au>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2019-03-27 14:06:19 +01:00
Hans de Goede
0145b50566 iio/hid-sensors: Fix IIO_CHAN_INFO_RAW returning wrong values for signed numbers
Before this commit sensor_hub_input_attr_get_raw_value() failed to take
the signedness of 16 and 8 bit values into account, returning e.g.
65436 instead of -100 for the z-axis reading of an accelerometer.

This commit adds a new is_signed parameter to the function and makes all
callers pass the appropriate value for this.

While at it, this commit also fixes up some neighboring lines where
statements were needlessly split over 2 lines to improve readability.

Signed-off-by: Hans de Goede <hdegoede@redhat.com>
Acked-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Acked-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2018-11-16 11:42:12 +00:00
Linus Torvalds
a9a08845e9 vfs: do bulk POLL* -> EPOLL* replacement
This is the mindless scripted replacement of kernel use of POLL*
variables as described by Al, done by this script:

    for V in IN OUT PRI ERR RDNORM RDBAND WRNORM WRBAND HUP RDHUP NVAL MSG; do
        L=`git grep -l -w POLL$V | grep -v '^t' | grep -v /um/ | grep -v '^sa' | grep -v '/poll.h$'|grep -v '^D'`
        for f in $L; do sed -i "-es/^\([^\"]*\)\(\<POLL$V\>\)/\\1E\\2/" $f; done
    done

with de-mangling cleanups yet to come.

NOTE! On almost all architectures, the EPOLL* constants have the same
values as the POLL* constants do.  But they keyword here is "almost".
For various bad reasons they aren't the same, and epoll() doesn't
actually work quite correctly in some cases due to this on Sparc et al.

The next patch from Al will sort out the final differences, and we
should be all done.

Scripted-by: Al Viro <viro@zeniv.linux.org.uk>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2018-02-11 14:34:03 -08:00
Al Viro
afc9a42b74 the rest of drivers/*: annotate ->poll() instances
Signed-off-by: Al Viro <viro@zeniv.linux.org.uk>
2017-11-28 11:06:58 -05:00
Jiri Kosina
d29ed11bb7 Merge branch 'for-4.14/ish' into for-linus
- bring consistency into logical minimum numbering in sensor-hub
  driver, from Srinivas Pandruvada
2017-09-05 11:10:13 +02:00
Arvind Yadav
0be2bfdc23 HID: sensor: constify platform_device_id
platform_device_id are not supposed to change at runtime. All functions
working with platform_device_id provided by <linux/platform_device.h>
work with const platform_device_id. So mark the non-const structs as
const.

Signed-off-by: Arvind Yadav <arvind.yadav.cs@gmail.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2017-08-15 11:01:14 +02:00
Arvind Yadav
58ee3e08aa HID: sensor: constify attribute_group structures.
attribute_group are not supposed to change at runtime. All functions
working with attribute_group provided by <linux/sysfs.h> work with
const attribute_group. So mark the non-const structs as const.

Signed-off-by: Arvind Yadav <arvind.yadav.cs@gmail.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2017-08-03 13:38:30 +02:00
Ooi, Joyce
4c4480aad0 HID: sensor: fix attributes in HID sensor interface
User is unable to access to input-X-yyy and feature-X-yyy where
X is a hex value and more than 9 (e.g. input-a-yyy, feature-b-yyy) in HID
sensor custom sysfs interface.
This is because when creating the attribute, the attribute index is
written to using %x (hex). However, when reading and writing values into
the attribute, the attribute index is scanned using %d (decimal). Hence,
user is unable to access to attributes with index in hex values
(e.g. 'a', 'b', 'c') but able to access to attributes with index in
decimal values (e.g. 1, 2, 3,..).
This fix will change input-%d-%x-%s and feature-%d-%x-%s to input-%x-%x-%s
and feature-%x-%x-%s in show_values() and store_values() accordingly.

Signed-off-by: Ooi, Joyce <joyce.ooi@intel.com>
Reviewed-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Acked-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2016-11-05 16:56:09 +01:00
Srinivas Pandruvada
4a7de0519d HID: sensor: Custom and Generic sensor support
HID Sensor Spec defines two usage ids for custom sensors

	HID_USAGE_SENSOR_TYPE_OTHER_CUSTOM (0x09, 0xE1)
	HID_USAGE_SENSOR_TYPE_OTHER_GENERIC(0x09, 0xE2)

	In addition the standard also defines usage ids for custom fields.
The purpose of these sensors is to extend the functionality or provide a way to
obfuscate the data being communicated by a sensor. Without knowing the mapping
between the data and its encapsulated form, it is difficult for an driver to
determine what data is being communicated by the sensor.  This allows some
differentiating use cases, where vendor can provide applications.  Since these
can't be represented by standard sensor interfaces like IIO, we present these
as fields with

- type (input/output)
- units
- min/max
- get/set value

In addition an dev interface to transfer report events. Details about this
interface is described in /Documentation/hid/hid-sensor.txt.  Manufacturers
should not use these ids for any standard sensors, otherwise the the
product/vendor id can be added to black list.

Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Reviewed-by: Jonathan Cameron <jic23@kernel.org>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>