Commit Graph

4 Commits

Author SHA1 Message Date
Matthew R. Ochs
1a47401bb3 cxlflash: Fix to avoid corrupting port selection mask
The port selection mask of a LUN can be corrupted when the manage LUN
ioctl (DK_CXLFLASH_MANAGE_LUN) is issued more than once for any device.

This mask indicates to the AFU which port[s] can be used for a data
transfer to/from a particular LUN. The mask is critical to ensuring the
correct behavior when using the virtual LUN function of this adapter.
When the mask is configured for both ports, an I/O may be sent to either
port as the AFU assumes that each port has access to the same physical
device (specified by LUN ID in the port LUN table).

In a situation where the mask becomes incorrectly configured to reflect
access to both ports when in fact there is only access through a single
port, an I/O can be targeted to the wrong physical device. This can lead
to data corruption among other ill effects (e.g. security leaks).

The cause for this corruption is the assumption that the ioctl will only
be called a second time for a LUN when it is being configured for access
via a second port. A boolean 'newly_created' variable is used to
differentiate between a LUN that was created (and subsequently configured
for single port access) and one that is destined for access across both
ports. While initially set to 'true', this sticky boolean is toggled to
the 'false' state during a lookup on any next ioctl performed on a device
with a matching WWN/WWID. The code fails to realize that the match could
in fact be the same device calling in again. From here, an assumption is
made that any LUN with 'newly_created' set to 'false' is configured for
access over both ports and the port selection mask is set to reflect this.
Any future attempts to use this LUN for hosting a virtual LUN will result
in the port LUN table being incorrectly programmed.

As a remedy, the 'newly_created' concept was removed entirely and replaced
with code that always constructs the port selection mask based upon the
SCSI channel of the LUN being accessed. The bits remain sticky, therefore
allowing for a device to be accessed over both ports when that is in fact
the correct physical configuration.

Also included in this commit are a few minor related changes to enhance
the fix and provide better debug information for port selection mask and
port LUN table bugs in the future. These include renaming refresh_local()
to lookup_local(), tracing the WWN/WWID as a big-endian entity, and
tracing the port selection mask, SCSI channel, and LUN ID each time the
port LUN table is programmed.

Signed-off-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Acked-by: Manoj Kumar <manoj@linux.vnet.ibm.com>
Reviewed-by: Andrew Donnellan <andrew.donnellan@au1.ibm.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
2015-10-30 17:23:55 +09:00
Manoj Kumar
fa4aa632da cxlflash: Fix to avoid invalid port_sel value
If two concurrent MANAGE_LUN ioctls are issued with the same
WWID parameter, it would result in an incorrect value of port_sel.

This is because port_sel is modified without any locks being
held. If the first caller stalls after the return from
find_and_create_lun(), the value of port_sel will be set
incorrectly to indicate a single port, though in this case
it should have been set to both ports.

To fix, use the global mutex to serialize the lookup of the
WWID and the subsequent modification of port_sel.

Signed-off-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: Manoj N. Kumar <manoj@linux.vnet.ibm.com>
Reviewed-by: Brian King <brking@linux.vnet.ibm.com>
Reviewed-by: Tomas Henzl <thenzl@redhat.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
2015-10-30 16:57:21 +09:00
Matthew R. Ochs
2cb79266d6 cxlflash: Virtual LUN support
Add support for physical LUN segmentation (virtual LUNs) to device
driver supporting the IBM CXL Flash adapter. This patch allows user
space applications to virtually segment a physical LUN into N virtual
LUNs, taking advantage of the translation features provided by this
adapter.

Signed-off-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: Manoj N. Kumar <manoj@linux.vnet.ibm.com>
Reviewed-by: Michael Neuling <mikey@neuling.org>
Reviewed-by: Wen Xiong <wenxiong@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
2015-08-26 18:05:39 -07:00
Matthew R. Ochs
65be2c79ac cxlflash: Superpipe support
Add superpipe supporting infrastructure to device driver for the IBM CXL
Flash adapter. This patch allows userspace applications to take advantage
of the accelerated I/O features that this adapter provides and bypass the
traditional filesystem stack.

Signed-off-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: Manoj N. Kumar <manoj@linux.vnet.ibm.com>
Reviewed-by: Michael Neuling <mikey@neuling.org>
Reviewed-by: Wen Xiong <wenxiong@linux.vnet.ibm.com>
Reviewed-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
2015-08-26 18:04:37 -07:00