Due to a typo we would always be using the MIB counter width of the
first element of the counter array instead of the current element, and
we would always be accessing the register statistics with a 64-bits
read, while some could be 32-bits. This got unnoticed in testing with
MDIO and SRAB which tolerate doing this, but testing with the SPI bus
revealed bogus values being returned. Fix this by using the proper
iterator here.
Fixes: 967dd82ffc ("net: dsa: b53: Add support for Broadcom RoboSwitch")
Reported-by: Jonas Gorski <jogo@openwrt.org>
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>
The fixed_phy driver doesn't have to be built-in, and it's
important that of_mdio supports it even if it's a module.
Signed-off-by: Ben Hutchings <ben.hutchings@codethink.co.uk>
Acked-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Dual MAC devices don't necessarily have both MACs wired up, so ignore
those that are disabled.
Signed-off-by: Ben Hutchings <ben.hutchings@codethink.co.uk>
Signed-off-by: David S. Miller <davem@davemloft.net>
Silent ignorance of errors during probe procedure is a bad thing, this
patch fixes it. Extra message added for hardware initialization
failure. Such common issues are mostly caused by wrong wiring. Message
about success added as well, it should be useful to debug new hardware
configuration, especially in case of several CAN buses.
Signed-off-by: Ed Spiridonov <edo.rus@gmail.com>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
As per Wolfgang G, all new drivers should support decreasing state
transition(back-to-error-active). This patch adds this support.
This driver configures the controller to halt on bus-off entry. Hence,
when in error states less than bus off state, the TEC/REC counters
are checked for lower state transition eligibility and action.
Signed-off-by: Ramesh Shanmugasundaram <ramesh.shanmugasundaram@bp.renesas.com>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
The controller can operate in one of the two global modes
- CAN FD only mode (default)
- Classical CAN (CAN2.0) only mode
This patch adds support for Classical CAN only mode. It can be enabled
by defining the optional device tree property "renesas,no-can-fd" of this
node.
Note: R-Car Gen3 h/w manual v0.51E shows bit6 of RSCFDnCFDGCFG as
reserved, which is incorrect. This bit is same as RSCFDnGCFG.
Signed-off-by: Ramesh Shanmugasundaram <ramesh.shanmugasundaram@bp.renesas.com>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
The change to leave out procfs support in CAN when CONFIG_PROC_FS
is not set was incomplete and leads to a build error:
net/built-in.o: In function `can_init':
:(.init.text+0x9858): undefined reference to `can_stat_update'
ERROR: "can_stat_update" [net/can/can.ko] undefined!
This tries a better approach, encapsulating all of the calls
within IS_ENABLED(), so we also leave out the timer function
from the object file.
Signed-off-by: Arnd Bergmann <arnd@arndb.de>
Fixes: a20fadf853 ("can: build proc support only if CONFIG_PROC_FS is activated")
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
The commit f2a4d086ed ("openvswitch: Add packet truncation support.")
introduces packet truncation before sending to userspace upcall receiver.
This patch passes up the skb->len before truncation so that the upcall
receiver knows the original packet size. Potentially this will be used
by sFlow, where OVS translates sFlow config header=N to a sample action,
truncating packet to N byte in kernel datapath. Thus, only N bytes instead
of full-packet size is copied from kernel to userspace, saving the
kernel-to-userspace bandwidth.
Signed-off-by: William Tu <u9012063@gmail.com>
Cc: Pravin Shelar <pshelar@nicira.com>
Acked-by: Pravin B Shelar <pshelar@ovn.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
There are two generics functions phy_ethtool_{get|set}_link_ksettings,
so we can use them instead of defining the same code in the driver.
Signed-off-by: Philippe Reynes <tremyfr@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The private structure contain a pointer to phydev, but the structure
net_device already contain such pointer. So we can remove the pointer
phydev in the private structure, and update the driver to use the
one contained in struct net_device.
Signed-off-by: Philippe Reynes <tremyfr@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
There are two generics functions phy_ethtool_{get|set}_link_ksettings,
so we can use them instead of defining the same code in the driver.
Signed-off-by: Philippe Reynes <tremyfr@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The private structure contain a pointer to phydev, but the structure
net_device already contain such pointer. So we can remove the pointer
phydev in the private structure, and update the driver to use the
one contained in struct net_device.
Signed-off-by: Philippe Reynes <tremyfr@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
There are two generics functions phy_ethtool_{get|set}_link_ksettings,
so we can use them instead of defining the same code in the driver.
Signed-off-by: Philippe Reynes <tremyfr@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The private structure contain a pointer to phydev, but the structure
net_device already contain such pointer. So we can remove the pointer
phydev in the private structure, and update the driver to use the
one contained in struct net_device.
Signed-off-by: Philippe Reynes <tremyfr@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The rxrpc_transport struct is now redundant, given that the rxrpc_peer
struct is now per peer port rather than per peer host, so get rid of it.
Service connection lists are transferred to the rxrpc_peer struct, as is
the conn_lock. Previous patches moved the client connection handling out
of the rxrpc_transport struct and discarded the connection bundling code.
Signed-off-by: David Howells <dhowells@redhat.com>
Kill off the concept of maintaining a bundle of connections to a particular
target service to increase the number of call slots available for any
beyond four for that service (there are four call slots per connection).
This will make cleaning up the connection handling code easier and
facilitate removal of the rxrpc_transport struct. Bundling can be
reintroduced later if necessary.
Signed-off-by: David Howells <dhowells@redhat.com>
Provide refcount helper functions for connections so that the code doesn't
touch local or connection usage counts directly.
Also make it such that local and peer put functions can take a NULL
pointer.
Signed-off-by: David Howells <dhowells@redhat.com>
Make rxrpc_send_packet() take a connection not a transport as part of the
phasing out of the rxrpc_transport struct.
Whilst we're at it, rename the function to rxrpc_send_data_packet() to
differentiate it from the other packet sending functions.
Signed-off-by: David Howells <dhowells@redhat.com>
Allocated rxrpc calls displayed in /proc/net/rxrpc_calls may in future be
on the proc list before they're connected or after they've been
disconnected - in which case they may not have a pointer to a connection
struct that can be used to get data from there.
Deal with this by using stuff from the call struct in preference where
possible and printing "no_connection" rather than a peer address if no
connection is assigned.
This change also has the added bonus that the service ID is now taken from
the call rather the connection which will allow per-call service upgrades
to be shown - something required for AuriStor server compatibility.
Signed-off-by: David Howells <dhowells@redhat.com>
Validate the net address given to rxrpc_kernel_begin_call() before using
it.
Whilst this should be mostly unnecessary for in-kernel users, it does clear
the tail of the address struct in case we want to hash or compare the whole
thing.
Signed-off-by: David Howells <dhowells@redhat.com>
Use the IDR facility to allocate client connection IDs on a machine-wide
basis so that each client connection has a unique identifier. When the
connection ID space wraps, we advance the epoch by 1, thereby effectively
having a 62-bit ID space. The IDR facility is then used to look up client
connections during incoming packet routing instead of using an rbtree
rooted on the transport.
This change allows for the removal of the transport in the future and also
means that client connections can be looked up directly in the data-ready
handler by connection ID.
The ID management code is placed in a new file, conn-client.c, to which all
the client connection-specific code will eventually move.
Note that the IDR tree gets very expensive on memory if the connection IDs
are widely scattered throughout the number space, so we shall need to
retire connections that have, say, an ID more than four times the maximum
number of client conns away from the current allocation point to try and
keep the IDs concentrated. We will also need to retire connections from an
old epoch.
Also note that, for the moment, a pointer to the transport has to be passed
through into the ID allocation function so that we can take a BH lock to
prevent a locking issue against in-BH lookup of client connections. This
will go away later when RCU is used for server connections also.
Signed-off-by: David Howells <dhowells@redhat.com>
rxrpc_connection_lock shouldn't be accessed as a BH-excluding lock. It's
only accessed in a few places and none of those are in BH-context.
rxrpc_transport::conn_lock, however, *is* a BH-excluding lock and should be
accessed so consistently.
Signed-off-by: David Howells <dhowells@redhat.com>
Pass a pointer to struct sk_buff rather than struct rxrpc_host_header to
functions so that they can in the future get at transport protocol parameters
rather than just RxRPC parameters.
Signed-off-by: David Howells <dhowells@redhat.com>
"Exclusive connections" are meant to be used for a single client call and
then scrapped. The idea is to limit the use of the negotiated security
context. The current code, however, isn't doing this: it is instead
restricting the socket to a single virtual connection and doing all the
calls over that.
This is changed such that the socket no longer maintains a special virtual
connection over which it will do all the calls, but rather gets a new one
each time a new exclusive call is made.
Further, using a socket option for this is a poor choice. It should be
done on sendmsg with a control message marker instead so that calls can be
marked exclusive individually. To that end, add RXRPC_EXCLUSIVE_CALL
which, if passed to sendmsg() as a control message element, will cause the
call to be done on an single-use connection.
The socket option (RXRPC_EXCLUSIVE_CONNECTION) still exists and, if set,
will override any lack of RXRPC_EXCLUSIVE_CALL being specified so that
programs using the setsockopt() will appear to work the same.
Signed-off-by: David Howells <dhowells@redhat.com>
Replace accesses of conn->trans->{local,peer} with
conn->params.{local,peer} thus making it easier for a future commit to
remove the rxrpc_transport struct.
This also reduces the number of memory accesses involved.
Signed-off-by: David Howells <dhowells@redhat.com>
Define and use a structure to hold connection parameters. This makes it
easier to pass multiple connection parameters around.
Define and use a structure to hold protocol information used to hash a
connection for lookup on incoming packet. Most of these fields will be
disposed of eventually, including the duplicate local pointer.
Whilst we're at it rename "proto" to "family" when referring to a protocol
family.
Signed-off-by: David Howells <dhowells@redhat.com>
Hashing the peer key was introduced for AF_INET, but gcc
warns about the rxrpc_peer_hash_key function returning uninitialized
data for any other value of srx->transport.family:
net/rxrpc/peer_object.c: In function 'rxrpc_peer_hash_key':
net/rxrpc/peer_object.c:57:15: error: 'p' may be used uninitialized in this function [-Werror=maybe-uninitialized]
Assuming that nothing else can be set here, this changes the
function to just return zero in case of an unknown address
family.
Fixes: be6e6707f6 ("rxrpc: Rework peer object handling to use hash table and RCU")
Signed-off-by: Arnd Bergmann <arnd@arndb.de>
Signed-off-by: David Howells <dhowells@redhat.com>
rxrpc_lookup_peer_rcu() and rxrpc_lookup_peer() return NULL on error, never
error pointers, so IS_ERR() can't be used.
Fix three callers of those functions.
Fixes: be6e6707f6 ('rxrpc: Rework peer object handling to use hash table and RCU')
Signed-off-by: Dan Carpenter <dan.carpenter@oracle.com>
Signed-off-by: David Howells <dhowells@redhat.com>
Jiri Pirko says:
====================
mlxsw: Preparation for IPv4 router
Ido says:
This series prepares the driver for IPv4 router support. The router follow-up
patches are available at: https://github.com/jpirko/linux_mlxsw/tree/net-next_queue
Patches 1-9 simplify the netdevice notification block and also add several
checks during PRECHANGEUPPER events against topologies that aren't supported by
the device. This will ensure L3 interfaces are only configured on top of
valid netdevs.
Patches 10-13 contain trivial changes required for the introduction of a generic
FID struct - currently only used for vFIDs - in patch 14. Making the FID
struct generic will allow us to easily associate the underlying FIDs with
their L3-counterparts - Router interfaces (RIFs):
FID Type | Used by | RIF Type
--------------------------------------------------------
FID | The VLAN-aware bridge | VLAN
vFID | VLAN-unaware bridges | FID
rFID | non-bridged netdevs (follow-up) | Sub-port
Obligatory ASCII art to visualize the above:
A.B.C.D
+
| FID RIF
+
br0 E.F.G.H
+ +
| | VLAN RIF
+---------+---------+ +
| | br1.W
| vFID | +
| | |
vPort +-+-+ +-+-+ +
swXpY.Z | | | | br1
+-+-+ +-+-+ +
| | FID=W |
| | +------------+------------+
| | | |
+---+---+ +---+-+-+ +---+---+
| | | | | |
| | | | | |
| | | | | |
+-------+ +-------+ +-------+
swXpY
Patches 15-16 further generalize the struct by exploiting the fact that the
FID is a shared resource among ports. Each FID type is assigned a 'leave'
function that is invoked based on CHANGEUPPER events and takes care of the
necessary clean-up.
Patches 17-22 build upon the previous patches and use the FID struct for the
VLAN-aware bridge and take care of cleaning up FID resources in the 'leave'
functions. For now, these are only FDB records, but later on we'll have to
remove the RIFs associated with these FIDs, which will in turn take care of
routes and neighbours clean-up.
The last patch adds debug prints that proved very useful during the
development of this series.
Tested with the existing L2 recipes:
https://github.com/jpirko/lnst/tree/master/recipes/switchdev
====================
Signed-off-by: David S. Miller <davem@davemloft.net>
For debug purposes, it's useful to know the order in which the driver
responds to changes in the topology of its upper devices.
Add debug prints to signal these events.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
There are situations in which a vPort is destroyed while still holding
references to device's resources such as FIDs and FDB records. This can
happen, for example, when a VLAN device is deleted while still being
bridged.
Instead of trying to make sure vPort destruction is invoked when it no
longer uses device's resources, just free them upon destruction. This
simplifies the code, as we no longer need to take different situations
into account when events are received - cleanup is taken care of in one
place.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
FDB entries are learned using {Port / LAG ID, FID} and therefore should
be flushed whenever a port (vPort) leaves its FID (vFID).
However, when the bridge port is a LAG device (or a VLAN device on top),
then FDB flushing is conditional. Ports removed from such LAG
configurations must not trigger flushing, as other ports might still be
members in the LAG and therefore the bridge port is still active.
The decision whether to flush or not was previously computed in the
netdevice notification block, but in order to flush the entries when a
port leaves its FID this decision should be computed there.
Strip the notification block from this logic and instead move it to one
FDB flushing function that is invoked from both the FID / vFID leave
functions.
When port isn't member in LAG, FDB flushing should always occur.
Otherwise, it should occur only when the last port (vPort) member in the
LAG leaves the FID (vFID).
This will allow us - in the next patch - to simplify the cleanup code
paths that are hit whenever the topology above the port netdevs changes.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Not all vPorts will have FIDs assigned to them, so make sure functions
first test for FID presence.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
As previously explained, not all vPorts will be assigned FIDs, so instead
of returning the FID index of a vPort, return a pointer to its FID
struct. This will allow us to know whether it's legal to access the
vPort's FID parameters such as index and device.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
When L3 interfaces will be introduced a vPort won't necessarily have a
FID assigned to it. This can happen if it's not member in a bridge (in
which case it's assigned a vFID) or doesn't have an IP address (in which
case it's assigned an rFID).
Therefore, instead check the VID parameter to test whether a port is a
vPort or not.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
In a very similar way to the vFIDs, make the first 4K FIDs - used in the
VLAN-aware bridge - use the new FID struct.
Upon first use of the FID by any of the ports do the following:
1) Create the FID
2) Setup a matching flooding entry
3) Create a mapping for the FID
Unlike vFIDs, upon creation of a FID we always create a global
VID-to-FID mapping, so that ports without upper vPorts can use it
instead of creating an explicit {Port, VID} to FID mapping.
When a port leaves a FID the reverse is performed. Whenever the FID's
reference count reaches zero the FID is deleted along with the global
mapping.
The per-FID struct will later allow us to configure L3 interfaces on top
of the VLAN-aware bridge.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
When a vPort is created or when it joins a bridge we always do the same
set of operations:
1) Create the vFID, if not already created
2) Setup flooding for the vFID
3) Map the {Port, VID} to the vFID
When a vPort is destroyed or when it leaves a bridge the reverse is
performed.
Encapsulate the above in join / leave functions and simplify the code.
FIDs and rFIDs will use a similar set of functions.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Up until now we had a dedicated struct only for vFIDs, but before
introducing support for L3 interfaces we need to make it generic and
use it for all three types of FIDs:
1) FIDs - 0..4K-1, used for the VLAN-aware bridge
2) vFIDs - 4K..15K-1, used for VLAN-unaware bridges
3) rFIDs - 15K..16K-1, used to direct traffic to / from the router in
the device. Will be introduced later in the series.
The three types of L3 interfaces - Router InterFaces, RIFs - that will
be introduced correspond to the three types of FIDs and are configured
using them. Therefore, we'll need to store the links between them as
well as a reference count on the underlying FID, so that the
corresponding RIF will be destroyed when it reaches zero.
Note that the lower 0.5K vFIDs are currently used for for non-bridged
netdevs, so that traffic could be flooded to the CPU port. However, when
rFIDs will be introduced we'll no longer need these and they too will be
used for VLAN-unaware bridges.
Make the vFID struct generic by renaming it and some of its fields. FIDs
will be converted to use it later in the series.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Use a FID index instead of vFID and ease the transition towards a
generic FID struct.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
A FID used by a vPort (vFID, but also rFID later in the series) is
always mapped using {Port, VID} and not only VID as with the 4K FIDs of
the VLAN-aware bridge.
Instead of specifying all the arguments each time, just wrap this
operation using a dedicated function and simplify the code.
As before, the function takes FID as its argument in preparation for a
generic FID struct.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Simplify the code and use only one function for vFID creation /
destruction.
Unlike before, the function receives a FID index as its argument and not
a vFID index. Instead of passing 0, now one would need to pass 4K, which
is the first vFID.
This is the first step in creating a generic FID struct that will be
used for all three types of FIDs.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
In all call sites 'only_uc' is set to false, so strip it.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
There is a macro to do this kind of declarations, so use it.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
We hold a reference count on the number of ports member in the
VLAN-aware bridge, as we only support one.
Instead of always incrementing / decrementing the reference count after
joining / leaving the bridge, simply do this accounting in the join /
leave functions.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The argument 'br_dev' is never used, so remove it.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
When responding to unlinking CHANGEUPPER notifications we shouldn't
return any value, as it's not checked by upper layers.
In addition, there's nothing the driver can do in case of failure, so it
should simply continue and try to free as much resources as possible and
not stop on first error.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Instead of checking for a condition and then issue the warning, just do
it in one go and simplify the code.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
When upper device of a VLAN device changes we already made sure it's
a bridge device in PRECHANGEUPPER, so no need to check it's a master
device in CHANGEUPPER.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
When a port netdev is put under LAG it cannot have VLAN upper devices,
so forbid that. The LAG device itself can have VLAN upper devices.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>