In this patch if le_create_conn process is started restrict to
disable address resolution and same is disabled during
le_enh_connection_complete
Signed-off-by: Sathish Narasimman <sathish.narasimman@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
When using controller based address resolution, then the new address
types 0x02 and 0x03 are used. These types need to be converted back into
either public address or random address types.
This patch is specially during LE_CREATE_CONN if using own_add_type as 0x02
or 0x03.
Signed-off-by: Sathish Narasimman <sathish.narasimman@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Check `num_rsp` before using it as for-loop counter. Add `unlock` label.
Cc: stable@vger.kernel.org
Signed-off-by: Peilin Ye <yepeilin.cs@gmail.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Check `num_rsp` before using it as for-loop counter.
Cc: stable@vger.kernel.org
Signed-off-by: Peilin Ye <yepeilin.cs@gmail.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This calls hci_update_background_scan() when there is any update on the
advertisement monitors. If there is at least one advertisement monitor,
the filtering policy of scan parameters should be 0x00. This also reports
device found mgmt events if there is at least one monitor.
The following cases were tested with btmgmt advmon-* commands.
(1) add a ADV monitor and observe that the passive scanning is
triggered.
(2) remove the last ADV monitor and observe that the passive scanning is
terminated.
(3) with a LE peripheral paired, repeat (1) and observe the passive
scanning continues.
(4) with a LE peripheral paired, repeat (2) and observe the passive
scanning continues.
(5) with a ADV monitor, suspend/resume the host and observe the passive
scanning continues.
Signed-off-by: Miao-chen Chou <mcchou@chromium.org>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
In order to more easily add device flags to classic devices, create
a new type of bdaddr_list that supports setting flags.
Signed-off-by: Abhishek Pandit-Subedi <abhishekpandit@chromium.org>
Reviewed-by: Alain Michaud <alainm@chromium.org>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
This makes hci_encrypt_cfm calls hci_connect_cfm in case the connection
state is BT_CONFIG so callers don't have to check the state.
Signed-off-by: Luiz Augusto von Dentz <luiz.von.dentz@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Bluetooth PTS test case HFP/AG/ACC/BI-12-I accepts SCO connection
with invalid parameter at the first SCO request expecting AG to
attempt another SCO request with the use of "safe settings" for
given codec, base on section 5.7.1.2 of HFP 1.7 specification.
This patch addresses it by adding "Invalid LMP Parameters" (0x1e)
to the SCO fallback case. Verified with below log:
< HCI Command: Setup Synchronous Connection (0x01|0x0028) plen 17
Handle: 256
Transmit bandwidth: 8000
Receive bandwidth: 8000
Max latency: 13
Setting: 0x0003
Input Coding: Linear
Input Data Format: 1's complement
Input Sample Size: 8-bit
# of bits padding at MSB: 0
Air Coding Format: Transparent Data
Retransmission effort: Optimize for link quality (0x02)
Packet type: 0x0380
3-EV3 may not be used
2-EV5 may not be used
3-EV5 may not be used
> HCI Event: Command Status (0x0f) plen 4
Setup Synchronous Connection (0x01|0x0028) ncmd 1
Status: Success (0x00)
> HCI Event: Number of Completed Packets (0x13) plen 5
Num handles: 1
Handle: 256
Count: 1
> HCI Event: Max Slots Change (0x1b) plen 3
Handle: 256
Max slots: 1
> HCI Event: Synchronous Connect Complete (0x2c) plen 17
Status: Invalid LMP Parameters / Invalid LL Parameters (0x1e)
Handle: 0
Address: 00:1B:DC:F2:21:59 (OUI 00-1B-DC)
Link type: eSCO (0x02)
Transmission interval: 0x00
Retransmission window: 0x02
RX packet length: 0
TX packet length: 0
Air mode: Transparent (0x03)
< HCI Command: Setup Synchronous Connection (0x01|0x0028) plen 17
Handle: 256
Transmit bandwidth: 8000
Receive bandwidth: 8000
Max latency: 8
Setting: 0x0003
Input Coding: Linear
Input Data Format: 1's complement
Input Sample Size: 8-bit
# of bits padding at MSB: 0
Air Coding Format: Transparent Data
Retransmission effort: Optimize for link quality (0x02)
Packet type: 0x03c8
EV3 may be used
2-EV3 may not be used
3-EV3 may not be used
2-EV5 may not be used
3-EV5 may not be used
> HCI Event: Command Status (0x0f) plen 4
Setup Synchronous Connection (0x01|0x0028) ncmd 1
Status: Success (0x00)
> HCI Event: Max Slots Change (0x1b) plen 3
Handle: 256
Max slots: 5
> HCI Event: Max Slots Change (0x1b) plen 3
Handle: 256
Max slots: 1
> HCI Event: Synchronous Connect Complete (0x2c) plen 17
Status: Success (0x00)
Handle: 257
Address: 00:1B:DC:F2:21:59 (OUI 00-1B-DC)
Link type: eSCO (0x02)
Transmission interval: 0x06
Retransmission window: 0x04
RX packet length: 30
TX packet length: 30
Air mode: Transparent (0x03)
Signed-off-by: Hsin-Yu Chao <hychao@chromium.org>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
After sending Inquiry Cancel command to the controller, it is possible
that Inquiry Complete event comes before Inquiry Cancel command complete
event. In this case the Inquiry Cancel command will have status of
Command Disallowed since there is no Inquiry session to be cancelled.
This case should not be treated as error, otherwise we can reach an
inconsistent state.
Example of a btmon trace when this happened:
< HCI Command: Inquiry Cancel (0x01|0x0002) plen 0
> HCI Event: Inquiry Complete (0x01) plen 1
Status: Success (0x00)
> HCI Event: Command Complete (0x0e) plen 4
Inquiry Cancel (0x01|0x0002) ncmd 1
Status: Command Disallowed (0x0c)
Signed-off-by: Sonny Sasaka <sonnysasaka@chromium.org>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This change allows scatternet connections to be created if the
controller reports support and the HCI_QUIRK_VALID_LE_STATES indicates
that the reported LE states can be trusted.
Signed-off-by: Alain Michaud <alainm@chromium.org>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
The error could indicate a problem with the Bluetooth device. It
is easier to investigate if the packet's actual length gets logged,
not just the fact that a discrepancy occurred.
Signed-off-by: Daniels Umanovskis <du@axentia.se>
Reviewed-by: Alain Michaud <alainm@chromium.org>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
With the Read Local Simple Pairing Options command it is possible to
retrieve the support for max encryption key size supported by the
controller and also if the controller correctly verifies the ECDH public
key during pairing.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Reviewed-by: Alain Michaud <alainm@chromium.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Micrsoft defined a set for HCI vendor extensions. Check the following
link for details:
https://docs.microsoft.com/en-us/windows-hardware/drivers/bluetooth/microsoft-defined-bluetooth-hci-commands-and-events
This provides the basic framework to enable the extension and read its
supported features. Drivers still have to declare support for this
extension before it can be utilized by the host stack.
Signed-off-by: Miao-chen Chou <mcchou@chromium.org>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
notifying using HCI_NOTIFY_CONN_ADD for SCO connection is generic in
case of mSBC audio. To differntiate SCO air mode introducing
HCI_NOTIFY_ENABLE_SCO_CVSD and HCI_NOTIFY_ENABLE_SCO_TRANSP.
Signed-off-by: Sathish Narsimman <sathish.narasimman@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
With this change, the encryption key size is not assumed to be 16 if the
read_encryption_key_size command fails for any reason. This ensures
that if the controller fails the command for any reason that the
encryption key size isn't implicitely set to 16 and instead take a more
concervative posture to assume it is 0.
Signed-off-by: Alain Michaud <alainm@chromium.org>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
When handling auto-connected devices, we should execute the rest of the
connection complete when it was previously discovered and it is an ACL
connection.
Signed-off-by: Abhishek Pandit-Subedi <abhishekpandit@chromium.org>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
In bluetooth core specification 4.2,
Vol 2, Part E, 7.8.9 LE Set Advertise Enable Command, it says
The Controller shall continue advertising until ...
or until a connection is created or ...
In these cases, advertising is then disabled.
Hence, advertising would be disabled before a connection is
established. In current kernel implementation, advertising would
be re-enabled when all connections are terminated.
The correct disconnection flow looks like
< HCI Command: Disconnect
> HCI Event: Command Status
Status: Success
> HCI Event: Disconnect Complete
Status: Success
Specifically, the last Disconnect Complete Event would trigger a
callback function hci_event.c:hci_disconn_complete_evt() to
cleanup the connection and re-enable advertising when proper.
However, sometimes, there might occur an exception in the controller
when disconnection is being executed. The disconnection flow might
then look like
< HCI Command: Disconnect
> HCI Event: Command Status
Status: Unknown Connection Identifier
Note that "> HCI Event: Disconnect Complete" is missing when such an
exception occurs. This would result in advertising staying disabled
forever since the connection in question is not cleaned up correctly.
To fix the controller exception issue, we need to do some connection
cleanup when the disconnect command status indicates an error.
Signed-off-by: Joseph Hwang <josephsih@chromium.org>
Signed-off-by: Manish Mandlik <mmandlik@google.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
To handle BR/EDR devices, we first disable page scan and disconnect all
connected devices. Once that is complete, we add event filters (for
devices that can wake the system) and re-enable page scan.
Signed-off-by: Abhishek Pandit-Subedi <abhishekpandit@chromium.org>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This change introduces a wide band speech setting which allows higher
level clients to query the local controller support for wide band speech
as well as set the setting state when the radio is powered off.
Internally, this setting controls if erroneous data reporting is enabled
on the controller.
Signed-off-by: Alain Michaud <alainm@chromium.org>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Some controllers have been observed to send zero'd events under some
conditions. This change guards against this condition as well as adding
a trace to facilitate diagnosability of this condition.
Signed-off-by: Alain Michaud <alainm@chromium.org>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Attack scenario:
1. A Chromebook (let's call this device A) is paired to a legitimate
Bluetooth classic device (e.g. a speaker) (let's call this device
B).
2. A malicious device (let's call this device C) pretends to be the
Bluetooth speaker by using the same BT address.
3. If device A is not currently connected to device B, device A will
be ready to accept connection from device B in the background
(technically, doing Page Scan).
4. Therefore, device C can initiate connection to device A
(because device A is doing Page Scan) and device A will accept the
connection because device A trusts device C's address which is the
same as device B's address.
5. Device C won't be able to communicate at any high level Bluetooth
profile with device A because device A enforces that device C is
encrypted with their common Link Key, which device C doesn't have.
But device C can initiate pairing with device A with just-works
model without requiring user interaction (there is only pairing
notification). After pairing, device A now trusts device C with a
new different link key, common between device A and C.
6. From now on, device A trusts device C, so device C can at anytime
connect to device A to do any kind of high-level hijacking, e.g.
speaker hijack or mouse/keyboard hijack.
Since we don't know whether the repairing is legitimate or not,
leave the decision to user space if all the conditions below are met.
- the pairing is initialized by peer
- the authorization method is just-work
- host already had the link key to the peer
Signed-off-by: Howard Chung <howardchung@google.com>
Acked-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This handles LE PHY Update Complete event and store both tx_phy and
rx_phy into hci_conn.
Signed-off-by: Luiz Augusto von Dentz <luiz.von.dentz@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
The macro is really not needed and can be replaced with either usage of
bt_err_ratelimited or bt_dev_err_ratelimited.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
This reverts commit c49a8682fc.
There are devices which require low connection intervals for usable operation
including keyboards and mice. Forcing a static connection interval for
these types of devices has an impact in latency and causes a regression.
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Problem: The Linux Bluetooth stack yields complete control over the BLE
connection interval to the remote device.
The Linux Bluetooth stack provides access to the BLE connection interval
min and max values through /sys/kernel/debug/bluetooth/hci0/
conn_min_interval and /sys/kernel/debug/bluetooth/hci0/conn_max_interval.
These values are used for initial BLE connections, but the remote device
has the ability to request a connection parameter update. In the event
that the remote side requests to change the connection interval, the Linux
kernel currently only validates that the desired value is within the
acceptable range in the Bluetooth specification (6 - 3200, corresponding to
7.5ms - 4000ms). There is currently no validation that the desired value
requested by the remote device is within the min/max limits specified in
the conn_min_interval/conn_max_interval configurations. This essentially
leads to Linux yielding complete control over the connection interval to
the remote device.
The proposed patch adds a verification step to the connection parameter
update mechanism, ensuring that the desired value is within the min/max
bounds of the current connection. If the desired value is outside of the
current connection min/max values, then the connection parameter update
request is rejected and the negative response is returned to the remote
device. Recall that the initial connection is established using the local
conn_min_interval/conn_max_interval values, so this allows the Linux
administrator to retain control over the BLE connection interval.
The one downside that I see is that the current default Linux values for
conn_min_interval and conn_max_interval typically correspond to 30ms and
50ms respectively. If this change were accepted, then it is feasible that
some devices would no longer be able to negotiate to their desired
connection interval values. This might be remedied by setting the default
Linux conn_min_interval and conn_max_interval values to the widest
supported range (6 - 3200 / 7.5ms - 4000ms). This could lead to the same
behavior as the current implementation, where the remote device could
request to change the connection interval value to any value that is
permitted by the Bluetooth specification, and Linux would accept the
desired value.
Signed-off-by: Carey Sonsino <csonsino@gmail.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Changes made to add HCI Write Authenticated Payload timeout
command for LE Ping feature.
As per the Core Specification 5.0 Volume 2 Part E Section 7.3.94,
the following code changes implements
HCI Write Authenticated Payload timeout command for LE Ping feature.
Signed-off-by: Spoorthi Ravishankar Koppad <spoorthix.k@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This commit makes the kernel not send the next queued HCI command until
a command complete arrives for the last HCI command sent to the
controller. This change avoids a problem with some buggy controllers
(seen on two SKUs of QCA9377) that send an extra command complete event
for the previous command after the kernel had already sent a new HCI
command to the controller.
The problem was reproduced when starting an active scanning procedure,
where an extra command complete event arrives for the LE_SET_RANDOM_ADDR
command. When this happends the kernel ends up not processing the
command complete for the following commmand, LE_SET_SCAN_PARAM, and
ultimately behaving as if a passive scanning procedure was being
performed, when in fact controller is performing an active scanning
procedure. This makes it impossible to discover BLE devices as no device
found events are sent to userspace.
This problem is reproducible on 100% of the attempts on the affected
controllers. The extra command complete event can be seen at timestamp
27.420131 on the btmon logs bellow.
Bluetooth monitor ver 5.50
= Note: Linux version 5.0.0+ (x86_64) 0.352340
= Note: Bluetooth subsystem version 2.22 0.352343
= New Index: 80:C5:F2:8F:87:84 (Primary,USB,hci0) [hci0] 0.352344
= Open Index: 80:C5:F2:8F:87:84 [hci0] 0.352345
= Index Info: 80:C5:F2:8F:87:84 (Qualcomm) [hci0] 0.352346
@ MGMT Open: bluetoothd (privileged) version 1.14 {0x0001} 0.352347
@ MGMT Open: btmon (privileged) version 1.14 {0x0002} 0.352366
@ MGMT Open: btmgmt (privileged) version 1.14 {0x0003} 27.302164
@ MGMT Command: Start Discovery (0x0023) plen 1 {0x0003} [hci0] 27.302310
Address type: 0x06
LE Public
LE Random
< HCI Command: LE Set Random Address (0x08|0x0005) plen 6 #1 [hci0] 27.302496
Address: 15:60:F2:91:B2:24 (Non-Resolvable)
> HCI Event: Command Complete (0x0e) plen 4 #2 [hci0] 27.419117
LE Set Random Address (0x08|0x0005) ncmd 1
Status: Success (0x00)
< HCI Command: LE Set Scan Parameters (0x08|0x000b) plen 7 #3 [hci0] 27.419244
Type: Active (0x01)
Interval: 11.250 msec (0x0012)
Window: 11.250 msec (0x0012)
Own address type: Random (0x01)
Filter policy: Accept all advertisement (0x00)
> HCI Event: Command Complete (0x0e) plen 4 #4 [hci0] 27.420131
LE Set Random Address (0x08|0x0005) ncmd 1
Status: Success (0x00)
< HCI Command: LE Set Scan Enable (0x08|0x000c) plen 2 #5 [hci0] 27.420259
Scanning: Enabled (0x01)
Filter duplicates: Enabled (0x01)
> HCI Event: Command Complete (0x0e) plen 4 #6 [hci0] 27.420969
LE Set Scan Parameters (0x08|0x000b) ncmd 1
Status: Success (0x00)
> HCI Event: Command Complete (0x0e) plen 4 #7 [hci0] 27.421983
LE Set Scan Enable (0x08|0x000c) ncmd 1
Status: Success (0x00)
@ MGMT Event: Command Complete (0x0001) plen 4 {0x0003} [hci0] 27.422059
Start Discovery (0x0023) plen 1
Status: Success (0x00)
Address type: 0x06
LE Public
LE Random
@ MGMT Event: Discovering (0x0013) plen 2 {0x0003} [hci0] 27.422067
Address type: 0x06
LE Public
LE Random
Discovery: Enabled (0x01)
@ MGMT Event: Discovering (0x0013) plen 2 {0x0002} [hci0] 27.422067
Address type: 0x06
LE Public
LE Random
Discovery: Enabled (0x01)
@ MGMT Event: Discovering (0x0013) plen 2 {0x0001} [hci0] 27.422067
Address type: 0x06
LE Public
LE Random
Discovery: Enabled (0x01)
Signed-off-by: João Paulo Rechi Vita <jprvita@endlessm.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
In ext_adv_report_event rssi comes before data (not after data as
in legacy adv_report_evt) so "+ 1" is not required in the ptr arithmatic
to point to next report.
Signed-off-by: Jaganath Kanakkassery <jaganath.kanakkassery@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Make use of the struct_size() helper instead of an open-coded version
in order to avoid any potential type mistakes, in particular in the
context in which this code is being used.
So, change the following form:
sizeof(*ev) + ev->num_hndl * sizeof(struct hci_comp_pkts_info)
to :
struct_size(ev, handles, ev->num_hndl)
This code was detected with the help of Coccinelle.
Signed-off-by: Gustavo A. R. Silva <gustavo@embeddedor.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
In case a command which completes in Command Status was sent using the
hci_cmd_send-family of APIs there would be a misleading error in the
hci_get_cmd_complete function, since the code would be trying to fetch
the Command Complete parameters when there are none.
Avoid the misleading error and silently bail out from the function in
case the received event is a command status.
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Acked-by: Luiz Augusto von Dentz <luiz.von.dentz@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
The check on status is redundant as a status has to be zero at
the point it is being checked because of a previous check and return
path via label 'unlock'. Remove the redundant check and the deadcode
that can never be reached.
Detected by CoverityScan, CID#1471710 ("Logically dead code")
Signed-off-by: Colin Ian King <colin.king@canonical.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Add the definitions for adding entries to the LE resolve list and
removing entries from the LE resolve list. When the LE resolve list
gets changed via HCI commands make sure that the internal storage of
the resolve list entries gets updated.
Signed-off-by: Ankit Navik <ankit.p.navik@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Add the definitions for LE address resolution enable HCI commands.
When the LE address resolution enable gets changed via HCI commands
make sure that flag gets updated.
Signed-off-by: Ankit Navik <ankit.p.navik@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
Variables 'adv_set' and 'cp' are being assigned but are never used hence
they are redundant and can be removed.
Cleans up clang warnings:
net/bluetooth/hci_event.c:1135:29: warning: variable 'adv_set' set but not used [-Wunused-but-set-variable]
net/bluetooth/mgmt.c:3359:39: warning: variable 'cp' set but not used [-Wunused-but-set-variable]
Signed-off-by: YueHaibing <yuehaibing@huawei.com>
Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
This event comes after connection complete event for incoming
connections. Since we now have different random address for
each instance, conn resp address is assigned from this event.
As of now only connection part is handled as we are not
enabling duration or max num of events while starting ext adv.
Signed-off-by: Jaganath Kanakkassery <jaganathx.kanakkassery@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This basically sets the random address for the adv instance
Random address can be set only if the instance is created which
is done in Set ext adv param.
Random address and rpa expire timer and flags have been added
to adv instance which will be used when the respective
instance is scheduled.
This introduces a hci_get_random_address() which returns the
own address type and random address (rpa or nrpa) based
on the instance flags and hdev flags. New function is required
since own address type should be known before setting adv params
but address can be set only after setting params.
< HCI Command: LE Set Advertising Set Random Address (0x08|0x0035) plen 7
Advertising handle: 0x00
Advertising random address: 3C:8E:56:9B:77:84 (OUI 3C-8E-56)
> HCI Event: Command Complete (0x0e) plen 4
LE Set Advertising Set Random Address (0x08|0x0035) ncmd 1
Status: Success (0x00)
Signed-off-by: Jaganath Kanakkassery <jaganathx.kanakkassery@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
If ext adv is enabled then use ext adv to disable as well.
Also remove the adv set during LE disable.
< HCI Command: LE Set Extended Advertising Enable (0x08|0x0039) plen 2
Extended advertising: Disabled (0x00)
Number of sets: Disable all sets (0x00)
> HCI Event: Command Complete (0x0e) plen 4
LE Set Extended Advertising Enable (0x08|0x0039) ncmd 2
Status: Success (0x00)
Signed-off-by: Jaganath Kanakkassery <jaganathx.kanakkassery@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This patch implements Set Ext Adv data and Set Ext Scan rsp data
if controller support extended advertising.
Currently the operation is set as Complete data and fragment
preference is set as no fragment
< HCI Command: LE Set Extended Advertising Data (0x08|0x0037) plen 35
Handle: 0x00
Operation: Complete extended advertising data (0x03)
Fragment preference: Minimize fragmentation (0x01)
Data length: 0x15
16-bit Service UUIDs (complete): 2 entries
Heart Rate (0x180d)
Battery Service (0x180f)
Name (complete): Test LE
Company: Google (224)
Data: 0102
> HCI Event: Command Complete (0x0e) plen 4
LE Set Extended Advertising Data (0x08|0x0037) ncmd 1
Status: Success (0x00)
Signed-off-by: Jaganath Kanakkassery <jaganathx.kanakkassery@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This patch basically replaces legacy adv with extended adv
based on the controller support. Currently there is no
design change. ie only one adv set will be enabled at a time.
This also adds tx_power in instance and store whatever returns
from Set_ext_parameter, use the same in adv data as well.
For instance 0 tx_power is stored in hdev only.
< HCI Command: LE Set Extended Advertising Parameters (0x08|0x0036) plen 25
Handle: 0x00
Properties: 0x0010
Use legacy advertising PDUs: ADV_NONCONN_IND
Min advertising interval: 1280.000 msec (0x0800)
Max advertising interval: 1280.000 msec (0x0800)
Channel map: 37, 38, 39 (0x07)
Own address type: Random (0x01)
Peer address type: Public (0x00)
Peer address: 00:00:00:00:00:00 (OUI 00-00-00)
Filter policy: Allow Scan Request from Any, Allow Connect Request from Any (0x00)
TX power: 127 dbm (0x7f)
Primary PHY: LE 1M (0x01)
Secondary max skip: 0x00
Secondary PHY: LE 1M (0x01)
SID: 0x00
Scan request notifications: Disabled (0x00)
> HCI Event: Command Complete (0x0e) plen 5
LE Set Extended Advertising Parameters (0x08|0x0036) ncmd 1
Status: Success (0x00)
TX power (selected): 7 dbm (0x07)
< HCI Command: LE Set Extended Advertising Enable (0x08|0x0039) plen 6
Extended advertising: Enabled (0x01)
Number of sets: 1 (0x01)
Entry 0
Handle: 0x00
Duration: 0 ms (0x00)
Max ext adv events: 0
> HCI Event: Command Complete (0x0e) plen 4
LE Set Extended Advertising Enable (0x08|0x0039) ncmd 2
Status: Success (0x00)
Signed-off-by: Jaganath Kanakkassery <jaganathx.kanakkassery@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This patch reads the number of advertising sets in the controller
during init and save it in hdev.
Signed-off-by: Jaganath Kanakkassery <jaganathx.kanakkassery@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This patch defines the extended ADV types and handle it in ADV report.
Signed-off-by: Jaganath Kanakkassery <jaganathx.kanakkassery@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This implements extended LE craete connection and enhanced
LE conn complete event if the controller supports.
For now it is as good as legacy LE connection and event as
no new features in the extended connection is handled.
< HCI Command: LE Extended Create Connection (0x08|0x0043) plen 26
Filter policy: White list is not used (0x00)
Own address type: Public (0x00)
Peer address type: Random (0x01)
Peer address: DB:7E:2E:1D:85:E8 (Static)
Initiating PHYs: 0x01
Entry 0: LE 1M
Scan interval: 60.000 msec (0x0060)
Scan window: 60.000 msec (0x0060)
Min connection interval: 50.00 msec (0x0028)
Max connection interval: 70.00 msec (0x0038)
Connection latency: 0 (0x0000)
Supervision timeout: 420 msec (0x002a)
Min connection length: 0.000 msec (0x0000)
Max connection length: 0.000 msec (0x0000)
> HCI Event: Command Status (0x0f) plen 4
LE Extended Create Connection (0x08|0x0043) ncmd 2
Status: Success (0x00)
> HCI Event: LE Meta Event (0x3e) plen 31
LE Enhanced Connection Complete (0x0a)
Status: Success (0x00)
Handle: 3585
Role: Master (0x00)
Peer address type: Random (0x01)
Peer address: DB:7E:2E:1D:85:E8 (Static)
Local resolvable private address: 00:00:00:00:00:00 (Non-Resolvable)
Peer resolvable private address: 00:00:00:00:00:00 (Non-Resolvable)
Connection interval: 67.50 msec (0x0036)
Connection latency: 0 (0x0000)
Supervision timeout: 420 msec (0x002a)
Master clock accuracy: 0x00
@ MGMT Event: Device Connected (0x000b) plen 40
LE Address: DB:7E:2E:1D:85:E8 (Static)
Flags: 0x00000000
Data length: 27
Name (complete): Designer Mouse
Appearance: Mouse (0x03c2)
Flags: 0x05
LE Limited Discoverable Mode
BR/EDR Not Supported
16-bit Service UUIDs (complete): 1 entry
Human Interface Device (0x1812)
Signed-off-by: Jaganath Kanakkassery <jaganathx.kanakkassery@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This is done so that the helpers can be used for extended conn
implementation which will be done in subsequent patch.
Signed-off-by: Jaganath Kanakkassery <jaganathx.kanakkassery@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
This patch enables Extended ADV report event if extended scanning
is supported in the controller and process the same.
The new features are not handled and for now its as good as
legacy ADV report.
> HCI Event: LE Meta Event (0x3e) plen 53
LE Extended Advertising Report (0x0d)
Num reports: 1
Entry 0
Event type: 0x0013
Props: 0x0013
Connectable
Scannable
Use legacy advertising PDUs
Data status: Complete
Legacy PDU Type: ADV_IND (0x0013)
Address type: Random (0x01)
Address: DB:7E:2E:1A:85:E8 (Static)
Primary PHY: LE 1M
Secondary PHY: LE 1M
SID: 0x00
TX power: 0 dBm
RSSI: -90 dBm (0xa6)
Periodic advertising invteral: 0.00 msec (0x0000)
Direct address type: Public (0x00)
Direct address: 00:00:00:00:00:00 (OUI 00-00-00)
Data length: 0x1b
0f 09 44 65 73 69 67 6e 65 72 20 4d 6f 75 73 65 ..Designer Mouse
03 19 c2 03 02 01 05 03 03 12 18 ...........
Signed-off-by: Jaganath Kanakkassery <jaganathx.kanakkassery@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>